文献速递技术与安全PETCT

肿瘤负荷对PET显像参考组织标准化摄取的影响:对PERCIST标准的修正

Effects of Tumor Burden on Reference Tissue Standardized Uptake for PET Imaging: Modification of PERCIST Criteria.
PubMed 文献 · Radiology · 2018-03-20

回顾性分析107例PET/CT扫描,以总病灶糖酵解量(TLG)评估代谢组织负荷,发现参考组织(血池、肝脏、脑)的FDG摄取与TLG呈负相关(P<.0001);将FDG摄取标准化至参考组织后,该效应不再有统计学意义(P>.05),提示PERCIST标准中参考组织标准化可减轻肿瘤负荷的影响。

要点

  • 肿瘤及心肌代谢负荷增大时,血池、肝脏、脑的FDG摄取随TLG升高而降低(P<.0001)。
  • 将FDG摄取标准化至参考组织(如血池或肝脏)后,TLG效应不再有统计学意义(P>.05)。
  • PERCIST标准采用参考组织标准化可能减轻代谢负荷对SUV测量的影响。

核心结论

  • 代谢组织负荷可显著影响PET显像的SUV测量,将FDG摄取标准化至参考组织可减轻该效应。

研究设计与样本

  • 回顾性研究,纳入2015年1月至7月Ann Arbor退伍军人事务医院107例PET/CT扫描(50例患者,平均年龄64.3岁±13.2),并以既往报道的229例患者436例FDG PET/CT扫描作为对照,采用线性混合效应模型回归分析。

关键影像表现/征象

  • 参考组织(血池、肝脏、脑)的FDG摄取与总病灶糖酵解量(TLG)呈负相关(P<.0001)。
  • 将FDG摄取标准化至参考组织(如血池或肝脏)后,TLG效应不再有统计学意义(P>.05)。

诊断标准与关键数值

  • 以总病灶糖酵解量(TLG)作为代谢组织负荷的评估指标,由肿瘤和/或心脏组织自动分割获得。
  • 回归斜率显著偏离零(P<.05)即判定存在TLG效应。

临床应用与阅片要点

  • 阅片及报告SUV时需注意肿瘤及心肌代谢负荷可能影响参考组织摄取,采用参考组织标准化可减轻该影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To examine the effect metabolic burden (tumor and/or cardiac myocyte uptake) has on fluorine 18 fluorodeoxyglucose (FDG) distribution in organs and tissues of interest. Materials and Methods Positron emission tomographic (PET)/computed tomographic (CT) scans at the Ann Arbor Veterans Affairs hospital from January to July 2015 were reviewed. A total of 107 scans (50 patients; mean age, 64.3 years ± 13.2 [standard deviation]) had metabolic tissue burden assessed by using total lesion glycolysis (TLG) obtained from autosegmentation of the tumor and/or cardiac tissue. Standardized uptake value (SUV) and subsequent normalized SUV uptake in target organs and tissues were compared with 436 FDG PET/CT scans previously reported in 229 patients as a function of TLG to describe the effect(s) that metabolic burden has on reference tissue (blood pool, liver, and brain) FDG uptake. Subsequent regression by using linear mixed-effects models was used. If the slope of the regression was significantly (P < .05) different than zero, then an effect from TLG was present. Results There was a negative inverse relationship (P < .0001) between FDG uptake within reference tissues (blood pool, liver, and brain) and TLG in comparison to the study population at similar blood glucose levels. This TLG effect was no longer statistically significant (P > .05) when FDG uptake was normalized to a reference tissue (eg, blood pool or liver). Conclusion Metabolic tissue burden can have a significant effect on SUV measurements for PET imaging. This effect can be mitigated by normalizing FDG uptake to a reference tissue. © RSNA, 2018.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Viglianti BL, Wale DJ, Wong KK, et al. Effects of Tumor Burden on Reference Tissue Standardized Uptake for PET Imaging: Modification of PERCIST Criteria. Radiology. 2018. PMID: 29558296. doi:10.1148/radiol.2018171356