儿科或新生儿重症监护病房中儿科放射科医师与儿科重症监护医师对X线片解读的差异
这项多机构前瞻性研究在两家儿科重症监护病房和三家新生儿重症监护病房中比较了儿科重症监护医师与儿科放射科医师对960份胸腹部X线片解读的差异,总差异率为34.7%,其中不可操作差异占26.8%,可操作差异占7.9%;可操作差异最常见于导管和引流管位置以及肺实质阴影的识别与解读。
要点
- 总差异率34.7%,其中可操作差异仅7.9%,不可操作差异占26.8%。
- 可操作差异最常见于导管和引流管位置,其次为肺实质阴影识别与解读。
- 气漏占全部差异的1%、可操作差异的11%;新生儿监护病房正常与异常肠气分布鉴别也较常见。
核心结论
- 总差异率虽高,但大多数差异不可操作;可操作差异主要源于导管和引流管位置,应作为重点教育领域。
研究设计与样本
- 经机构审查委员会批准的多机构前瞻性研究,纳入两家儿科重症监护病房和三家新生儿重症监护病房的三名儿科放射科医师和儿科重症监护医师,将胸部和腹部X线片的解读记录于在线表格并进行比较。
关键影像表现/征象
- 可操作差异最常见于导管或引流管位置以及肺实质阴影的识别与解读。
- 儿科重症监护病房气漏的识别和新生儿重症监护病房正常与异常肠气分布的鉴别在可操作差异频率中紧随其后。
- 不可操作差异包括儿科重症监护病房的心后肺不张和新生儿重症监护病房对新生儿肺疾病的错误定性。
诊断标准与关键数值
- 差异分为「漏诊」、「误判」或「过度诊断」,并依据美国放射学会可操作报告工作组可操作发现列表的外推分为「可操作」或「不可操作」。
- 960份X线片解读中,总差异率34.7%,不可操作差异率26.8%,可操作差异率7.9%。
- 气漏占全部差异的1%,占可操作差异的11%。
临床应用与阅片要点
- 作者认为导管和引流管位置应作为重点教育领域。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: In pediatric intensive care units (PICUs) and neonatal intensive care units (NICUs), patient management decisions are sometimes based on preliminary interpretations of radiographs by pediatric intensivists (PIs) before a formal interpretation by a pediatric radiologist (PR).
OBJECTIVE: To quantify and classify discrepancies in radiographic interpretation between PRs and PIs in the PICU and NICU.
MATERIALS AND METHODS: This institutional review board-approved multi-institutional prospective study included three PRs and PIs at two PICUs and three NICUs. Interpretations of chest and abdominal radiographs by PIs and PRs were recorded on online forms and compared. Discrepancies in interpretations were classified as "miss," "misinterpretation," or "overcall." The discrepancies were also categorized as "actionable" or "nonactionable" based on extrapolation of the ACR actionable reporting work group's list of actionable findings.
RESULTS: In 960 radiographic interpretations, the total, nonactionable, and actionable discrepancy rates between PRs and PIs were 34.7%, 26.8%, and 7.9%, respectively. The most common actionable discrepancies were line or tube positions and identification and interpretation of parenchymal opacities in the lungs. Identification of air leaks in the PICU and differentiation of normal from abnormal bowel gas patterns in the NICU followed in frequency. Air leaks accounted for 1% of total discrepancies and 11% of actionable discrepancies. Most discrepancies were nonactionable and included retrocardiac atelectasis and mischaracterization of neonatal lung disease in the PICU and NICU, respectively.
CONCLUSION: Although the total discrepancy rate was high, most discrepancies were nonactionable. Actionable discrepancies were predominantly due to line and tube position, which should be an area of focused education.
引用
- Fink AZ, Levin TL, Blumfield E, et al. Discrepancies in Radiograph Interpretation Between Pediatric Radiologists and Pediatric Intensivists in the Pediatric or Neonatal Intensive Care Unit. J Am Coll Radiol. 2018. PMID: 29501502. doi:10.1016/j.jacr.2017.12.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。