文献速递神经头颈外周血管CTDSA

90 kVp 低管电压颈动脉与颅内 CT 血管成像的诊断效能:对辐射剂量、图像质量及颈动脉狭窄检出能力的影响

Diagnostic yield of 90-kVp low-tube-voltage carotid and intracerebral CT-angiography: effects on radiation dose, image quality and diagnostic performance for the detection of carotid stenosis.
PubMed 文献 · Br J Radiol · 2018-03-08

回顾性分析 43 例患者的双能 CTA 资料,个体内比较 90 kVp 与线性融合 120 kVp 等效序列(M_0.6)。90 kVp 序列信噪比与对比噪声比更高,图像质量与 M_0.6 相当,颈动脉狭窄检出与分级一致性极好(组内相关系数 0.94),剂量长度乘积降低 40.3%。

要点

  • 90 kVp 联合 Admire 重建在颈动脉与颅内 CTA 中提供更高的对比噪声比,图像质量与 120 kVp 等效序列相当。
  • 颈动脉狭窄检出与分级两种序列一致性极好,观察者间组内相关系数 0.94。
  • 90 kVp 序列剂量长度乘积较 M_0.6 降低 40.3%(110.6 ± 32.1 vs 185.4 ± 47.5 mGy·cm,p < 0.001)。

核心结论

  • 90 kVp 颈动脉与颅内 CTA 联合 Admire 重建可提高定量图像质量、保持定性图像质量并大幅降低辐射剂量,动脉狭窄检出与定量诊断效能依然优秀。

研究设计与样本

  • 回顾性评估 43 例患者的双能 CTA 资料,使用第三代 192 层双源 CT,个体内比较 90 kVp 与线性融合 120 kVp 等效序列(M_0.6,60% 90 kVp 与 40% Sn-150 kVp 融合)。

关键影像表现/征象

  • 90 kVp 序列所有动脉的对比噪声值较 M_0.6 显著增高(p < 0.001)。
  • 两序列在肩部、颈动脉分叉、虹吸段及颅内水平的伪影均少,适合血管造影评估的评级均为优秀。
  • 129 个颈动脉节段中检出 32 处狭窄,两序列检出与分级一致性极好,观察者间组内相关系数 0.94。

诊断标准与关键数值

  • 以双能 CTA 线性融合 120 kVp 等效序列 M_0.6 为对照,90 kVp 序列对颈动脉狭窄检出与分级显示极好一致性,组内相关系数 0.94。
  • 共评估 129 个颈动脉节段,检出 32 处狭窄,两序列诊断一致性优秀。

临床应用与阅片要点

  • 90 kVp 联合 Admire 重建可用于颈动脉与颅内 CTA,在保持狭窄评估诊断效能的同时显著降低辐射剂量。
  • 两序列在肩部、颈动脉分叉、虹吸段及颅内水平伪影均少且适合血管造影评估,日常阅片可放心采用 90 kVp 方案。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the impact of low-tube-voltage 90-kVp acquisition combined with advanced modeled iterative reconstruction algorithm (Admire) on radiation exposure, image quality, artifacts, and assessment of stenosis in carotid and intracranial CT angiography (CTA).

METHODS: Dual-energy CTA studies of 43 patients performed on a third-generation 192-slice dual-source CT were retrospectively evaluated. Intraindividual comparison of 90-kVp and linearly blended 120-kVp equivalent image series (M_0.6, 60% 90-kVp, 40% Sn-150-kVp) was performed. Contrast-to-noise and signal-to-noise ratios of common carotid artery, internal carotid artery, middle cerebral artery, and basilar artery were calculated. Qualitative image analysis included evaluation of artifacts and suitability for angiographical assessment at shoulder level, carotid bifurcation, siphon, and intracranial by three independent radiologists. Detection and quantification of carotid stenosis were performed. Radiation dose was expressed as dose-length product (DLP).

RESULTS: Contrast-to-noise values of all arteries were significantly increased in 90-kVp compared to M_0.6 (p < 0.001). Suitability for angiographical evaluation was rated excellent with low artifacts for all levels in both image series. Both 90-kVp and M_0.6 showed excellent accordance for detection and grading of carotid stenosis with almost perfect interobserver agreement (carotid stenoses in 32 of 129 segments; intraclass correlation coefficient, 0.94). dose-length product was reduced by 40.3% in 90-kVp (110.6 ± 32.1 vs 185.4 ± 47.5 mGy·cm, p < 0.001).

CONCLUSION: 90-kVp carotid and intracranial CTA with Admire provides increased quantitative and similarly good qualitative image quality, while reducing radiation exposure substantially compared to M_0.6. Diagnostic performance for arterial stenosis detection and quantification remained excellent. Advances in knowledge: 90-kVp carotid and intracranial CTA with an advanced iterative reconstruction algorithm results in excellent image quality and reduction of radiation exposure without limiting diagnostic performance.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Leithner D, Wichmann JL, Mahmoudi S, et al. Diagnostic yield of 90-kVp low-tube-voltage carotid and intracerebral CT-angiography: effects on radiation dose, image quality and diagnostic performance for the detection of carotid stenosis. Br J Radiol. 2018. PMID: 29493282. doi:10.1259/bjr.20170927

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。