超声引导下18G与20G粗针活检诊断甲状腺结节的效能比较
研究连续纳入81个20G和86个18G超声引导粗针活检的甲状腺结节,比较诊断效能、并发症与标本获取。18G非诊断性结果率更低(1.2% vs 8.6%,P=0.024),恶性诊断敏感度、阴性预测值和准确率数值更高但未达统计学显著,两组均无严重并发症,18G所需穿刺次数更少且标本直径更大。
要点
- 18G粗针活检的非诊断性结果率显著低于20G(1.2% vs 8.6%,P=0.024)。
- 18G对恶性诊断的敏感度75.0% vs 20G 66.7%、阴性预测值83.9% vs 75.9%、准确率78.3% vs 74.4%,均未达统计学显著。
- 两组均无严重并发症,18G穿刺次数更少且标本直径更大(P<0.001)。
核心结论
- 18G粗针活检对甲状腺结节的诊断可能比20G更有效。
研究设计与样本
- 回顾性比较连续甲状腺结节:20G组81个、18G组86个,均为2年内超声引导粗针活检,比较非诊断性结果率、恶性诊断效能、并发症率和标本获取。
关键影像表现/征象
- 18G粗针活检的非诊断性结果率为1.2%,20G为8.6%(P=0.024)。
- 18G组粗针穿刺次数显著少于20G组,标本直径显著大于20G组(P<0.001)。
诊断标准与关键数值
- 非诊断性结果率:18G 1.2% vs 20G 8.6%(P=0.024)。
- 恶性诊断敏感度:18G 75.0% vs 20G 66.7%,未达统计学显著。
- 恶性诊断阴性预测值:18G 83.9% vs 20G 75.9%,未达统计学显著。
- 恶性诊断准确率:18G 78.3% vs 20G 74.4%,未达统计学显著。
- 意义不明确的异型性/滤泡性病变率及总的不确定结果率两组间无显著差异(P>0.05)。
临床应用与阅片要点
- 18G粗针可降低非诊断性结果率并获取更大直径标本,可能减少因标本不足导致的重复穿刺。
- 18G与20G在意义不明确的异型性/滤泡性病变率上无显著差异。
- 两组均无严重并发症。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the diagnostic efficacy, complication rate, and core needle biopsy (CNB) specimen yield in 18- versus 20-gauge ultrasound (US)-guided CNB for diagnosis of thyroid nodules.
METHODS: We included 81 consecutive thyroid nodules with US-guided biopsy by a 20-gauge core needle and 86 consecutive thyroid nodules with US-guided biopsy by an 18-gauge core needle during 2 years. The rate of inconclusive results, including nondiagnostic or atypia/follicular lesion of undetermined significance, was compared. The diagnostic performance for malignancy was assessed in nodules with a final diagnosis. The complication rate and CNB specimen yield were also compared.
RESULTS: Eighteen-gauge CNB showed a lower rate of nondiagnostic results (1.2% versus 8.6%; P = .024) than 20-gauge CNB; however, the rates of atypia/follicular lesion of undetermined significance and inconclusive results were not significantly different between the groups (P > .05). In addition, 18-gauge CNB showed higher sensitivity (75.0% versus 66.7%), a higher negative predictive value (83.9% versus 75.9%), and higher accuracy (78.3% versus 74.4%) for detecting malignancy than 20-gauge CNB, although the results did not achieve statistical significance. No major complications occurred in either of the CNB groups. The 18-gauge needle group had significantly fewer CNBs and larger specimen diameters (P < .001).
CONCLUSIONS: Core needle biopsy with an 18-gauge needle could be more effective for the diagnosis of thyroid nodules than CNB with a 20-gauge needle.
引用
- Ahn HS, Seo M, Ha SM, et al. Comparison of the Diagnostic Efficacy of Ultrasound-Guided Core Needle Biopsy With 18- Versus 20-Gauge Needles for Thyroid Nodules. J Ultrasound Med. 2018. PMID: 29575135. doi:10.1002/jum.14614
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。