质子密度脂肪分数(PDFF)MRI用于鉴别良性与恶性椎体病变
该前瞻性研究纳入66例患者,采用3.0T六回波改良Dixon序列测量椎体病变的质子密度脂肪分数(PDFF),以6.40%为阈值区分恶性(<6.40%)与良性(≥6.40%)病变;共77个良性、44个恶性病变,恶性病变PDFF显著低于良性病变及正常椎体骨髓(p<0.001),鉴别良恶性AUC为0.97,鉴别急性椎体骨折与恶性病变AUC为0.95,诊断准确率96%。
要点
- PDFF阈值6.40%可区分恶性(<6.40%)与良性(≥6.40%)椎体病变,诊断准确率96%。
- 恶性椎体病变PDFF显著低于良性病变及正常椎体骨髓(p<0.001)。
- PDFF鉴别良恶性AUC 0.97,鉴别急性椎体骨折与恶性病变AUC 0.95。
核心结论
- 基于六回波改良Dixon序列的PDFF可高诊断准确率地鉴别良性与恶性椎体病变。
研究设计与样本
- 前瞻性研究,纳入66例患者,行3.0T常规MRI(至少矢状位T2加权/频谱衰减反转恢复及T1加权序列)及脊柱矢状位六回波改良Dixon序列,以感兴趣区计算平均PDFF。
关键影像表现/征象
- 恶性椎体病变PDFF显著低于良性病变(p<0.001)。
- 恶性椎体病变PDFF显著低于正常椎体骨髓(p<0.001)。
诊断标准与关键数值
- PDFF阈值6.40%由受试者工作特征曲线确定,用于区分恶性(<6.40%)与良性(≥6.40%)椎体病变。
- 鉴别良性与恶性病变的AUC为0.97(p<0.001)。
- 鉴别急性椎体骨折与恶性病变的AUC为0.95(p<0.001)。
- 鉴别良性病变及急性椎体骨折与恶性肿瘤的诊断准确率为96%。
临床应用与阅片要点
- PDFF测量可用于鉴别常规MRI上信号改变相似、性质待定的椎体病变,帮助避免可能有害的骨活检。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate whether proton density fat fraction (PDFF) measurements using a six-echo modified Dixon sequence can help to differentiate between benign and malignant vertebral bone marrow lesions.
METHODS: Sixty-six patients were prospectively enrolled in our study. In addition to conventional MRI at 3.0-Tesla including at least sagittal T2-weighted/spectral attenuated inversion recovery and T1-weighted sequences, all patients underwent a sagittal six-echo modified Dixon sequence of the spine. The mean PDFF was calculated using regions of interest and compared between vertebral lesions. A cut-off value of 6.40% in PDFF was determined by receiver operating characteristic curves and used to differentiate between malignant (< 6.40%) and benign (≥ 6.40%) vertebral lesions.
RESULTS: There were 77 benign and 44 malignant lesions. The PDFF of malignant lesions was statistically significant lower in comparison with benign lesions (p < 0.001) and normal vertebral bone marrow (p < 0.001). The areas under the curves (AUC) were 0.97 for differentiating benign from malignant lesions (p < 0.001) and 0.95 for differentiating acute vertebral fractures from malignant lesions (p < 0.001). This yielded a diagnostic accuracy of 96% in the differentiation of both benign lesions and acute vertebral fractures from malignancy.
CONCLUSION: PDFF derived from six-echo modified Dixon allows for differentiation between benign and malignant vertebral lesions with a high diagnostic accuracy.
KEY POINTS: • Establishing a diagnosis of indeterminate vertebral lesions is a common clinical problem • Benign bone marrow processes may mimic the signal alterations observed in malignancy • PDFF differentiates between benign and malignant lesions with a high diagnostic accuracy • PDFF of non-neoplastic vertebral lesions is significantly higher than that of malignancy • PDFF from six-echo modified Dixon may help avoid potentially harmful bone biopsy.
引用
- Schmeel FC, Luetkens JA, Wagenhäuser PJ, et al. Proton density fat fraction (PDFF) MRI for differentiation of benign and malignant vertebral lesions. Eur Radiol. 2018. PMID: 29313118. doi:10.1007/s00330-017-5241-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。