动脉瘤载瘤动脉特异性流入条件:适用于完整与不完整Willis环构型
本研究对96例患者共103个动脉瘤,采用2D相位对比MR测量载瘤动脉流速,并用MRA评估Willis环构型;发现不同载瘤动脉及完整/不完整Willis环构型间流入条件差异显著,并据此建立了载瘤动脉特异性流入条件库,供未来计算流体力学研究使用。
要点
- 不完整Willis环构型见于24%的病例。
- P1段发育不良时基底动脉流量显著降低。
- 对侧A1段发育不良时A1段流量显著升高。
核心结论
- 载瘤动脉间及不同Willis环构型间流入条件差异显著,已建立针对患者特异性Willis环构型的载瘤动脉特异性流入条件库,可用于未来分析动脉瘤内血流动力学的计算流体力学研究。
研究设计与样本
- 研究纳入96例患者共103个动脉瘤,采用2D相位对比MR垂直于Willis环内载瘤动脉测量流速,并用多层重叠薄层采集MRA评估Willis环构型变异,计算各载瘤动脉位置的流量、速度幅值和搏动指数。
诊断标准与关键数值
- 不完整Willis环构型见于24%的病例。
- P1段发育不良的构型中基底动脉流量显著降低。
- 对侧A1段发育不良的构型中A1段流量显著升高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Hemodynamics are thought to play a role in intracranial aneurysm growth and rupture. Computational fluid dynamics is frequently performed to assess intra-aneurysmal hemodynamics, using generalized flow waveforms of healthy volunteers as inflow boundary conditions. The purpose of this study was to assess differences in inflow conditions for different aneurysmal parent artery locations and variations of circle of Willis configurations.
MATERIALS AND METHODS: In a series of 96 patients with 103 aneurysms, velocity measurements were acquired using 2D phase-contrast MR imaging perpendicular to the aneurysmal parent arteries in the circle of Willis. Circle of Willis configurations were inspected for variations using multiple overlapping thin-slab-acquisition MRAs. Flow rates, velocity magnitudes, and pulsatility indices were calculated for each parent artery location in subgroups of complete and incomplete circle of Willis configurations.
RESULTS: Flow rates, velocity magnitudes, and pulsatility indices were significantly different among aneurysmal parent arteries. Incomplete circle of Willis configurations were observed in 24% of the cases. Significantly lower basilar artery flow rates were observed in configurations with hypoplastic P1 segments. Significantly higher A1 flow rates were observed in configurations with a hypoplastic contralateral A1 segment.
CONCLUSIONS: Inflow conditions vary substantially between aneurysmal parent arteries and circle of Willis configurations. We have created a collection of parent artery-specific inflow conditions tailored to the patient-specific circle of Willis configuration that can be used in future computational fluid dynamics studies analyzing intra-aneurysmal hemodynamics.
引用
- Cornelissen BMW, Schneiders JJ, Sprengers ME, et al. Aneurysmal Parent Artery-Specific Inflow Conditions for Complete and Incomplete Circle of Willis Configurations. AJNR Am J Neuroradiol. 2018. PMID: 29599169. doi:10.3174/ajnr.A5602
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。