文献速递心血管外周血管技术与安全USMR

腺苷全身效应评估:脾动脉彩色多普勒超声的可行性及其在冠状动脉介入中的潜在临床价值

Assessment of Systemic Adenosine Effect Using Color Doppler Ultrasound of the Splenic Artery-Feasibility and Potential Clinical Utility for Coronary Interventions.
PubMed 文献 · Ultrasound Med Biol · 2018-03-01

在26例患者腺苷输注期间行脾动脉彩色多普勒,测量输注前及输注2分钟时峰值流速,并与磁共振灌注成像定性比较。24例脾动脉峰值流速从62.3±18.1降至40.4±15.7 cm/s(p<0.001),对应磁共振灌注受限;2例流速不变者无灌注受限。首次在人体证实腺苷下评估脾动脉流速变化的可行性,需进一步研究其能否可靠排除冠状动脉导管术中血流储备分数测量时腺苷效应不足。

要点

  • 腺苷输注2分钟时脾动脉峰值流速较输注前下降,与磁共振灌注受限定性对应。
  • 脾动脉流速不变的两例患者磁共振未见灌注受限,提示可能反映腺苷无反应。
  • 该應用尚需进一步研究验证其能否可靠排除血流储备分数测量时腺苷效应不足。

核心结论

  • 首次在人体证实腺苷输注下用脾动脉彩色多普勒评估全身腺苷效应的可行性,脾动脉峰值流速下降与磁共振灌注受限定性对应;该新应用能否作为可靠工具排除冠状动脉导管术中血流储备分数测量时腺苷效应不足,尚需进一步研究。

研究设计与样本

  • 在26例患者腺苷输注期间行脾动脉彩色多普勒,于输注前及输注2分钟测量脾动脉峰值流速,并与磁共振灌注成像定性比较。

关键影像表现/征象

  • 腺苷输注2分钟时脾动脉峰值流速较输注前下降,对应磁共振灌注受限。
  • 脾动脉流速保持不变的2例患者磁共振未见灌注受限。

诊断标准与关键数值

  • 24例患者脾动脉峰值流速从输注前62.3±18.1 cm/s降至输注2分钟40.4±15.7 cm/s(p<0.001),对应磁共振灌注受限。
  • 2例脾动脉流速不变者磁共振未见灌注受限。

临床应用与阅片要点

  • 作者指出需进一步研究该新应用能否作为可靠工具,排除冠状动脉导管术中血流储备分数测量时腺苷效应不足。

局限性

  • 原文指出需进一步研究该新应用能否作为可靠工具排除冠状动脉导管术中血流储备分数测量时腺苷效应不足。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Adenosine induces coronary vasodilation and simultaneously reduces splanchnic perfusion. This effect can be absent in adenosine non-responders. Imaging of splanchnic arteries under adenosine assessing this effect has not been performed in humans previously. In 26 patients, splenic artery color Doppler was performed during an infusion of adenosine. Peak velocity in the splenic artery was measured before the infusion and at 2 min. Results were compared qualitatively with perfusion imaging in magnetic resonance. A total of 24 patients showed a drop of splenic artery peak velocity from 62.3 ± 18.1 to 40.4 ± 15.7 cm/s (p <0.001), which corresponded to perfusion restriction in magnetic resonance. Two patients with constant splenic artery velocity did not show perfusion restriction. We showed feasibility of assessing changes in splenic artery velocity under adenosine for the first time in humans. Further studies are needed to investigate whether this novel application is a robust tool to rule out inadequate adenosine effect during measurement of fractional flow reserve in coronary catheterization.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Klein-Wiele O, Sherifa W, Garmer M, et al. Assessment of Systemic Adenosine Effect Using Color Doppler Ultrasound of the Splenic Artery-Feasibility and Potential Clinical Utility for Coronary Interventions. Ultrasound Med Biol. 2018. PMID: 29503018. doi:10.1016/j.ultrasmedbio.2018.01.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。