HeartWare左心室辅助装置患者血流动力学状态的无创评估:一种超声心动图方法的验证
这项前瞻性研究在35例HeartWare左心室辅助装置(HVAD)患者中验证了一种超声心动图方案,用于无创评估右心房压和左心房压。超声估测的右心房压和左心房压与有创测值显著相关(r分别为0.839和0.889,P均<0.001),检测高右心房压和高左心房压的曲线下面积分别为0.94和0.91(P均<0.001)。高估测右心房压与高楔压相关,并与180天死亡或住院相关(比值比8.2,95%CI 1.1–21.0,P=0.04)。
要点
- 超声估测右心房压与有创右心房压显著相关(r=0.839,P<0.001),检测高右心房压的曲线下面积为0.94。
- 超声估测左心房压与有创左心房压显著相关(r=0.889,P<0.001),检测高左心房压的曲线下面积为0.91。
- 高估测右心房压与高楔压相关(曲线下面积0.92,P<0.001),并与180天死亡或住院相关(比值比8.2)。
核心结论
- 多普勒超声心动图能准确估测HVAD患者的血流动力学状态,该方案可可靠检测高右心房压和高左心房压;高右心房压与高楔压及不良结局相关,无创估测血流动力学状态在左心室辅助装置患者临床管理中的获益尚需进一步评估。
研究设计与样本
- 前瞻性研究,纳入35例HVAD患者,同期行右心导管检查和多普勒超声心动图,以有创测压为参考标准。
诊断标准与关键数值
- 超声估测右心房压采用下腔静脉直径、肝静脉血流分析和三尖瓣E/e'比值,与有创右心房压相关r=0.839(P<0.001),检测高右心房压的曲线下面积0.94(P<0.001)。
- 超声估测左心房压采用E/A比值、二尖瓣E/e'比值和减速时间,与有创左心房压相关r=0.889(P<0.001),检测高左心房压的曲线下面积0.91(P<0.001)。
- 高估测右心房压与高左心房压相关,曲线下面积0.92(P<0.001)。
- 高估测右心房压与180天死亡或住院相关,比值比8.2(95%CI 1.1–21.0,P=0.04)。
- 根据估测左心房压和估测右心房压将患者分为4种血流动力学剖面,15例(43%)表现为最佳卸载剖面(估测右心房压正常且楔压正常),该剖面与其他剖面相比随访期不良心脏事件风险呈降低趋势(比值比0.2,95%CI 0.1–1.0,P=0.05)。
临床应用与阅片要点
- 可采用下腔静脉直径、肝静脉血流分析和三尖瓣E/e'比值估测HVAD患者右心房压,采用E/A比值、二尖瓣E/e'比值和减速时间估测左心房压。
- 估测右心房压升高时需关注合并左心房压升高及180天死亡或住院风险增加(比值比8.2,95%CI 1.1–21.0,P=0.04)。
- 作者认为无创估测血流动力学状态在左心室辅助装置患者临床管理中的获益尚需进一步评估。
局限性
- 原文结论指出无创估测血流动力学状态在左心室辅助装置患者临床管理中的获益尚需进一步评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this prospective study was to validate an echocardiographic protocol derived from 5 HeartWare left ventricular assist device (HVAD) patients for the noninvasive evaluation of right atrial pressure (RAP) and left atrial pressure (LAP) in HVAD patients.
BACKGROUND: Echocardiography is an invaluable tool to optimize medical treatment and pump settings and also for troubleshooting residual heart failure. Little is known about the echocardiographic evaluation of hemodynamic status in HVAD patients.
METHODS: Right heart catheterization and Doppler echocardiography were performed in 35 HVAD patients. Echocardiography-estimated RAP (eRAP) was assessed using inferior vena cava diameter, hepatic venous flow analysis, and tricuspid E/e' ratio. Echocardiography-estimated LAP was assessed using E/A ratio, mitral E/e' ratio, and deceleration time.
RESULTS: eRAP and estimated LAP significantly correlated with invasive RAP and LAP (respectively, r = 0.839, p < 0.001, and r = 0.889, p < 0.001) and accurately detected high RAP and high LAP (respectively, area under the curve 0.94, p < 0.001, and area under the curve 0.91, p < 0.001). High eRAP was associated with high LAP (area under the curve 0.92, p < 0.001) and correlated with death or hospitalization at 180 days (odds ratio: 8.2; 95% confidence interval: 1.1 to 21.0; p = 0.04). According to estimated LAP and eRAP, patients were categorized into 4 hemodynamic profiles. Fifteen patients (43%) showed the optimal unloading profile (normal eRAP and normal wedge pressure). This profile showed a trend toward a lower risk for adverse cardiac events at follow-up (odds ratio: 0.2; 95% confidence interval: 0.1 to 1.0; p = 0.05) compared with other hemodynamic profiles.
CONCLUSIONS: Doppler echocardiography accurately estimated hemodynamic status in HVAD patients. This algorithm reliably detected high RAP and LAP. Notably, high RAP was associated with high wedge pressure and adverse outcome. The benefit of noninvasive estimation of hemodynamic status in the clinical management of patients with left ventricular assist devices needs further evaluation.
引用
- Frea S, Centofanti P, Pidello S, et al. Noninvasive Assessment of Hemodynamic Status in HeartWare Left Ventricular Assist Device Patients: Validation of an Echocardiographic Approach. JACC Cardiovasc Imaging. 2018. PMID: 29550313. doi:10.1016/j.jcmg.2018.01.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。