文献速递心血管CT

低管电压前瞻性心电触发冠状动脉CT血管成像:图像质量与辐射剂量的系统综述

Low tube voltage prospectively ECG-triggered coronary CT angiography: a systematic review of image quality and radiation dose.
PubMed 文献 · Br J Radiol · 2018-03-29

该系统综述纳入20项研究,分析前瞻性心电触发低管电压冠状动脉CT血管成像的扫描参数与对比剂优化方法。80 kVp与100 kVp下平均有效剂量分别为0.31至2.75 mSv与0.69至6.29 mSv,120 kVp为1.53至10.7 mSv;80 kVp和100 kVp分别可实现38%至83%和3%至80%的辐射剂量降低而保持图像质量。

要点

  • 80 kVp下平均有效剂量0.31至2.75 mSv,100 kVp下0.69至6.29 mSv,120 kVp下1.53至10.7 mSv。
  • 80 kVp可实现38%至83%的辐射剂量降低,100 kVp可实现3%至80%的降低,且保持图像质量。
  • 80 kVp下采用碘输送率1.35至1.45 g/s、总碘量10.9至16.2 g可获得与120 kVp相似的血管对比增强。

核心结论

  • 该系统综述发现,80 kVp下辐射剂量可降低38%至83%,100 kVp下可降低3%至80%,且不损害图像质量。

研究设计与样本

  • 系统综述,检索PubMed、Cochrane图书馆、CINAHL、Web of Science、ScienceDirect和Scopus,纳入20项研究分析扫描参数与对比剂优化方法。

诊断标准与关键数值

  • 80 kVp下平均有效剂量0.31至2.75 mSv,100 kVp下0.69至6.29 mSv,120 kVp下1.53至10.7 mSv;80 kVp下碘输送率1.35至1.45 g/s、总碘量10.9至16.2 g可获与120 kVp相似的血管对比增强;100 kVp下碘输送率1.08至1.70 g/s、总碘量18.9至20.9 g可获相似增强。

临床应用与阅片要点

  • 作者提出,所建议的合适扫描参数与对比剂优化方法可帮助使用者在降低辐射剂量的同时获得诊断级图像质量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed (1) to perform a systematic review on scanning parameters and contrast medium (CM) reduction methods used in prospectively electrocardiography (ECG-triggered low tube voltage coronary CT angiography (CCTA), (2) to compare the achievable dose reduction and image quality and (3) to propose appropriate scanning techniques and CM administration methods.

METHODS: A systematic search was performed in PubMed, the Cochrane library, CINAHL, Web of Science, ScienceDirect and Scopus, where 20 studies were selected for analysis of scanning parameters and CM reduction methods.

RESULTS: The mean effective dose (HE) ranged from 0.31 to 2.75 mSv at 80 kVp, 0.69 to 6.29 mSv at 100 kVp and 1.53 to 10.7 mSv at 120 kVp. Radiation dose reductions of 38 to 83% at 80 kVp and 3 to 80% at 100 kVp could be achieved with preserved image quality. Similar vessel contrast enhancement to 120 kVp could be obtained by applying iodine delivery rate (IDR) of 1.35 to 1.45 g s-1 with total iodine dose (TID) of between 10.9 and 16.2 g at 80 kVp and IDR of 1.08 to 1.70 g s-1 with TID of between 18.9 and 20.9 g at 100 kVp.

CONCLUSION: This systematic review found that radiation doses could be reduced to a rate of 38 to 83% at 80 kVp, and 3 to 80% at 100 kVp without compromising the image quality. Advances in knowledge: The suggested appropriate scanning parameters and CM reduction methods can be used to help users in achieving diagnostic image quality with reduced radiation dose.

来源:Br J Radiol,查看原文。版权归原作者所有。