文献速递乳腺MR

BI-RADS第5版乳腺MRI分级系统:乳腺肿块描述词与恶性概率的多变量研究

Grading System to Categorize Breast MRI in BI-RADS 5th Edition: A Multivariate Study of Breast Mass Descriptors in Terms of Probability of Malignancy.
PubMed 文献 · AJR Am J Roentgenol · 2018-01-30

本研究分析519个乳腺肿块在BI-RADS第5版中的描述词与恶性概率的关联,采用3点评分和分类系统进行分级,并评估ADC值对第3、4A、4B类病变的附加价值。多变量分析显示形态不规则、边缘非 circumscribed、内部强化(环形和不均匀)及延迟期流出为显著预测因子,纳入ADC值可提高第3、4A、4B类的阳性预测值。

要点

  • 形态不规则、边缘非 circumscribed、环形或不均匀强化、延迟期流出为恶性显著预测因子。
  • 3点评分系统及0至>4分的分类系统与恶性显著相关(p<0.01)。
  • ADC值可提高第3、4A、4B类的阳性预测值,并可能用于下调良性病变分类。

核心结论

  • 3点评分系统及提出的乳腺肿块描述词分类系统可作为有效的分类体系;ADC值可能用于下调第3、4A、4B类中的良性病变。

研究设计与样本

  • 多变量研究,共纳入499例患者的519个乳腺肿块,采用1.5-T MRI扫描仪和16通道专用乳腺射频线圈,由两名放射科医师评估形态学和动力学特征,以活检或手术病理为参考标准。

关键影像表现/征象

  • 形态不规则(p<0.001)、边缘非 circumscribed(p<0.001)、内部强化为环形或均匀(p=0.0001)、延迟期流出(p=0.0003)为恶性显著解释变量。

诊断标准与关键数值

  • 3点评分系统用于恶性可疑征象,分类系统点数范围为0至>4分,两者与恶性显著相关(p<0.01)。
  • 纳入ADC值提高了第3、4A、4B类的阳性预测值。
  • 最优ADC阈值通过最大化Youden指数选择。

临床应用与阅片要点

  • 在BI-RADS第5版乳腺MRI报告中,可参考形态、边缘、内部强化和延迟期流出等描述词评估恶性概率。
  • ADC值可能有助于下调第3、4A、4B类中的良性病变。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study is to analyze the association between the probability of malignancy and breast mass descriptors in the BI-RADS 5th edition and to devise criteria for grading mass lesions, including subcategorization of category 4 lesions with or without apparent diffusion coefficient (ADC) values.

MATERIALS AND METHODS: A total of 519 breast masses in 499 patients were selected. Breast MRI was performed with a 1.5-T MRI scanner using a 16-channel dedicated breast radiofrequency coil. Two radiologists determined the morphologic and kinetic features of the breast masses. Mean ADC values were measured on ADC maps by placing round ROIs that encircled the largest possible solid mass portions. An optimal ADC threshold was chosen to maximize the Youden index. Corresponding pathologic diagnoses were obtained by either biopsy or surgery.

RESULTS: A total of 472 masses were malignant. Multivariate model analysis showed that shape (irregular, p < 0.001), margin type (not circumscribed, p < 0.001), internal enhancement (rim enhancement and heterogeneous enhancement, p = 0.0001), and delayed phase (washout, p = 0.0003) were the significant explanatory variables. The 3-point scoring system for findings suspicious for malignancy and the proposed classification system for breast mass descriptors (with points for category designation ranging from 0 to > 4) were significant with respect to malignancy (p < 0.01). The inclusion of ADC values improved the positive predictive values for categories 3, 4A, and 4B.

CONCLUSION: The 3-point scoring system for findings suspicious for malignancy and the proposed classification system for breast mass descriptors would be valid as a categorization system. ADC values may be used to downgrade benign lesions in categories 3, 4A, and 4B.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Fujiwara K, Yamada T, Kanemaki Y, et al. Grading System to Categorize Breast MRI in BI-RADS 5th Edition: A Multivariate Study of Breast Mass Descriptors in Terms of Probability of Malignancy. AJR Am J Roentgenol. 2018. PMID: 29381382. doi:10.2214/AJR.17.17926

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。