氟磁共振成像监测高强度聚焦超声消融后肿瘤炎症
研究用19F磁共振成像在BALB/c小鼠4T1皮下肿瘤模型中纵向定量监测高强度聚焦超声(HIFU)诱导的巨噬细胞浸润。HIFU组肿瘤内平均19F信号在消融后第4天前显著高于对照组(0.82±0.26 vs 0.42±0.17,P<.001);HIFU+氯膦酸盐组从第4天(0.82±0.23,P<.001)至第14天(0.55±0.16 vs 0.28±0.06,P<.05)高于对照组。结论认为19F MR成像可在临床前肿瘤模型中纵向捕获并定量HIFU诱导的巨噬细胞浸润。
要点
- 19F信号见于肿瘤边缘及消融灶周边,HIFU后第4天前HIFU组显著高于对照组(P<.001)。
- HIFU+氯膦酸盐组19F信号从第4天至第14天均高于对照组(第14天0.55±0.16 vs 0.28±0.06,P<.05)。
- 组织学见消融灶周围巨噬细胞浸润,免疫荧光证实PFC标记巨噬细胞。
核心结论
- 19F MR成像可在临床前肿瘤模型中纵向捕获并定量HIFU诱导的巨噬细胞浸润。
研究设计与样本
- 临床前动物实验:BALB/c小鼠皮下接种4T1细胞,分为对照组(n=9)、HIFU组(n=9)、HIFU+氯膦酸盐组(n=9);HIFU后即刻静脉注射全氟化碳乳剂,于HIFU后第2、4、7、10、14天行MR成像,并以组织学和免疫荧光验证。
关键影像表现/征象
- 19F信号见于肿瘤边缘和消融灶周边;组织学显示消融灶周围巨噬细胞浸润,免疫荧光证实全氟化碳标记巨噬细胞。
诊断标准与关键数值
- HIFU组 vs 对照组肿瘤内平均19F信号:第4天前0.82±0.26 vs 0.42±0.17,P<.001。
- HIFU+氯膦酸盐组 vs 对照组:第4天0.82±0.23,P<.001;第14天0.55±0.16 vs 0.28±0.06,P<.05。
临床应用与阅片要点
- 作者结论认为19F MR成像可在临床前肿瘤模型中纵向捕获并定量HIFU诱导的巨噬细胞浸润。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To investigate whether high-intensity focused ultrasound (HIFU)-induced macrophage infiltration could be longitudinally monitored with fluorine 19 (19F) magnetic resonance (MR) imaging in a quantitative manner. Materials and Methods BALB/c mice were subcutaneously inoculated with 4T1 cells and were separated into three groups: untreated mice (control, n = 9), HIFU-treated mice (HIFU, n = 9), and HIFU- and clodronate-treated mice (HIFU+Clod, n = 9). Immediately after HIFU treatment, all mice were intravenously given perfluorocarbon (PFC) emulsion. MR imaging examinations were performed 2, 4, 7, 10, and 14 days after HIFU treatment. Two-way repeated measures analysis of variance was used to analyze the changes in 19F signal over time and differences between groups. Histologic examinations were performed to confirm in vivo data. Results Fluorine 19 signals were detected at the rims of tumors and the peripheries of ablated lesions. Mean 19F signal in tumors was significantly higher in HIFU-treated mice than in control mice up to day 4 (0.82 ± 0.26 vs 0.42 ± 0.17, P < .001). Fluorine 19 signals were higher in the HIFU+Clod group than in the control group from day 4 (0.82 ± 0.23, P < .001) to day 14 (0.55 ± 0.16 vs 0.28 ± 0.06, P < .05). Histologic examination revealed macrophage infiltration around ablated lesions. Immunofluorescence staining confirmed PFC labeling of macrophages. Conclusion Fluorine 19 MR imaging can longitudinally capture and quantify HIFU-induced macrophage infiltration in preclinical tumor models. © RSNA, 2018 Online supplemental material is available for this article.
引用
- Shin SH, Park SH, Kim SW, et al. Fluorine MR Imaging Monitoring of Tumor Inflammation after High-Intensity Focused Ultrasound Ablation. Radiology. 2018. PMID: 29369752. doi:10.1148/radiol.2017171603
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。