浸润性导管癌的弥散加权成像ADC值与组织病理学预后因素之间是否存在关联
本研究评估了61例女性浸润性导管癌患者的ADC值与组织病理学预后因素的关系,发现ADC与Ki-67值呈弱负相关(r=-0.279;p=0.029),但与肿瘤分级、Ki-67阳性、雌激素受体阳性、孕激素受体阳性、C-erb B2、淋巴血管侵犯及导管原位癌或小叶原位癌成分均无显著差异;平均ADC值随肿瘤分级升高而降低,但无统计学意义。
要点
- ADC与Ki-67值呈弱负相关(r=-0.279;p=0.029)。
- ADC与肿瘤分级、受体状态等预后因素无显著差异。
- 平均ADC值随肿瘤分级升高而降低,但无统计学意义。
核心结论
- ADC值与Ki-67值呈弱负相关(r=-0.279;p=0.029),但与肿瘤分级、Ki-67阳性、雌激素受体阳性、孕激素受体阳性、C-erb B2、淋巴血管侵犯及导管原位癌或小叶原位癌成分无显著差异;平均ADC值随肿瘤分级升高而降低,但无统计学意义。
研究设计与样本
- 研究纳入61例女性浸润性导管癌患者,行DWI并计算ADC值,b值为500,ROI面积49至100 mm²,由设备自动计算;获取组织样本评估预后因素,采用单因素方差分析、Kruskal Wallis检验、Dunn检验和卡方检验进行统计分析。
局限性
- 文献中存在报道结果相互矛盾的研究,可能由b值、ROI面积和磁场强度的差异引起。
- 作者提出多中心研究和系统综述可能为DWI在乳腺癌中的应用提供关键数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: MRI is being used increasingly as a modality that can provide important information about breast cancer. Diffusion-weighted imaging (DWI) is an imaging technique from which apparent diffusion coefficient (ADC) values can be calculated in addition to obtaining important structural information which cannot be obtained from other imaging studies. We did not find any significant relationships between ADC values and prognostic factors, but did provide some explanations for conflicting results in the literature.
METHODS: The ADC results of 61 females with invasive ductal carcinomas were evaluated. DWI was performed and ADC values were calculated from the area in which restriction of diffusion was the highest in ADC mapping. B value was 500 and region of interest (ROI) was designated between 49 and 100 mm2. Calculations were performed automatically by the device. Tissue samples were obtained for prognostic factor evaluation. The relationships between ADC and prognostic factors were investigated. Comparisons between groups were made with one-way ANOVA and Kruskal Wallis test. Pairwise comparisons were made with Dunn's test. Analyses of categorical variables were made with Chi-square test.
RESULTS: We found a weak negative correlation between ADC and Ki-67 values (r = -0.279; p = 0.029). When we compared ADC values in regard to tumour type, we found no significant differences for tumour grade, Ki-67 positivity, estrogen receptor positivity, progesterone receptor positivity, C-erb B2, lymphovascular invasion and ductal carcinoma in situ or lobular carcinoma in situ component. On a side note, we found that mean ADC values decreased as tumour grade increased; however, this was not statistically significant.
CONCLUSION: The literature contains studies that report conflicting results which may be caused by differences in B values, ROI area and magnetic field strength. Multicentre studies and systematic reviews of these findings may produce crucial data for the use of DWI in breast cancer. Advances in knowledge: To determine if any significant relationship exists between DWI findings and prognostic factors of breast cancer.
引用
- Aydin H, Guner B, Esen Bostanci I, et al. Is there any relationship between adc values of diffusion-weighted imaging and the histopathological prognostic factors of invasive ductal carcinoma? Br J Radiol. 2018. PMID: 29299933. doi:10.1259/bjr.20170705
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。