前瞻性纳入 51 例患者共 119 个结节或肿块,对比 1 mm 层厚 CT 与 3T 超短回波时间(UTE)MRI(TE 192 μs,1 mm³ 分辨率)。UTE-MRI 对结节长轴径线系统性低估约 1–2 mm,但对亚实性密度、分叶、毛刺、胸膜牵拉及内部透亮区的诊断敏感度与特异度均较高,读者间一致性达中等至几乎完全一致。

要点

  • UTE-MRI 对结节长轴径线的测量较 CT 系统性低估约 1–2 mm,报告尺寸时需注意。
  • UTE-MRI 对亚实性密度的敏感度与特异度均高(敏感度 95.9%/97.1%,特异度 70.3%/71.4%)。
  • 分叶、毛刺、胸膜牵拉及内部透亮区的特异度高(≥93%),敏感度相对较低。

核心结论

  • UTE-MRI 系统性低估结节尺寸约 1–2 mm,但在结节形态学评估方面显示出高诊断效能和读者间一致性,为 MRI 前所未有。

研究设计与样本

  • 前瞻性研究,纳入 51 例患者共 119 个结节或肿块(平均大小 17.4±16.3 mm,范围 4–88 mm)。所有患者均接受 1 mm 层厚 CT 和 UTE-MRI(TE 192 μs,1 mm³ 分辨率)。两名放射科医师对 CT 采用共识评估,对 UTE-MRI 采用盲法评估结节尺寸和形态学特征(密度、边缘、内部透亮区)。以 CT 为参考标准计算敏感度、特异度和 kappa 统计量。

关键影像表现/征象

  • 两名读者采用 UTE-MRI 分别低估结节长轴径线 1.2±3.4 mm 和 2.1±4.2 mm(p<0.001)。
  • UTE-MRI 对亚实性密度的敏感度和特异度:读者 1 为 95.9% 和 70.3%,读者 2 为 97.1% 和 71.4%(κ=0.71 和 0.68)。
  • 分叶的敏感度读者 1 为 70.6%、读者 2 为 54.9%,特异度分别为 93.2% 和 96.3%。
  • 毛刺的敏感度读者 1 为 61.5%、读者 2 为 48.0%,特异度分别为 95.2% 和 95.0%;胸膜牵拉的敏感度读者 1 为 87.0%、读者 2 为 73.3%,特异度分别为 93.8% 和 95.0%。
  • 内部透亮区的敏感度读者 1 为 72.7%、读者 2 为 61.3%,特异度分别为 96.1% 和 97.3%(κ 读者 1 为 0.64–0.81,读者 2 为 0.48–0.72)。

诊断标准与关键数值

  • 以 CT 为参考标准,UTE-MRI 诊断亚实性密度的敏感度 95.9%(读者 1)和 97.1%(读者 2),特异度 70.3%(读者 1)和 71.4%(读者 2)。
  • 分叶的敏感度 70.6%(读者 1)和 54.9%(读者 2),特异度 93.2%(读者 1)和 96.3%(读者 2)。
  • 毛刺的敏感度 61.5%(读者 1)和 48.0%(读者 2),特异度 95.2%(读者 1)和 95.0%(读者 2)。
  • 胸膜牵拉的敏感度 87.0%(读者 1)和 73.3%(读者 2),特异度 93.8%(读者 1)和 95.0%(读者 2)。
  • 内部透亮区的敏感度 72.7%(读者 1)和 61.3%(读者 2),特异度 96.1%(读者 1)和 97.3%(读者 2)。

临床应用与阅片要点

  • 采用 UTE-MRI 评估肺结节时,应意识到其长轴径线测量较 CT 系统性低估约 1–2 mm。
  • UTE-MRI 对分叶、毛刺、胸膜牵拉和内部透亮区的特异度高,但敏感度相对较低,阳性发现可靠性较高。
  • 密度、边缘特征和内部透亮区的读者间一致性为中等至几乎完全一致(κ=0.51–0.90),少数例外。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Ultrashort TE (UTE) MRI has been shown to deliver high-resolution images comparable to CT images. Here we evaluate the potential of UTE-MRI for precise lung nodule characterization.

SUBJECTS AND METHODS: Fifty-one patients (mean [± SD] age, 68.7 ± 10.8 years) with 119 nodules or masses (mean size, 17.4 ± 16.3 mm; range, 4-88 mm) prospectively underwent CT (1-mm slice thickness) and UTE-MRI (TE, 192 μs; 1 mm3 resolution). Two radiologists assessed nodule dimensions and morphologic features (i.e., attenuation, margins, and internal lucencies), in consensus for CT and in a blinded fashion for UTE-MRI. Sensitivity, specificity, and kappa statistics were calculated in reference to CT.

RESULTS: Readers 1 and 2 underestimated the nodules' long axial diameter with UTEMRI by 1.2 ± 3.4 and 2.1 ± 4.2 mm, respectively (p < 0.001). The sensitivity and specificity of UTE-MRI for subsolid attenuation were 95.9% and 70.3%, respectively, for reader 1 and 97.1% and 71.4%, respectively, for reader 2 (κ = 0.71 and 0.68). With regard to margin characteristics, for lobulation, sensitivity was 70.6% and 54.9%, and specificity was 93.2% and 96.3% for readers 1 and 2, respectively; for spiculation, sensitivity was 61.5% and 48.0%, and specificity was 95.2% and 95.0%; and for pleural tags, sensitivity was 87.0% and 73.3%, and specificity was 93.8% and 95.0%. Finally, for internal lucencies, sensitivity was 72.7% and 61.3%, and specificity was 96.1% and 97.3% for readers 1 and 2, respectively (κ = 0.64-0.81 for reader 1 and 0.48-0.72 for reader 2). Interreader agreement for attenuation, margin characteristics, and lucencies was substantial to almost perfect with few exceptions (κ = 0.51-0.90).

CONCLUSION: UTE-MRI systematically underestimated dimension measurements by approximately 1-2 mm but otherwise showed high diagnostic properties and interreader agreement, yet unprecedented by MRI, for nodule morphologic assessment.