肺结节:在「咖啡休息」时间内评估恶性肿瘤的影像生物标志物
这项前瞻性队列研究纳入40例患者(20例不确定肺结节、20例肺转移瘤),在60分钟内完成两次低剂量CT(「咖啡休息」方案),评估CT纹理分析(CTTA)与半自动体积测量的可重复性。结果显示CTTA各特征95%CI在±17.8%以内,优于结节体积的±28.9%,且所有特征一致性相关系数在0.84至0.99之间;控制肺容积吸气组的所有测量可重复性均优于正常屏气组。
要点
- CTTA特征的可重复性优于结节体积测量(95%CI ±17.8% vs ±28.9%)。
- 所有CTTA特征一致性相关系数CCC在0.84至0.99之间,重复性高。
- 控制肺容积屏气组的各项测量可重复性均优于正常屏气组。
核心结论
- CTTA的可重复性与自动体积测量相当,采用控制容积屏气时似乎可提高可重复性。
研究设计与样本
- 前瞻性队列研究,纳入40例患者(20例不确定肺结节、20例肺转移瘤),在60分钟内完成两次低剂量CT扫描,并将患者随机分配至正常屏气组和控制肺容积组,从每个自动勾画的结节周围区域提取纹理特征。
关键影像表现/征象
- 两次扫描间结节体积平均差异为6.3%,标准差29.9%。
- CTTA纹理特征的95%CI在±17.8%以内,变异小于结节体积(95%CI ±28.9%)。
- 所有特征的一致性相关系数在0.84至0.99之间,重复性高。
- 控制肺容积组的所有测量可重复性均优于正常屏气组。
诊断标准与关键数值
- CTTA特征可重复性以一致性相关系数评估,范围为0.84至0.99。
- CTTA特征95%CI在±17.8%以内,结节体积95%CI为±28.9%。
- 两次扫描间结节体积平均差异为6.3%,标准差29.9%。
临床应用与阅片要点
- 原文结论指出CTTA可重复性与自动体积测量相当,控制容积屏气似乎可改善可重复性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: Although nodule volumetry is a recognized biomarker of malignancy in pulmonary nodules (PNs), caution is needed in its interpretation because of variables such as respiratory volume variation and inter-scan variability of up to 25%. CT Texture Analysis (CTTA) is a potential independent biomarker of malignancy but inter-scan variability and respiratory volume variation has not been assessed.
METHODS: In this prospective cohort study, 40 patients (20 with an indeterminate PN and 20 with pulmonary metastases) underwent two LDCTs within a 60-min period (the "Coffee-break") with the aim of assessing the repeatability of CTTA and semi-automated volume measurements. Texture features were extracted from each automatic contoured region surrounding the PN. Patients were also randomized to two inspiratory control groups: normal breath hold, and controlled lung volume to study the influence of inspiratory control on these measurements.
RESULTS: The mean difference in volume between the two scans was 6.3%,SD:29.9%. The textural features displayed 95% CI below ±17.8%, and were less variable than nodule volume (95%CI ± 28.9%). All features had high repeatability, calculated by the concordance correlation coefficient, (0.84 ≤ CCC ≤ 0.99). All measurements were more repeatable for the controlled lung volume group than the normal breath-hold group.
CONCLUSION: CTTA repeatability was comparable to automatic volumetric measurements, and appears to be improved using controlled volume breath holding.
引用
- Talwar A, Willaime JMY, Pickup LC, et al. Pulmonary nodules: Assessing the imaging biomarkers of malignancy in a "coffee-break". Eur J Radiol. 2018. PMID: 29571806. doi:10.1016/j.ejrad.2018.02.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。