文献速递神经外周血管MR

基于磁共振成像的患者特异性计算流体动力学模拟用于评估床突旁颈内动脉动脉瘤起始的血流动力学血管生物标志物

Hemodynamic vascular biomarkers for initiation of paraclinoid internal carotid artery aneurysms using patient-specific computational fluid dynamic simulation based on magnetic resonance imaging.
PubMed 文献 · Neuroradiology · 2018-03-08

本研究对35例患者(15个有动脉瘤的床突旁颈内动脉为A组,15个对侧无动脉瘤为B组,33个无动脉瘤及动脉硬化病变的床突旁颈内动脉为C组)进行基于MR数据的计算流体动力学模拟,评估动脉瘤起始部位血管生物标志物分布;结果显示A组归一化最高壁面剪应力和归一化最高空间壁面剪应力梯度显著高于C组,且A组归一化最高空间壁面剪应力梯度显著高于B组,提示两者是动脉瘤起始的良好生物标志物。

要点

  • 床突旁颈内动脉动脉瘤起始部位及附近可见高壁面剪应力和高空间壁面剪应力梯度分布。
  • A组归一化最高壁面剪应力和归一化最高空间壁面剪应力梯度显著高于C组。
  • A组归一化最高空间壁面剪应力梯度显著高于B组。

核心结论

  • 归一化最高壁面剪应力和归一化最高空间壁面剪应力梯度是床突旁颈内动脉动脉瘤起始的良好生物标志物。

研究设计与样本

  • 对35例随访动脉瘤的患者行3D时间飞跃法磁共振血管成像和3D cine相位对比磁共振成像,基于MR数据行计算流体动力学模拟;A组为15个有动脉瘤的床突旁颈内动脉,B组为15个对侧无动脉瘤的床突旁颈内动脉,C组为33个无动脉瘤及动脉硬化病变的床突旁颈内动脉。

关键影像表现/征象

  • A组动脉瘤起始部位及附近可见高壁面剪应力和高空间壁面剪应力梯度分布。
  • B组和C组在相似位置也可见高壁面剪应力和高空间壁面剪应力梯度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We performed computational fluid dynamics (CFD) for patients with and without paraclinoid internal carotid artery (ICA) aneurysms to evaluate the distribution of vascular biomarkers at the aneurysm initiation sites of the paraclinoid ICA.

METHODS: This study included 35 patients who were followed up for aneurysms using 3D time of flight (TOF) magnetic resonance angiography (MRA) and 3D cine phase-contrast MR imaging. Fifteen affected ICAs were included in group A with the 15 unaffected contralateral ICAs in group B. Thirty-three out of 40 paraclinoid ICAs free of aneurysms and arteriosclerotic lesions were included in group C. We deleted the aneurysms in group A based on the 3D TOF MRA dataset. We performed CFD based on MR data set and obtained wall shear stress (WSS), its derivatives, and streamlines. We qualitatively evaluated their distributions at and near the intracranial aneurysm initiation site among three groups. We also calculated and compared the normalized highest (nh-) WSS and nh-spatial WSS gradient (SWSSG) around the paraclinoid ICA among three groups.

RESULTS: High WSS and SWSSG distribution were observed at and near the aneurysm initiation site in group A. High WSS and SWSSG were also observed at similar locations in group B and group C. However, nh-WSS and nh-SWSSG were significantly higher in group A than in group C, and nh-SWSSG was significantly higher in group A than in group B.

CONCLUSION: Our findings indicated that nh-WSS and nh-SWSSG were good biomarkers for aneurysm initiation in the paraclinoid ICA.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Watanabe T, Isoda H, Takehara Y, et al. Hemodynamic vascular biomarkers for initiation of paraclinoid internal carotid artery aneurysms using patient-specific computational fluid dynamic simulation based on magnetic resonance imaging. Neuroradiology. 2018. PMID: 29520642. doi:10.1007/s00234-018-2002-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。