文献速递胸部CT

血管抑制胸部CT用于实性肺结节半自动容积测量

Vessel suppressed chest Computed Tomography for semi-automated volumetric measurements of solid pulmonary nodules.
PubMed 文献 · Eur J Radiol · 2018-02-15

研究对93例标准胸部CT用专用软件行血管抑制处理,比较65个实性结节在标准CT与血管抑制CT上的半自动容积测量,由两名阅片者重复测量。血管抑制CT与参考值一致性极高(Lin CCC 0.990/0.985),与标准CT测量几乎完全一致,提示其可用于实性结节容积测量。

要点

  • 血管抑制CT对实性肺结节半自动容积测量与标准CT一致性极高(CCC 0.990/0.985)。
  • 参考结节容积13–366 mm³,两名阅片者平均高估分别为标准CT 3 mm³、血管抑制CT 2.9 mm³。
  • 血管抑制CT与标准CT的阅片者间一致性界限分别为(16.3, -22.4 mm³)和(15.5, -21.4 mm³)。

核心结论

  • 血管抑制CT数据集可用于实性结节容积测量,阅片者间及与标准CT测量之间呈几乎完全一致。

研究设计与样本

  • 研究论文;93例标准CT经ClearRead CT(Riverain Technologies,Miamisburg,OH,USA)软件行血管抑制处理,比较65个实性结节的半自动容积测量;两名阅片者重复测量,以两名阅片者在标准CT上测量的平均容积作为参考标准值。

诊断标准与关键数值

  • 以两名阅片者在标准CT上测量的平均容积为参考标准值;血管抑制CT与参考标准的一致性Lin CCC为阅片者1 0.990、阅片者2 0.985;阅片者间测量一致性界限标准CT为(16.3, -22.4 mm³)、血管抑制CT为(15.5, -21.4 mm³)。

临床应用与阅片要点

  • 作者结论认为血管抑制CT数据集可行用于实性结节测量,阅片者间及与标准CT测量呈几乎完全一致。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate whether vessel-suppressed computed tomography (VSCT) can be reliably used for semi-automated volumetric measurements of solid pulmonary nodules, as compared to standard CT (SCT) MATERIAL AND METHODS: Ninety-three SCT were elaborated by dedicated software (ClearRead CT, Riverain Technologies, Miamisburg, OH, USA), that allows subtracting vessels from lung parenchyma. Semi-automated volumetric measurements of 65 solid nodules were compared between SCT and VSCT. The measurements were repeated by two readers. For each solid nodule, volume measured on SCT by Reader 1 and Reader 2 was averaged and the average volume between readers acted as standard of reference value. Concordance between measurements was assessed using Lin's Concordance Correlation Coefficient (CCC). Limits of agreement (LoA) between readers and CT datasets were evaluated.

RESULTS: Standard of reference nodule volume ranged from 13 to 366 mm3. The mean overestimation between readers was 3 mm3 and 2.9 mm3 on SCT and VSCT, respectively. Semi-automated volumetric measurements on VSCT showed substantial agreement with the standard of reference (Lin's CCC = 0.990 for Reader 1; 0.985 for Reader 2). The upper and lower LoA between readers' measurements were (16.3, -22.4 mm3) and (15.5, -21.4 mm3) for SCT and VSCT, respectively.

CONCLUSIONS: VSCT datasets are feasible for the measurements of solid nodules, showing an almost perfect concordance between readers and with measurements on SCT.

来源:Eur J Radiol,查看原文。版权归原作者所有。