文献速递胸部儿科影像MR

非增强磁共振成像可检测早期囊性纤维化肺病的马赛克信号强度

Non-contrast enhanced magnetic resonance imaging detects mosaic signal intensity in early cystic fibrosis lung disease.
PubMed 文献 · Eur J Radiol · 2018-02-21

研究纳入50例婴幼儿及学龄前囊性纤维化患儿,比较非增强HASTE形态学MRI马赛克信号评分与增强4D灌注MRI灌注评分的一致性。马赛克评分与灌注评分方法间一致性中等(κ=0.58-0.59),阅片者间一致性较高(κ=0.71),马赛克评分轻度低估灌注异常(偏倚0.46-0.48)。提示非增强MRI可可靠检测马赛克信号强度,反映肺血容量分布,可在有对比剂禁忌时作为灌注MRI的替代。

要点

  • 非增强HASTE序列可评估婴幼儿囊性纤维化肺病的马赛克信号强度。
  • 马赛克评分与灌注评分方法间一致性中等,κ=0.58(R1)和0.59(R2)。
  • 马赛克评分轻度低估灌注异常,偏倚0.48(R1)和0.46(R2)。

核心结论

  • 非增强MRI可可靠检测婴幼儿及学龄前囊性纤维化患儿的马赛克信号强度,反映肺血容量分布,可在有对比剂禁忌或替代技术不可用时作为灌注MRI的替代。

研究设计与样本

  • 50例婴幼儿及学龄前囊性纤维化患者(平均年龄3.5±1.4岁,范围0-6岁)常规接受形态学T2加权涡轮自旋回波半傅里叶采集(HASTE)序列和增强4D灌注MRI(梯度回波序列并行采集与回波共享,TWIST);两名阅片者对患者年龄和临床数据盲法独立评分,灌注MRI评分作为参考标准。

关键影像表现/征象

  • HASTE序列上肺实质信号异常按肺叶评分:0分为正常,1分为受累肺叶<50%,2分为受累肺叶≥50%。
  • Bland-Altman分析显示马赛克评分有轻度低估灌注异常的倾向,评分偏倚R1为0.48、R2为0.46。

诊断标准与关键数值

  • HASTE序列肺实质信号异常评分:0分正常,1分受累肺叶<50%,2分受累肺叶≥50%。
  • 灌注MRI按先前建立的MRI评分标准评分,并作为参考标准。

临床应用与阅片要点

  • 作者认为,非增强MRI可可靠检测马赛克信号强度,反映肺血容量分布,可在有对比剂禁忌或替代技术不可用时作为灌注MRI的替代。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine if morphological non-contrast enhanced magnetic resonance imaging (MRI) of the lung is sensitive to detect mosaic signal intensity in infants and preschool children with cystic fibrosis (CF).

MATERIALS AND METHODS: 50 infant and preschool CF patients (mean age 3.5 ± 1.4y, range 0-6y) routinely underwent morphological (T2-weighted turbo-spin echo sequence with half-Fourier acquisition, HASTE) and contrast-enhanced 4D perfusion MRI (gradient echo sequence with parallel imaging and echo sharing, TWIST). MRI studies were independently scored by two readers blinded for patient age and clinical data (experienced Reader 1 = R1, inexperienced Reader 2 = R2). The extent of lung parenchyma signal abnormalities on HASTE was rated for each lobe from 0 (normal), 1 (<50% of lobe affected) to 2 (≥50% of lobe affected). Perfusion MRI was rated according to the previously established MRI score, and served as the standard of reference.

RESULTS: Inter-method agreement between MRI mosaic score and perfusion score was moderate with κ = 0.58 (confidence interval 0.45-0.71) for R1, and with κ = 0.59 (0.46-0.72) for R2. Bland-Altman analysis revealed a slight tendency of the mosaic score to underestimate perfusion abnormalities with a score bias of 0.48 for R1 and 0.46 for R2. Inter-reader agreement for mosaic score was substantial with κ = 0.71 (0.62-0.79), and a low bias of 0.02.

CONCLUSIONS: This study demonstrates that non-contrast enhanced MRI reliably detects mosaic signal intensity in infants and preschool children with CF, reflecting pulmonary blood volume distribution. It may thus be used as a surrogate for perfusion MRI if contrast material is contra-indicated or alternative techniques are not available.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Leutz-Schmidt P, Stahl M, Sommerburg O, et al. Non-contrast enhanced magnetic resonance imaging detects mosaic signal intensity in early cystic fibrosis lung disease. Eur J Radiol. 2018. PMID: 29571794. doi:10.1016/j.ejrad.2018.02.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。