髋关节MR关节造影:三维稳态自由进动序列与二维涡轮自旋回波序列的诊断效能与图像质量比较
回顾性纳入81例疑似髋关节盂唇撕裂患者,在3T扫描仪上行髋关节MR关节造影,比较各向同性3D-SSFP与2D-TSE-PD fs序列。以关节镜为参考标准(39例),3D-SSFP对盂唇和软骨病变的敏感度相似(85.9%),特异度更高(74.4% vs 42.9%),且采集时间缩短,但骨髓评估的诊断信心较低。
要点
- 3D-SSFP对盂唇和软骨病变的诊断信心高于2D-TSE-PD fs(4.5±0.8 vs 4.35±0.7,p<0.0001)。
- 3D-SSFP对骨髓病变的诊断信心低于2D-TSE-PD fs(3.9±0.7 vs 4.0±0.7,p<0.0001)。
- 关节镜亚组中3D-SSFP诊断盂唇和软骨病变的特异度高于2D-TSE-PD fs(74.4% vs 42.9%)。
核心结论
- 髋关节MR关节造影中,3D-SSFP检测盂唇和软骨病变的准确度高于2D-TSE-PD fs,同时缩短采集时间;但其骨髓评估的诊断信心较低,因此3D-SSFP应与常规2D-TSE序列联合使用。
研究设计与样本
- 回顾性研究,纳入81例疑似盂唇撕裂患者,使用3T扫描仪行髋关节MR关节造影,采集三个平面的2D-TSE-PD fs序列和单一矢状面3D-SSFP序列,由两名盲法放射科医生独立评估,以关节镜为参考标准在39例患者中确定准确度。
关键影像表现/征象
- 基于图像质量,3D-SSFP对盂唇病变的诊断信心评分为4.5±0.8,2D-TSE-PD fs为4.35±0.7,3D-SSFP更高(p<0.0001)。
- 基于图像质量,3D-SSFP对软骨病变的诊断信心评分为4.5±0.8,2D-TSE-PD fs为4.35±0.7,3D-SSFP更高(p<0.0001)。
- 基于图像质量,3D-SSFP对骨髓病变的诊断信心评分为3.9±0.7,2D-TSE-PD fs为4.0±0.7,3D-SSFP较低(p<0.0001)。
诊断标准与关键数值
- 在39例关节镜患者中,3D-SSFP检测盂唇和软骨病变的敏感度为85.9%,与2D-TSE-PD fs相似。
- 在39例关节镜患者中,3D-SSFP检测盂唇和软骨病变的特异度为74.4%,2D-TSE-PD fs为42.9%,3D-SSFP更高。
- 在39例关节镜患者中,3D-SSFP检测盂唇和软骨病变的阳性和阴性预测值均高于2D-TSE-PD fs。
- 诊断信心采用5点Likert量表评估。
临床应用与阅片要点
- 3D-SSFP可提高髋关节MR关节造影中盂唇和软骨病变的检出准确度并缩短采集时间。
- 由于3D-SSFP对骨髓评估的诊断信心较低,应将其与常规2D-TSE序列联合使用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To retrospectively compare the diagnostic performance of isotropic 3D steady-state free precession (3D-SSFP) sequences with 2D turbo spin-echo proton density-weighted fat-saturated (2D-TSE-PD fs) images in hip magnetic resonance arthrography; arthroscopy was a standard of reference.
METHODS: Eighty-one patients with suspected labral tears who underwent hip MR arthrography (3-T scanner) were included. 2D-TSE-PD fs sequences were acquired in three planes and a singular sagittal 3D-SSFP. Labral tears, cartilage pathology and bone marrow were independently assessed by two blinded radiologists using a 5-point Likert scale. Accuracy was determined in 39 patients using invasive arthroscopy.
RESULTS: Diagnostic confidence of labral and cartilaginous pathologies based on image quality was rated higher for 3D-SSFP (4.5 ± 0.8; 4.35 ± 0.7; p < 0.0001), but inferior for bone marrow pathology (3.9 ± 0.7; 4.0 ± 0.7; p < 0.0001). In the arthroscopy patients, similar sensitivity (85.9%) but higher specificity (74.4vs.42.9%) and higher positive and negative predictive values were found in 3D-SSFP of labral and cartilage pathologies.
CONCLUSIONS: 3D-SSFP in hip magnetic resonance arthrography offers increased accuracy in detecting labral and cartilage pathologies compared with 2D-TSE-PD, while reducing the acquisition time. A drawback of 3D-SSFP was the inferior diagnostic confidence for bone marrow evaluation; thus, 3D-SSFP should be combined with conventional 2D-TSE sequences.
引用
- Kraus MS, Notohamiprodjo M, Partovi S, et al. MR arthrography of the hip: diagnostic performance and image quality of 3D-steady state free precession versus 2D turbo spin echo sequences. Skeletal Radiol. 2018. PMID: 29330619. doi:10.1007/s00256-017-2865-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。