文献速递胸部CT

胸部CT纹理分析用于系统性硬化症疗效评估

Chest CT texture analysis for response assessment in systemic sclerosis.
PubMed 文献 · Eur J Radiol · 2018-01-31

回顾性单中心分析23例接受自体干细胞移植的系统性硬化症患者,于移植前、移植后6个月和12个月行胸部CT,采用CT纹理分析(CTTA)并与半定量CT、肺功能及改良Rodnan皮肤评分对比。肺功能将18例(78%)归为应答者、5例(22%)为非应答者;应答者基线平均强度和偏度熵显著较低、偏度均匀性较高,两组CTTA参数在移植后6个月均有显著变化,仅应答者在12个月仍有显著变化。

要点

  • CTTA参数(平均强度、熵、均匀性)在移植后6个月于应答者与非应答者中均出现显著变化。
  • 基线时应答者较非应答者平均强度和偏度熵显著更低、偏度均匀性显著更高。
  • 非应答者纤维化评分在移植后6个月和12个月显著升高(2.33 ± 1.23 vs 1.41 ± 0.78,p = .005)。

核心结论

  • 自体干细胞移植后CT纹理特征的变化与视觉CT评估的系统性硬化症相关肺部异常相关,并补充提供治疗所致结构性肺改变的信息。

研究设计与样本

  • 回顾性单中心分析,纳入2005年7月至2016年11月间23例连续系统性硬化症患者(男11例),于自体干细胞移植前、移植后6个月和12个月行胸部CT,以肺功能、半定量胸部CT和改良Rodnan皮肤评分作对照。

关键影像表现/征象

  • 非应答者纤维化评分在移植后6个月和12个月显著升高(均值2.33 ± 1.23 vs 1.41 ± 0.78,p = .005)。
  • 应答者改良Rodnan皮肤评分在自体干细胞移植后6个月从28.46 ± 9.53改善至15.70 ± 10.07(p = .001),非应答者无显著改善。
  • 基线时应答者较非应答者平均强度和偏度熵显著更低、偏度均匀性显著更高。

诊断标准与关键数值

  • 疗效应答定义为移植后6个月FVC和DLCOSB稳定或改善均大于10%。
  • 肺功能将23例分为应答者18例(78%)和非应答者5例(22%)。

临床应用与阅片要点

  • CT纹理分析参数(平均、熵、均匀性)可与视觉CT评估互补,用于监测移植后治疗所致结构性肺改变。
  • 移植后6个月两组CTTA参数均有显著变化,仅应答者在12个月仍有显著变化。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the role of CT-textural features for monitoring lung involvement in subjects with systemic sclerosis(SSc) undergoing autologous stem cell transplantation(SCT) by comparison with semi-quantitative chest-CT, pulmonary function tests(PFT) and clinical parameters (modified Rodnan skin score[mRSS]).

METHODS: In a retrospective single centre analysis, we identified 23 consecutive subjects(11male) with SSc between 07/2005 and 11/2016 that underwent chest CTs before, 6 and 12 months post-SCT. Response to therapy was defined at 6 months after transplantation as stabilisation or improvement in FVC > 10% and DLCOSB > 10%. CT-texture analysis(CTTA) including mean, entropy and uniformity were calculated.

RESULTS: PFT classified the subjects into responders(18/23;78%) and non-responders(5/23;22%). mRSS improved in responders from 28.46 ± 9.53 to 15.70 ± 10.07 6 months after auto-SCT(p = .001) whereas in non-responders no significant improvement was registered. Fibrosis score increased significantly(mean2.33 ± 1.23 vs.1.41 ± 0.78; p = .005) in non-responders after 6 and 12months. Significant lower mean intensity and entropy of skewness and higher uniformity of skewness was found in responders vs. non-responders at baseline. Significant changes in CTTA-parameters were found in both responders and non-responders at 6months and only in responders also at 12months post-SCT.

CONCLUSIONS: Changes in CT-textural features after SCT are associated with visual CT evaluation of SSc-related lung abnormalities, but complementary provide information about therapy-induced, structural pulmonary changes.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Kloth C, Henes J, Xenitidis T, et al. Chest CT texture analysis for response assessment in systemic sclerosis. Eur J Radiol. 2018. PMID: 29571801. doi:10.1016/j.ejrad.2018.01.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。