最新一代平板探测器CT诊断早期缺血性改变:与多探测器CT的对比研究
本研究前瞻性分析25例大血管闭塞并接受机械取栓的缺血性卒中患者,比较最新一代平板探测器CT与多探测器CT基于ASPECTS诊断早期缺血征象的表现。平板探测器CT与多探测器CT的ASPECTS呈强相关(r=0.849,P<.001),总体敏感度85.1%、特异度83.1%,两者对功能结局的预测价值相似。作者认为平板探测器CT用于取栓前急诊卒中成像可行,可缩短door-to-groin时间。
要点
- 平板探测器CT与多探测器CT的ASPECTS强相关(r=0.849,P<.001),诊断早期缺血改变敏感度85.1%、特异度83.1%。
- 24/25例(96%)平板探测器CT图像诊断质量充分,中位ASPECTS为7分(多探测器CT IQR 5.5-9,平板探测器CT IQR 4.25-8)。
- 平板探测器CT与多探测器CT的ASPECTS对功能结局预测价值相似(AUC 0.738,P=.007 vs 0.715,P=.069)。
核心结论
- 平板探测器CT测定ASPECTS可行,与多探测器CT的ASPECTS无显著差异,且对功能结局的预测价值相似;研究结果支持在机械取栓前使用平板探测器CT进行急诊卒中成像以缩短door-to-groin时间。
研究设计与样本
- 单中心前瞻性衍生数据分析,纳入25例大血管闭塞并接受机械取栓的缺血性卒中患者,所有患者转至综合卒中中心前接受多探测器CT、取栓前在血管造影室接受平板探测器CT,以多探测器CT ASPECTS为参考技术进行比较。
诊断标准与关键数值
- 以多探测器CT ASPECTS为参考,平板探测器CT ASPECTS总体敏感度85.1%、特异度83.1%;两者ASPECTS强相关(r=0.849,P<.001);多探测器CT与平板探测器CT的ASPECTS对功能结局的AUC分别为0.738(P=.007)与0.715(P=.069)。
临床应用与阅片要点
- 作者认为平板探测器CT用于机械取栓前急诊卒中成像可行,可缩短door-to-groin时间;两次检查中位间隔143.6±49.5分钟,中位多探测器CT ASPECTS为7(IQR 5.5-9),中位平板探测器CT ASPECTS为7(IQR 4.25-8)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: One-stop management of mechanical thrombectomy-eligible patients with large-vessel occlusion represents an innovative approach in acute stroke treatment. This approach reduces door-to-reperfusion times by omitting multidetector CT, using flat detector CT as pre-mechanical thrombectomy imaging. The purpose of this study was to compare the diagnostic performance of the latest-generation flat detector CT with multidetector CT.
MATERIALS AND METHODS: Prospectively derived data from patients with ischemic stroke with large-vessel occlusion and mechanical thrombectomy were analyzed in this monocentric study. All included patients underwent multidetector CT before referral to our comprehensive stroke center and flat detector CT in the angiography suite before mechanical thrombectomy. Diagnosis of early ischemic signs, quantified by the ASPECTS, was compared between modalities using cross tables, the Pearson correlation, and Bland-Altman plots. The predictive value of multidetector CT- and flat detector CT-derived ASPECTS for functional outcome was investigated using area under the receiver operating characteristic curve analysis.
RESULTS: Of 25 patients, 24 (96%) had flat detector CT with sufficient diagnostic quality. Median multidetector CT and flat detector CT ASPECTSs were 7 (interquartile range, 5.5-9 and 4.25-8, respectively) with a mean period of 143.6 ± 49.5 minutes between both modalities. The overall sensitivity was 85.1% and specificity was 83.1% for flat detector CT ASPECTS compared with multidetector CT ASPECTS as the reference technique. Multidetector CT and flat detector CT ASPECTS were strongly correlated (r = 0.849, P < .001) and moderately predicted functional outcome (area under the receiver operating characteristic curve, 0.738; P = .007 and .715; P = .069, respectively).
CONCLUSIONS: Determination of ASPECTS on flat detector CT is feasible, showing no significant difference compared with multidetector CT ASPECTS and a similar predictive value for functional outcome. Our findings support the use of flat detector CT for emergency stroke imaging before mechanical thrombectomy to reduce door-to-groin time.
引用
- Maier IL, Leyhe JR, Tsogkas I, et al. Diagnosing Early Ischemic Changes with the Latest-Generation Flat Detector CT: A Comparative Study with Multidetector CT. AJNR Am J Neuroradiol. 2018. PMID: 29567653. doi:10.3174/ajnr.A5595
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。