文献速递乳腺乳腺X线

三维立体数字乳腺摄影与二维数字乳腺摄影诊断乳腺病灶的临床性能指标比较:观察者研究

Clinical performance metrics of 3D stereoscopic digital mammography compared with 2D digital mammography: observer study.
PubMed 文献 · Br J Radiol · 2018-03-02

本研究采用JAFROC观察者研究,比较8名放射科医生在40对标准剂量2DDM与3DsDM图像上诊断乳腺病灶的效能,以2名乳腺放射科医生确定的18个BI-RADS≥3的可操作病灶为参考标准。3DsDM的平均品质因子从0.859升至0.936,平均敏感度从74.3%升至92.4%,阅读时间无显著差异。结论认为3DsDM可改善乳腺病灶检测的观察者效能且不显著延长阅读时间。

要点

  • 3DsDM的平均品质因子从0.859升至0.936,差异有统计学意义。
  • 3DsDM平均敏感度从74.3%升至92.4%,假阳性率每例0.2。
  • 3DsDM与2DDM每例平均阅读时间无显著差异。

核心结论

  • 使用3DsDM可改善放射科医生对乳腺病灶的观察者效能,且不显著延长阅读时间。

研究设计与样本

  • 观察者研究,共40对标准剂量2DDM及3DsDM图像,参考标准为2名乳腺放射科医生确定的18个BI-RADS≥3的可操作乳腺病灶,8名放射科医生参与JAFROC分析。

诊断标准与关键数值

  • 以2DDM为对照,3DsDM平均品质因子0.936 vs 2DDM 0.859,p<0.001;在每例假阳性率0.2条件下,3DsDM平均敏感度92.4% vs 2DDM 74.3%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the clinical performance of three-dimensional stereoscopic digital mammography (3DsDM) compared with two-dimensional digital mammography (2DDM) for breast lesion diagnosis with jackknife free-response receiver operating characteristics (JAFROC) observer study.

METHODS: 40 pairs of standard-dose 2DDM and their 3DsDM images were used for an observer performance study. A total of 18 lesions were identified as the reference standard of actionable breast lesions (Breast Imaging Reporting and Data System Category 3 or more) by two breast radiologists. Ratings and locations of "lesions" determined by observers were utilized for assessing the statistical significance of differences between eight radiologists' performances with the 2DDM images and with the 3DsDM images in jackknife free-response receiver operating characteristic analysis.

RESULTS: The average figure-of-merit values for all radiologists increased to a statistically significant degree, from 0.859 with the 2DDM images to 0.936 with the 3DsDM images (p < 0.001). The average sensitivity for detecting actionable lesions was improved from 74.3 to 92.4% at a false-positive rate of 0.2 per case by use of the 3DsDM images. The mean reading time per case with 2DDM images was not significantly different from that with 3DsDM images.

CONCLUSION: The use of 3DsDM would improve the observer performance for breast lesion without considerably extending the reading time. Advances in knowledge: Use of 3DsDM improves radiologists' performance for breast lesion detection.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Daidoji A, Aoki T, Murakami S, et al. Clinical performance metrics of 3D stereoscopic digital mammography compared with 2D digital mammography: observer study. Br J Radiol. 2018. PMID: 29319344. doi:10.1259/bjr.20170908

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。