文献速递胸部CT

亚实性结节亚分类的定性CT标准:提高观察者间一致性并与腺癌谱系病理侵袭性相关

Qualitative CT Criterion for Subsolid Nodule Subclassification: Improving Interobserver Agreement and Pathologic Correlation in the Adenocarcinoma Spectrum.
PubMed 文献 · Acad Radiol · 2018-03-09

研究纳入41个亚实性结节,由6名观察者分别按传统与新型定性CT分类系统独立判读,间隔至少8周。新型分类将亚实性结节分为纯磨玻璃结节、异质性磨玻璃结节和部分实性结节,观察者间一致性良好(κ=0.707),且与腺癌谱系病理侵袭性的相关性(相关系数0.622–0.732)优于传统分类(0.458–0.644)。作者结论认为新型分类系统一致性良好且与病理侵袭性相关性更佳,但尚需进一步研究确认观察者间一致性的结果。

要点

  • 新型定性CT分类将亚实性结节分为纯磨玻璃结节、异质性磨玻璃结节和部分实性结节。
  • 新型分类观察者间一致性κ=0.707,传统分类κ=0.702,两者均属良好。
  • 新型分类与病理侵袭性相关系数0.622–0.732,优于传统分类的0.458–0.644。

核心结论

  • 新型亚实性结节定性CT分类系统的观察者间一致性良好,且与传统分类相比与腺癌谱系病理侵袭性的相关性更强;尚需进一步研究确认观察者间一致性的结果。

研究设计与样本

  • 研究纳入41个亚实性结节,由6名观察者独立判读CT图像,分别按传统和新型两种分类系统进行评估,两次判读间隔至少8周;采用κ系数检验评估可靠性,采用Spearman相关系数分析肺腺癌谱系与亚实性结节分类的相关性。

关键影像表现/征象

  • 新型分类将亚实性结节分为纯磨玻璃结节、异质性磨玻璃结节和部分实性结节三类。
  • 传统分类与新型分类的观察者间一致性κ分别为0.702(范围0.42–0.89)和0.707(范围0.58–0.88)。
  • 传统分类与新型分类的观察者内一致性κ分别为0.92和0.88。

诊断标准与关键数值

  • 新型亚实性结节分类与病理侵袭性的相关系数范围为0.622–0.732,传统分类为0.458–0.644。
  • 观察者间一致性κ:传统分类0.702(范围0.42–0.89),新型分类0.707(范围0.58–0.88)。
  • 观察者内一致性κ:传统分类0.92,新型分类0.88。

临床应用与阅片要点

  • 作者结论认为新型亚实性结节分类系统观察者间一致性良好,且与病理侵袭性相关性优于传统分类。
  • 作者指出尚需进一步研究确认观察者间一致性的结果。

局限性

  • 作者指出尚需进一步研究确认观察者间一致性的结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: The main aim of this study was to evaluate the clinical validity and correlation with pathologic invasiveness in the pulmonary adenocarcinoma spectrum based on the novel qualitative computed tomography criterion for subsolid nodule (SSN) classification, which classified SSN into pure ground-glass nodule, heterogeneous ground-glass nodule, and part-solid nodule. In addition, we compared the performance of the conventional and novel classifications.

MATERIALS AND METHODS: The computed tomography images of 41 SSN nodules were interpreted by six observers independently, and the SSN characteristics were classified according to both the conventional and the novel classification systems. Each observer assessed 41 nodules in two different classifications separated by a minimum of 8 weeks. The kappa (κ) coefficient test was used to determine the reliability. The correlation between pulmonary adenocarcinoma spectrum and the SSN classification was analyzed with Spearman correlation coefficients.

RESULTS: Interobserver agreement (κ) was 0.702 (range 0.42-0.89) and 0.707 (range 0.58-0.88) for the conventional and the novel classifications for SSN, respectively, and intraobserver agreement (κ) was 0.92 and 0.88 for the conventional and the novel classifications for SSN, respectively. The novel SSN classification (correlation coefficient range 0.622-0.732) is more strongly correlated with the pathologic invasiveness degree of lesions in adenocarcinoma spectrum than the conventional SSN classification (correlation coefficient range 0.458-0.644).

CONCLUSIONS: The agreement between observers on the novel SSN classification system was good and had better correlation with pathologic invasiveness than the conventional SSN classification. Further studies are needed to confirm these results on interobserver agreement.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Chen PA, Huang EP, Shih LY, et al. Qualitative CT Criterion for Subsolid Nodule Subclassification: Improving Interobserver Agreement and Pathologic Correlation in the Adenocarcinoma Spectrum. Acad Radiol. 2018. PMID: 29530486. doi:10.1016/j.acra.2018.01.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。