文献速递心血管胸部CT

使用机器学习自动评估冠状动脉计算机断层血管造影的图像质量

Automated estimation of image quality for coronary computed tomographic angiography using machine learning.
PubMed 文献 · Eur Radiol · 2018-03-23

研究用75例冠状动脉CT血管造影训练机器学习方法,将噪声、对比度、配准不良评分和不可判读指数映射为图像质量评分,在50例验证集和172例新测试集上与5点Likert视觉评分比较。验证集AUC为0.96,测试集自动与视觉评估的Cohen kappa为0.67(p<0.01),自动评估可重复且与视觉分析结果相似。

要点

  • 自动评估与视觉图像质量评分的一致性Cohen kappa为0.67(p<0.01)。
  • 验证集自动评估图像质量的曲线下面积为0.96。
  • 视觉图像质量好至优的163例中155例自动评分>50%,一般6例中5例、差3例中2例自动评分>50%。

核心结论

  • 机器学习全自动评估冠状动脉CT血管造影图像质量具有可重复性,在操作者间变异范围内与视觉分析结果相似。

研究设计与样本

  • 研究使用75例冠状动脉CT血管造影研究训练机器学习方法,将噪声、对比度、配准不良评分和不可判读指数映射为基于手动参考数据的图像质量评分,在50例研究上验证,并在172例新研究上以5点Likert视觉图像质量评分为参照进行测试。

诊断标准与关键数值

  • 验证集自动评估图像质量的曲线下面积为0.96。
  • 172例测试集中自动与视觉图像质量评估的Cohen kappa为0.67(p<0.01)。
  • 视觉图像质量好至优163例中155例自动图像质量评分>50%。
  • 视觉图像质量一般6例中5例自动图像质量评分>50%。
  • 视觉图像质量差3例中2例自动图像质量评分>50%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Our goal was to evaluate the efficacy of a fully automated method for assessing the image quality (IQ) of coronary computed tomography angiography (CCTA).

METHODS: The machine learning method was trained using 75 CCTA studies by mapping features (noise, contrast, misregistration scores, and un-interpretability index) to an IQ score based on manual ground truth data. The automated method was validated on a set of 50 CCTA studies and subsequently tested on a new set of 172 CCTA studies against visual IQ scores on a 5-point Likert scale.

RESULTS: The area under the curve in the validation set was 0.96. In the 172 CCTA studies, our method yielded a Cohen's kappa statistic for the agreement between automated and visual IQ assessment of 0.67 (p < 0.01). In the group where good to excellent (n = 163), fair (n = 6), and poor visual IQ scores (n = 3) were graded, 155, 5, and 2 of the patients received an automated IQ score > 50 %, respectively.

CONCLUSION: Fully automated assessment of the IQ of CCTA data sets by machine learning was reproducible and provided similar results compared with visual analysis within the limits of inter-operator variability.

KEY POINTS: • The proposed method enables automated and reproducible image quality assessment. • Machine learning and visual assessments yielded comparable estimates of image quality. • Automated assessment potentially allows for more standardised image quality. • Image quality assessment enables standardization of clinical trial results across different datasets.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Nakanishi R, Sankaran S, Grady L, et al. Automated estimation of image quality for coronary computed tomographic angiography using machine learning. Eur Radiol. 2018. PMID: 29572635. doi:10.1007/s00330-018-5348-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。