文献速递心血管CT

基于CNR指数的低管电压CCTA辐射剂量降低研究

Radiation Dose Reduction at Low Tube Voltage CCTA Based on the CNR Index.
PubMed 文献 · Acad Radiol · 2018-03-26

本研究对比了相同CNR下120 kVp与100 kVp冠状动脉CT血管造影的辐射剂量和诊断准确性,纳入100例患者1311个冠状动脉节段。结果显示100 kVp方案平均剂量长度乘积较120 kVp降低48%(P < .01),以有创冠状动脉造影为标准,两种方案诊断准确性无显著差异(P = .87)。

要点

  • 100 kVp CCTA较120 kVp方案剂量长度乘积降低48%(P < .01)。
  • 两种管电压方案诊断冠状动脉狭窄≥50%的AUC均为0.94,差异无统计学意义(P = .87)。
  • 在相同CNR条件下,100 kVp方案可降低辐射剂量且不降低诊断准确性。

核心结论

  • 在相同CNR下,100 kVp CCTA方案较120 kVp方案可降低约50%的辐射剂量,且诊断准确性未见下降。

研究设计与样本

  • 研究纳入100例患者的1311个冠状动脉节段,对比120 kVp与100 kVp CCTA扫描;120 kVp扫描目标图像噪声水平设为25 HU,100 kVp扫描目标噪声水平设为30 HU以获得与120 kVp相同的CNR;以有创冠状动脉造影(ICA)为金标准,由介入冠状动脉造影专家评估ICA图像、放射科医生评估CCTA图像。

诊断标准与关键数值

  • 冠状动脉疾病定义为ICA和CCTA上管腔狭窄≥50%;120 kVp CCTA的AUC为0.94%(95%CI 0.91%-0.96%)、敏感度94.0%、特异度93.0%、阳性预测值82.3%、阴性预测值98.1%;100 kVp CCTA的AUC为0.94%(95%CI 0.92%-0.97%)、敏感度96.1%、特异度92.0%、阳性预测值85.2%、阴性预测值98.0%;两种方案诊断准确性无显著差异(P = .87)。

临床应用与阅片要点

  • 在相同CNR条件下,采用100 kVp CCTA方案可在不降低诊断准确性的前提下降低辐射剂量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: We compared the radiation dose and diagnostic accuracy on 120- and 100-kVp coronary computed tomography angiography (CCTA) scans whose contrast-to-noise ratio (CNR) was the same.

MATERIALS AND METHODS: We studied 1311 coronary artery segments from 100 patients. For 120-kVp scans, the targeted image level was set at 25 Hounsfield units (HU). For 100-kVp scans, the targeted noise level was set at 30 HU to obtain the same CNR as at 120 kVp. We compared the CNR and the radiation dose on scans acquired at 120 and 100 kVp. Invasive coronary angiography (ICA) images were evaluated by an interventional coronary angiography specialist, and CCTA images were evaluated by a radiologist. Coronary artery disease was defined as a luminal narrowing ≧50% for ICA and CCTA. With ICA considered the gold standard, the diagnostic accuracy (sensitivity, specificity, positive predictive value, and negative predictive value) was analyzed on both 120- and 100-kVp CCTA images. We also compared the diagnostic accuracy for area under the receiver operating characteristic curve of the ICA and CCTA performed at 120 and 100 kVp. Two blinded observers visually evaluated the septal branch.

RESULTS: The mean dose-length product was 48% lower at 100 kVp than at 120 kVp (P < .01). Under the 120-kVp CCTA protocol, the area under the curve, 95% confidence interval, sensitivity, specificity, positive predictive value, and negative predictive value were 0.94%, 0.91%-0.96%, 94.0%, 93.0%, 82.3%, and 98.1%, respectively; at 100 kVp these values were 0.94%, 0.92%-0.97%, 96.1%, 92.0%, 85.2%, and 98.0%, respectively. Area under the receiver operating characteristic curve analysis revealed no significant difference in diagnostic accuracy between the two protocols (P = .87).

CONCLUSIONS: At the same CNR, the 100-kVp CCTA protocol may help to reduce the radiation dose by approximately 50% compared to the 120-kVp protocol without degradation of diagnostic accuracy.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Masuda T, Funama Y, Nakaura T, et al. Radiation Dose Reduction at Low Tube Voltage CCTA Based on the CNR Index. Acad Radiol. 2018. PMID: 29599007. doi:10.1016/j.acra.2018.01.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。