动态对比增强MRI半定量分析与ADC图直方图分析联合鉴别乳腺良恶性肿块
本研究纳入178例乳腺肿块患者(良性:恶性=88:9),比较DCE-MRI半定量参数与ADC图直方图参数鉴别良恶性的效能。ADC10诊断恶性表现最佳(阈值1.051,ROC 0.885,敏感度86.7%,特异度84.1%);ADC10联合SIslope的AUC为0.888,敏感度82.2%,特异度95.5%,显著优于单用SIslope(p<0.001),但与单用ADC10差异无统计学意义(p=0.914)。
要点
- ADC10鉴别乳腺恶性肿块阈值1.051,ROC 0.885,敏感度86.7%,特异度84.1%。
- SIslope鉴别恶性阈值0.096,ROC 0.756,敏感度86.7%,特异度61.4%。
- ADC10联合SIslope的AUC 0.888,特异度95.5%,显著优于单用SIslope(p<0.001)。
核心结论
- SIslope和ADC10是乳腺恶性肿块的显著预测因子,DCE-MRI与DWI联合可提高鉴别效能。
研究设计与样本
- 本研究纳入178例乳腺肿块患者(良性:恶性=88:9),均行DCE-MRI和DWI检查,比较半定量参数与ADC图直方图参数在良恶性组间的差异。
诊断标准与关键数值
- SIslope预测恶性的截断值为0.096,ROC曲线下面积0.756,敏感度86.7%,特异度61.4%。
- ADC10预测恶性的截断值为1.051,ROC曲线下面积0.885,敏感度86.7%,特异度84.1%。
- ADC10联合SIslope的AUC为0.888,敏感度82.2%,特异度95.5%,显著优于单用SIslope(p<0.001)。
- ADC10联合SIslope的AUC(0.888)高于单用ADC10(0.885),但差异无统计学意义(p=0.914)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate the performance of combined semi-quantitative analysis on dynamic contrast enhanced (DCE) magnetic resonance imaging (MRI) and histogram analysis of diffusion-weighted imaging (DWI) for distinguishing malignant from benign breast masses.
MATERIALS AND METHODS: This study included 178 patients with breast masses (benign:malignant=88:9) who underwent both DCE-MRI and DWI. The semi-quantitative parameters, derived from DCE-MRI, included maximum slope of increase (MSI), signal intensity slope (SIslope), initial percentage of enhancement (Einitial), percentage of peak enhancement (Epeak), early signal enhancement ratio (ESER), and second enhancement percentage (SEP). Histogram parameters derived from apparent diffusion coefficient (ADC) maps included ADCmin, ADCmax, ADCmean, ADC10, ADC25, ADC50, ADC75, ADC90, skewness, and kurtosis. All parameters were compared between malignant and benign groups, and their differences were tested using independent-samples t-test or Mann-Whitney test. Receiver operating characteristic (ROC) curves were used to determine the diagnostic value of each significant parameter.
RESULTS: Among semi-quantitative parameters, SIslope exhibited the best diagnostic performance in predicting malignancy (cut-off value, 0.096; ROC, 0.756; sensitivity, 86.7%; specificity, 61.4%). Among histogram parameters, ADC10 exhibited the best diagnostic performance in predicting malignancy (cut-off value, 1.051; ROC, 0.885; sensitivity, 86.7%; specificity, 84.1%). The optimal diagnostic performance of combined ADC10 and SIslope (area under curve [AUC], 0.888; sensitivity, 82.2%; specificity, 95.5%) was significantly better than SIslope alone (p<0.001). Moreover, the combination showed higher AUC (0.888 versus 0.885) than ADC10 alone, but the difference was not statistically significant (p=0.914).
CONCLUSION: SIslope and ADC10 are significant predictors for breast malignancy. The combination of DCE-MRI and DWI improves differentiating performance.
引用
- Liu HL, Zong M, Wei H, et al. Differentiation between malignant and benign breast masses: combination of semi-quantitative analysis on DCE-MRI and histogram analysis of ADC maps. Clin Radiol. 2017. PMID: 29295753. doi:10.1016/j.crad.2017.11.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。