文献速递神经外周血管MRDSA

动脉自旋标记可改善MRI对颅内硬脑膜动静脉瘘的检测

Arterial Spin-Labeling Improves Detection of Intracranial Dural Arteriovenous Fistulas with MRI.
PubMed 文献 · AJNR Am J Neuroradiol · 2018-03-15

本回顾性研究纳入39例硬脑膜动静脉瘘患者和117例对照,评估3D伪连续动脉自旋标记MRI检测该病的准确性和附加价值。静脉动脉自旋标记信号诊断硬脑膜动静脉瘘的敏感度为94%、特异度为88%,加入伪连续动脉自旋标记后诊断性能较结构MRI显著提高(ΔAUC=0.179),观察者间一致性几乎完美(κ=0.92)。

要点

  • 静脉动脉自旋标记信号诊断硬脑膜动静脉瘘敏感度94%、特异度88%。
  • 加入伪连续动脉自旋标记较结构MRI的AUC提高0.179,较结构MRI联合TOF-MRA提高0.043。
  • 加入伪连续动脉自旋标记后观察者间一致性几乎完美(κ=0.92)。

核心结论

  • 静脉动脉自旋标记信号对硬脑膜动静脉瘘的存在具有高敏感度和特异度,加入伪连续动脉自旋标记可提高MRI诊断该病的信心。

研究设计与样本

  • 回顾性研究纳入39例硬脑膜动静脉瘘患者和117例对照,均行DSA和含伪连续动脉自旋标记的MRI;由两名对DSA结果不知情的神经放射科医生独立评估含与不含伪连续动脉自旋标记的MRI,采用5点Likert量表记录特定征象(包括静脉动脉自旋标记信号)及硬脑膜动静脉瘘可能性。

关键影像表现/征象

  • 静脉动脉自旋标记信号是诊断硬脑膜动静脉瘘的特定征象,敏感度94%、特异度88%。

诊断标准与关键数值

  • 静脉动脉自旋标记信号诊断硬脑膜动静脉瘘的敏感度94%、特异度88%。
  • 加入伪连续动脉自旋标记较结构MRI的AUC提高0.179(ΔAUC=0.179)。
  • 加入伪连续动脉自旋标记较结构MRI联合TOF-MRA的AUC提高0.043(ΔAUC=0.043),仅为改善趋势。
  • 加入伪连续动脉自旋标记后观察者间一致性几乎完美(κ=0.92)。

临床应用与阅片要点

  • 阅片时可关注静脉动脉自旋标记信号这一征象,其诊断硬脑膜动静脉瘘的敏感度94%、特异度88%。
  • 在结构MRI和TOF-MRA基础上加入伪连续动脉自旋标记,可提高诊断硬脑膜动静脉瘘的信心。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Intracranial dural arteriovenous fistulas carry a risk of substantial neurologic complications but can be difficult to detect on structural MR imaging and TOF-MRA. The purpose of this study was to assess the accuracy and added value of 3D pseudocontinuous arterial spin-labeling MR imaging for the detection of these lesions.

MATERIALS AND METHODS: This retrospective study included 39 patients with a dural arteriovenous fistula and 117 controls who had undergone both DSA and MR imaging with pseudocontinuous arterial spin-labeling. Two neuroradiologists blinded to the DSA results independently assessed MR imaging with and without pseudocontinuous arterial spin-labeling. They recorded specific signs, including venous arterial spin-labeling signal, and the likelihood of a dural arteriovenous fistula using a 5-point Likert scale. Logistic regression and receiver operating characteristic analyses were performed to determine the accuracy of specific signs and the added value of pseudocontinuous arterial spin-labeling. Interobserver agreement was determined by using κ statistics.

RESULTS: Identification of the venous arterial spin-labeling signal had a high sensitivity (94%) and specificity (88%) for the presence a dural arteriovenous fistula. Receiver operating characteristic analysis showed significant improvement in diagnostic performance with the addition of pseudocontinuous arterial spin-labeling in comparison with structural MR imaging (Δarea under the receiver operating characteristic curve = 0.179) and a trend toward significant improvement in comparison with structural MR imaging with time-of-flight MRA (Δarea under the receiver operating characteristic curve = 0.043). Interobserver agreement for the presence of a dural arteriovenous fistula improved substantially and was almost perfect with the addition of pseudocontinuous arterial spin-labeling (κ = 0.92).

CONCLUSIONS: Venous arterial spin-labeling signal has high sensitivity and specificity for the presence of a dural arteriovenous fistula, and the addition of pseudocontinuous arterial spin-labeling increases confidence in the diagnosis of this entity on MR imaging.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Amukotuwa SA, Marks MP, Zaharchuk G, et al. Arterial Spin-Labeling Improves Detection of Intracranial Dural Arteriovenous Fistulas with MRI. AJNR Am J Neuroradiol. 2018. PMID: 29545245. doi:10.3174/ajnr.A5570

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。