本研究纳入43例直径小于3 cm的实性肺癌患者(腺癌25例、鳞状细胞癌18例),评估CT密度直方图参数(峰度、偏度)与FDG-PET/CT的SUVmax(有无呼吸门控)区分实性肺腺癌与鳞状细胞癌的能力及相关性。结果显示峰度与SUVmax(有无呼吸门控)在两组间差异显著,联合参数AUC最高(0.949),峰度与呼吸门控SUVmax相关性最强(ρ=0.618)。

要点

  • 峰度区分实性肺腺癌与鳞状细胞癌的AUC为0.760,偏度为0.593。
  • 呼吸门控SUVmax的AUC为0.931,高于无呼吸门控SUVmax的0.900。
  • 峰度联合呼吸门控SUVmax与偏度的组合参数AUC最高,为0.949。

核心结论

  • 定量CT直方图值与SUV评估可区分实性肺腺癌与鳞状细胞癌,峰度与SUVmax值强相关,加入呼吸门控并进一步联合参数可改善结果。

研究设计与样本

  • 研究纳入43例连续实性肺癌患者(直径小于3 cm;腺癌25例,鳞状细胞癌18例),均行平扫胸部CT与FDG-PET/CT;从胸部CT图像创建靶病灶密度直方图并计算峰度与偏度,计算有无呼吸门控的SUVmax;采用Mann-Whitney检验比较组间参数,ROC曲线分析评估诊断效能。

诊断标准与关键数值

  • 峰度AUC为0.760,偏度AUC为0.593,无呼吸门控SUVmax的AUC为0.900,呼吸门控SUVmax的AUC为0.931,联合参数AUC为0.949;峰度组间比较P<0.004,有无呼吸门控SUVmax组间比较均P<0.0001。

临床应用与阅片要点

  • 作者结论认为定量CT直方图值与SUV评估可区分实性肺腺癌与鳞状细胞癌,加入呼吸门控并进一步联合参数可改善结果。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the ability of parameters derived from computed tomography (CT) histograms and the maximum standardized uptake value (SUVmax) of 18F-fludeoxyglucose-positron emission tomography/CT (FDG-PET/CT) images to distinguish solid lung adenocarcinomas from squamous cell carcinomas and to determine if these parameters are correlated.

METHODS: This study comprised 43 consecutive patients with solid lung cancer (<3 cm in diameter), who underwent both plain chest CT and FDG-PET/CT (adenocarcinoma, n = 25; squamous cell carcinoma, n = 18). Density histograms of targeted lung cancers were created from chest CT images, and kurtosis and skewness were calculated. On FDG-PET/CT, the SUVmax without/with respiratory gating (RG) were calculated for each lesion. The values for the 4 parameters determined for patients in each diagnostic group were compared by the Mann-Whitney test. The diagnostic characteristics of the parameters were assessed by receiver operating characteristic (ROC) curve analysis. Differences between these parameters were assessed by the chi-square test. SUVmax with RG, kurtosis, and skewness were combined for binary logistic regression analysis, and the differences between the combined parameters and SUVmax with RG were also assessed. Spearman rank correlation analysis was used to determine the correlations for kurtosis or for skewness with SUVmax without/with RG.

RESULTS: The differences in kurtosis and SUVmax without/with RG between the diagnostic groups were significant (kurtosis, P < 0.004; SUVmax without/with RG both P < 0.0001). ROC curve analysis indicated that each parameter (kurtosis value, skewness value, SUVmax, without/with RG) provided low-high ability to differentiate between 2 groups (area under the curve [AUC]: 0.760, 0.593, 0.900, 0.931, respectively). The ROC of the combined parameters provided the highest ability (AUC: 0.949). Both kurtosis and skewness were significantly correlated with SUVmax without/with RG. Kurtosis and SUVmax with RG were most strongly correlated (ρ = 0.618).

CONCLUSION: Quantitative CT histogram values and SUV assessment can differentiate solid lung adenocarcinomas from squamous cell carcinomas. Kurtosis and SUVmax values were strongly correlated. The addition of RG and further combination of the parameters improved the results.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Tsubakimoto M, Yamashiro T, Tamashiro Y, et al. Quantitative CT density histogram values and standardized uptake values of FDG-PET/CT with respiratory gating can distinguish solid adenocarcinomas from squamous cell carcinomas of the lung. Eur J Radiol. 2018. PMID: 29496067. doi:10.1016/j.ejrad.2018.01.021