文献速递心血管CT

70千伏冠状动脉CT血管成像中的线束硬化:使用先进后处理算法减少伪影

Beam-hardening in 70-kV Coronary CT angiography: Artifact reduction using an advanced post-processing algorithm.
PubMed 文献 · Eur J Radiol · 2018-02-16

该前瞻性研究纳入36例患者,行70kV冠状动脉CT血管成像,比较标准算法与迭代线束硬化校正算法(iBHC)重建图像。iBHC使左心室下壁等易发生线束硬化区域的心肌衰减显著增加,冠状动脉对比噪声比和信噪比提高,主观图像质量相当。

要点

  • iBHC算法使左心室下壁心肌衰减增加+13.9 HU(+18.6%),较其余心肌的+4.4 HU(+4.5%)更明显。
  • iBHC算法使左主干冠状动脉对比噪声比提高+20.7%、信噪比提高+17.3%,均P<0.001。
  • 两种重建图像的主观图像质量相当(P=0.217),iBHC未降低主观评分。

核心结论

  • iBHC后处理算法可显著减少70kV冠状动脉CT血管成像中的线束硬化,同时提供改善的客观图像质量和相当的主观图像质量。

研究设计与样本

  • 前瞻性研究,经IRB批准,纳入36例患者(17例男性,平均年龄57.3±14.5岁),使用第三代双源CT行70kV冠状动脉CT血管成像,分别用标准算法(Bv36)联合或不联合iBHC技术重建图像。

关键影像表现/征象

  • iBHC算法总体上增加所有感兴趣区的心肌衰减(P<0.566),但在左心室下壁等易发生线束硬化的区域增加更为显著(+13.9 HU,+18.6%,P<0.001),其余心肌增加+4.4 HU(+4.5%,P<0.003)。
  • 图像噪声在两种重建图像间无显著差异(P=0.092)。

诊断标准与关键数值

  • 使用iBHC算法后,左主干冠状动脉的对比噪声比提高+20.7%、信噪比提高+17.3%(均P<0.001)。
  • 主观图像质量在两种图像序列间相当(P=0.217)。

临床应用与阅片要点

  • 在70kV冠状动脉CT血管成像中,iBHC后处理算法可减少左心室下壁等线束硬化易发区域的心肌衰减伪影,提高左主干冠状动脉的客观图像质量指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the effect of an iterative beam-hardening correction algorithm (iBHC) on artifact reduction and image quality in coronary CT angiography (cCTA) with low tube voltage.

MATERIAL AND METHODS: Thirty-six patients (17 male, mean age, 57.3 ± 14.5 years) were prospectively enrolled in this IRB-approved study and underwent 70-kV cCTA using a third-generation dual-source CT scanner. Images were reconstructed using a standard algorithm (Bv36) both with and without the iBHC technique. Several region-of-interest (ROI) measurements were performed in the inferior wall of the left ventricle (LV), an area prone to beam-hardening, as well as other myocardial regions. Coronary contrast-to-noise (CNR) and signal-to-noise ratios (SNR) were calculated. Two radiologists assessed subjective image quality.

RESULTS: The iBHC algorithm generally increased myocardial attenuation in all ROIs (P < 0.566); however, the increase was significantly more distinct in beam-hardening prone areas such as the inferior LV (increase, +13.9 HU, +18.6%, P < 0.001), compared to the remaining myocardium (increase, +4.4 HU, +4.5%, P < 0.003). While no significant difference was found for image noise (P < 0.092), greater CNR and SNR values for the left main coronary artery (increase, +20.7% and +17.3%, respectively) were found using the iBHC algorithm (both with P < 0.001). Subjective image quality was comparable between both image series (P = 0.217).

CONCLUSION: The iBHC post-processing algorithm leads to significantly reduced beam-hardening while providing improved objective and equivalent subjective image quality in 70-kV cCTA.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Albrecht MH, Bickford MW, Schoepf UJ, et al. Beam-hardening in 70-kV Coronary CT angiography: Artifact reduction using an advanced post-processing algorithm. Eur J Radiol. 2018. PMID: 29571783. doi:10.1016/j.ejrad.2018.02.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。