基于梯度回波的3D亚毫秒回波时间肺部MR成像:临床与临床前MR扫描仪的初步可用性研究
本研究初步探讨亚毫秒回波时间同步去相位与激发(CODE)序列在临床与临床前MR扫描仪上行肺部MRI的技术可行性,在体模、健康志愿者、兔和啮齿类动物中评估信噪比、图像质量及支气管和结节可见性。CODE序列信噪比高于原始三维超短回波时间序列,人图像质量优于常规序列,兔和啮齿类动物支气管可追溯至第五级支气管。
要点
- CODE序列回波时间0.14~0.18 ms,在3T临床及9.4T临床前扫描仪上技术可行。
- 体模中信噪比CODE高于原始三维超短回波时间序列(106.71±4.32 vs 91.66±3.54,p<0.001)。
- 兔和啮齿类动物CODE图像支气管可追溯至第五级支气管。
核心结论
- 亚毫秒回波时间肺部MRI使用CODE序列在多种MR扫描仪上技术可行,CODE可作为临床和临床前扫描仪肺部MRI的实用替代方案,无需基于自由感应衰减的超短回波时间序列的挑战。
研究设计与样本
- 初步技术可行性研究,使用CODE成像(回波时间0.14~0.18 ms),在3T下对美国放射学会体模成像、1.5T和3T下对7名健康志愿者成像、3T下对10只兔成像、9.4T下对2只啮齿类动物成像;体模中比较信噪比,人MRI图像质量采用5分制视觉评估比较CODE与常规肺部MRI序列,动物研究中评估支气管、亚厘米结节和MR空气支气管征的可见性。
关键影像表现/征象
- 兔和啮齿类动物CODE图像中支气管可追溯至第五级支气管。
- 兔中95.2%的转移性结节(直径1.5±0.4 mm)可见。
- 兔中93.8%的MR空气支气管征(直径0.9±0.2 mm)可见。
诊断标准与关键数值
- 体模中信噪比CODE为106.71±4.32,原始三维超短回波时间序列为91.66±3.54,p<0.001。
- 人MRI图像质量CODE优于常规MRI序列(p≤0.002)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To preliminarily investigate a technical feasibility of a submillisecond echo time concurrent-dephasing-and-excitation (CODE) sequence for pulmonary MRI on clinical and preclinical MR scanners Methods: CODE imaging (echo time, 0.14 ~ 0.18 ms) was performed with American College of Radiology phantom at 3 T, 7 healthy volunteers at 1.5 and 3 T, 10 rabbits at 3 T, and 2 rodents at 9.4 T. Signal-to-noise ratio was compared in phantom. Image quality of human MRI was visually assessed on a 5-point scale for comparison between CODE and conventional lung MRI sequences. Visibility of bronchi, subcentimeter nodules, and MR air-bronchogram were assessed in animal studies.
RESULTS: In phantom study, signal-to-noise ratio was higher with CODE than with original three-dimensional ultrashort-echo time sequence (106.71 ± 4.32 vs 91.66 ± 3.54; p < 0.001). Image quality of human MRI was better with CODE than with conventional MRI sequences (p ≤ 0.002). Bronchi remained traceable up to the fifth bronchial generation in CODE images in rabbits and rodents. 95.2% of metastatic nodules (diameter, 1.5 ± 0.4 mm) and 93.8% of MR air-bronchogram (diameter, 0.9 ± 0.2 mm) in rabbits.
CONCLUSION: Submillisecond echo time pulmonary MRI was technically feasible by using CODE on various MR scanners. Advances in knowledge: CODE can be a practical alternative for lung MRI on both clinical and pre-clinical scanners, without challenges of free-induction-decay-based ultrashort-echo time sequences.
引用
- Yoon SH, Lee C, Park J, et al. Gradient-echo-based 3D submillisecond echo time pulmonary MR imaging: a preliminary usability study on clinical and preclinical MR scanners. Br J Radiol. 2018. PMID: 29569463. doi:10.1259/bjr.20170796
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。