文献速递心血管MR

7T自门控晚期钆增强成像用于再灌注急性心肌梗死大鼠

Self-Gated Late Gadolinium Enhancement at 7T to Image Rats with Reperfused Acute Myocardial Infarction.
PubMed 文献 · Korean J Radiol · 2018-02-22

在7T下对10只心肌梗死/再灌注大鼠行自门控(SG)或心电呼吸双门控(ECG-RESP)晚期钆增强(LGE)成像,比较图像干扰与采集时间(TA),并优化翻转角(FA)与重复次数(NR)。SG-LGE成功扫描10只(100%),ECG-RESP仅4只(40%);推荐FA 20°-30°、NR 80,SG-LGE可作为ECG-RESP的替代方法。

要点

  • SG-LGE在10只大鼠中全部扫描成功(100%),ECG-RESP仅4只成功(40%)。
  • SG-LGE的TA随NR变化:NR 40、80、150、300对应TA 41、82、154、307秒;ECG-RESP平均TA 220秒。
  • 推荐SG-LGE采用FA 20°-30°、NR 80,可获得较优CNR与图像质量评分。

核心结论

  • 自门控技术无需规则心电或呼吸门控即可改善LGE图像质量,SG-LGE可作为ECG-RESP门控的替代方法。

研究设计与样本

  • 研究论文;10只心肌梗死/再灌注大鼠,7T行CMR,比较SG-LGE与ECG-RESP双门控法的图像干扰和TA,并优化SG-LGE的FA(10°-80°)与NR(40、80、150、300)。

诊断标准与关键数值

  • SG-LGE不同FA(10°、15°、20°、25°、30°、35°、40°)的CNR分别为42.5±5.5、43.5±7.5、54±9、59.5±8.5、56±13、54±8、41±9,图像质量评分分别为1.85±0.75、2.20±0.83、2.85±0.37、3.85±0.52、2.8±0.51、2.45±0.76、1.95±0.60;推荐FA 20°-30°、NR 80。

临床应用与阅片要点

  • 作者推荐SG-LGE采用FA 20°-30°、NR 80;SG-LGE可作为ECG-RESP门控的替代方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: A failed electrocardiography (ECG)-trigger often leads to a long acquisition time (TA) and deterioration in image quality. The purpose of this study was to evaluate and optimize the technique of self-gated (SG) cardiovascular magnetic resonance (CMR) for cardiac late gadolinium enhancement (LGE) imaging of rats with myocardial infarction/reperfusion.

MATERIALS AND METHODS: Cardiovascular magnetic resonance images of 10 rats were obtained using SG-LGE or ECG with respiration double-gating (ECG-RESP-gating) method at 7T to compare differences in image interference and TA between the two methods. A variety of flip angles (FA: 10°-80°) and the number of repetitions (NR: 40, 80, 150, and 300) were investigated to determine optimal scan parameters of SG-LGE technique based on image quality score and contrast-to-noise ratio (CNR).

RESULTS: Self-gated late gadolinium enhancement allowed successful scan in 10 (100%) rats. However, only 4 (40%) rats were successfully scanned with the ECG-RESP-gating method. TAs with SG-LGE varied depending on NR used (TA: 41, 82, 154, and 307 seconds, corresponding to NR of 40, 80, 150, and 300, respectively). For the ECG-RESP-gating method, the average TA was 220 seconds. For SG-LGE images, CNR (42.5 ± 5.5, 43.5 ± 7.5, 54 ± 9, 59.5 ± 8.5, 56 ± 13, 54 ± 8, and 41 ± 9) and image quality score (1.85 ± 0.75, 2.20 ± 0.83, 2.85 ± 0.37, 3.85 ± 0.52, 2.8 ± 0.51, 2.45 ± 0.76, and 1.95 ± 0.60) were achieved with different FAs (10°, 15°, 20°, 25°, 30°, 35°, and 40°, respectively). Optimal FAs of 20°-30° and NR of 80 were recommended.

CONCLUSION: Self-gated technique can improve image quality of LGE without irregular ECG or respiration gating. Therefore, SG-LGE can be used an alternative method of ECG-RESP-gating.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Wang L, Chen Y, Zhang B, et al. Self-Gated Late Gadolinium Enhancement at 7T to Image Rats with Reperfused Acute Myocardial Infarction. Korean J Radiol. 2018. PMID: 29520182. doi:10.3348/kjr.2018.19.2.247

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。