儿童膝关节同时多层加速涡轮自旋回波MRI
回顾性比较儿童膝关节3-T MRI中同时多层(SMS)加速T2加权涡轮自旋回波(TSE)序列与常规TSE序列,74例受试者,SMS对全部15个结构保持诊断质量(平均AUC 0.95/0.97),常规序列在5项质量指标中4项更优(p<0.001),SMS信噪比与对比噪声比低于常规序列,但诊断性能无妥协。
要点
- SMS加速T2w TSE对15个膝关节结构均保持诊断质量,平均AUC达0.95和0.97。
- 常规序列在5项质量指标中4项优于SMS(p<0.001),SMS的SNR和CNR较低。
- 四倍SMS加速可为难以长时间保持静止的儿童患者提供更快的替代方案。
核心结论
- SMS加速T2w TSE序列为儿童膝关节成像提供更快的替代方案,虽SNR降低但诊断性能无妥协,四倍加速对难以长时间保持静止的儿童有益。
研究设计与样本
- 回顾性IRB批准研究,74例受试者(26男,48女,平均年龄15.3岁,范围8-20岁)行3-T膝关节MRI,采用四倍PAT和SMS加速的T2w TSE原型序列及标准仅PAT加速序列;两名读者对15个影像表现和5项质量指标评分,并测量SNR和CNR。
诊断标准与关键数值
- SMS检查对全部15个结构达成共识诊断质量;读者1和读者2的平均AUC分别为0.95和0.97。
- 5项质量指标中4项常规序列优于SMS(p<0.001)。
- 常规序列的SNR和CNR高于SMS序列。
临床应用与阅片要点
- SMS加速T2w TSE可用于儿童膝关节MRI以缩短扫描时间,尤其适用于难以长时间保持静止的患儿。
- 阅片时需注意SMS序列SNR和CNR低于常规序列,但诊断质量对15个结构均无妥协。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare knee MRI performed with the integrated parallel acquisition technique (PAT) and simultaneous multislice (SMS) turbo spin echo (TSE) T2-weighted (T2w) sequences with conventional TSE sequences in pediatric patients.
MATERIALS AND METHODS: This was a retrospective IRB-approved study. Seventy-four subjects (26 male, 48 female, mean age 15.3 years, range 8-20) underwent 3-T MRI of the knee with a T2w TSE pulse sequence prototype with four-fold PAT and SMS acceleration as well as the standard PAT-only accelerated sequences. Images were anonymized and two study folders were created: one examination with only T2w PAT2 images (conventional examination) and one examination with only T2w SMS2/PAT2 sequences (SMS examination). Two readers rated examinations for 15 specific imaging findings and 5 quality metrics. Interreader agreement was measured. Signal to noise (SNR) and contrast to noise (CNR) were measured for SMS and conventional T2w sequences.
RESULTS: Consensus review demonstrated diagnostic quality performance of SMS examinations with respect to all 15 structures. Average area under the curve (AROC) was 0.95 and 0.97 for readers 1 and 2, respectively. The conventional sequence was favored over SMS for four out of five quality metrics (p < 0.001). SNR and CNR were higher for the conventional sequences compared to SMS.
CONCLUSION: SMS accelerated T2w TSE sequences offer a faster alternative for knee imaging in pediatric patients without compromise in diagnostic performance despite diminished SNR. The four-fold acceleration of SMS is beneficial to pediatric patients who often have difficulty staying still for long MRI examinations.
引用
- Benali S, Johnston PR, Gholipour A, et al. Simultaneous multi-slice accelerated turbo spin echo of the knee in pediatric patients. Skeletal Radiol. 2018. PMID: 29332200. doi:10.1007/s00256-017-2868-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。