文献速递胸部CT

改进CT对肺腺癌浸润成分的预测:亚实性结节软件分割中血管去除算法的价值

Improving the prediction of lung adenocarcinoma invasive component on CT: Value of a vessel removal algorithm during software segmentation of subsolid nodules.
PubMed 文献 · Eur J Radiol · 2018-01-31

本研究纳入2014年1月至2015年6月间73个病理浸润成分≤10 mm的亚实性结节,由2名放射科医师在血管去除前后进行半自动分割,比较软件实性成分测量与病理浸润成分直径。68个结节成功分割,血管去除后软件与病理测量相关性(r=0.49-0.54)优于去除前(r=0.27-0.41),三维最长径在血管去除后与病理差异无统计学意义(p=0.53-0.83),提示血管去除算法可改善浸润成分预测。

要点

  • 血管去除后软件实性成分与病理浸润成分相关性(r=0.49-0.54)优于去除前(r=0.27-0.41)。
  • 血管去除后三维最长径与病理浸润成分平均差异最小(-0.26至0.10 mm),差异无统计学意义(p=0.53-0.83)。
  • 血管去除前软件实性成分与病理浸润成分的平均测量差异显著大于去除后(所有测量指标)。

核心结论

  • 在亚实性结节的软件分割中加入血管去除算法,可改善肺腺癌浸润成分的预测。

研究设计与样本

  • 研究纳入2014年1月至2015年6月间73个病理浸润成分≤10 mm的亚实性结节,最终68个成功分割并分析;由2名放射科医师进行半自动分割,分别在血管去除前后获取实性成分的三维最长径、轴位最长径和有效直径,以病理浸润成分直径为参考标准,采用配对t检验和Pearson相关检验比较。

诊断标准与关键数值

  • 病理浸润成分平均最大直径4.6 mm(范围0-10 mm);血管去除后软件与病理测量相关性r=0.49-0.54,去除前r=0.27-0.41(p<0.01);血管去除后三维最长径与病理平均差异-0.26至0.10 mm,差异无统计学意义(p=0.53-0.83)。

临床应用与阅片要点

  • 在亚实性结节软件分割中应用血管去除算法,可提高CT实性成分测量与病理浸润成分的一致性。
  • 血管去除后三维最长径与病理浸润成分差异最小且无统计学意义,可作为软件测量的优先指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the value of a vessel removal algorithm in segmentation of subsolid nodules by comparing the software solid component measurement on CT, before and after vessel removal, with the measurement of the invasive component on pathology in lung adenocarcinomas manifesting as subsolid nodules.

MATERIALS AND METHODS: Between January 2014 and June 2015, 73 subsolid nodules with an invasive component of ≤10 mm on pathology were selected for analyses. For each nodule, semi-automated segmentation was performed by 2 radiologists and 3-dimensional (D) longest, axial longest and effective diameters of solid component were obtained from software, before and after using a vessel removal tool. These measurements were compared with the invasive component diameter on pathology using the paired t-test and Pearson's correlation test.

RESULTS: Sixty-eight successfully segmented subsolid nodules were included. The mean maximal diameter of the invasive component on pathology was 4.6 mm (range, 0-10 mm). The correlation between software and pathology measurements was significant (p < 0.01) and the correlation after vessel removal (r = 0.49-0.54) was better than before vessel removal (r = 0.27-0.41). The mean measurement difference between solid component on CT and invasive tumor on pathology was significantly larger before vessel removal than after vessel removal in all measurements. The smallest mean measurement difference was obtained with 3D longest diameter of solid component after vessel removal in both readers (-0.26 mm to 0.10 mm), with no significant difference from pathology (p = 0.53-0.83).

CONCLUSION: By adding a vessel removal algorithm in software segmentation of subsolid nodules, the prediction of invasive component in lung adenocarcinomas can be improved.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Garzelli L, Goo JM, Ahn SY, et al. Improving the prediction of lung adenocarcinoma invasive component on CT: Value of a vessel removal algorithm during software segmentation of subsolid nodules. Eur J Radiol. 2018. PMID: 29496080. doi:10.1016/j.ejrad.2018.01.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。