虚拟CT结肠成像:第三代双源扫描仪锡过滤技术实现亚毫西弗检查的二维与虚拟三维图像质量评估

Virtual Computed Tomography Colonography: Evaluation of 2D and Virtual 3D Image Quality of Sub-mSv Examinations Enabled by Third-generation Dual Source Scanner Featuring Tin Filtering.
PubMed 文献 · Acad Radiol · 2018-01-19

回顾性评估26例第三代双源CT结肠成像患者,9例采用标准剂量方案、17例采用锡过滤低剂量方案。低剂量方案有效剂量0.75 ± 0.16 mSv,显著低于标准剂量方案的3.00 ± 0.40 mSv(P < .001),主观图像质量无显著差异(P = .661),所有检查诊断信心均为「优秀」或「良好」。结论认为锡过滤技术可实现稳定的亚毫西弗结肠成像而不明显损害图像质量。

要点

  • 低剂量方案有效剂量0.75 ± 0.16 mSv,显著低于标准剂量方案3.00 ± 0.40 mSv(P < .001)。
  • 主观图像质量两组无显著差异(P = .661),所有检查诊断信心均为「优秀」或「良好」。
  • 信噪比标准剂量方案8.9 ± 2.1,低剂量方案4.9 ± 0.8。

核心结论

  • 第三代双源CT锡过滤技术可实现稳定的亚毫西弗结肠成像,而不明显损害图像质量。

研究设计与样本

  • 回顾性评估26例连续接受第三代双源CT结肠成像的患者,其中9例采用标准剂量临床扫描方案、17例采用锡过滤低剂量方案。

诊断标准与关键数值

  • 主观图像质量两组无显著差异(P = .661),所有检查诊断信心均为「优秀」或「良好」。
  • 信噪比在标准剂量方案为8.9 ± 2.1,在低剂量方案为4.9 ± 0.8。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate two- and three-dimensional (2D and 3D) image quality of sub-milliSievert (mSv) computed tomography (CT) colonography utilizing a third-generation dual source CT scanner featuring a tin filter.

METHODS: We retrospectively evaluated 26 consecutive patients who underwent third-generation dual source CT colonography, nine with the standard-dose clinical-scan protocol (SDP) and 17 with a low-dose protocol (LDP) featuring a tin filter. Radiation dose was evaluated by volume computed tomography dose index (CTDIvol), dose length product (DLP), effective dose (E), and size-specific dose estimate. Objective image quality was evaluated utilizing signal-to-noise ratio (SNR) derived from standardized placed regions of interest on the transverse 2D images and the ratio of SNR/CTDIvol (normalized SNR). Two radiologists in consensus assessed subjective image quality of the virtual 3D images.

RESULTS: There were no significant differences in subjective image quality (P = .661). All examinations were rated "excellent" or "good" for diagnostic confidence. The mean total for DLP/E was 143.4 ± 29.8 mGy/3.00 ± 0.40 mSv in the SDP and therefore significantly higher than in the LDP with 36.9 ± 8.7 mGy/0.75 ± 0.16 mSv (P < .001). The SNR was 8.9 ± 2.1 in the SDP and 4.9 ± 0.8 in the LDP.

CONCLUSIONS: Third-generation dual source CT featuring a tin filter enables consistent sub-mSv colonography without substantially impairing image quality.