文献速递乳腺甲状腺与浅表US

弹性成像在乳腺癌患者腋窝检查中的作用

Role of Elastography in Axillary Examination of Patients With Breast Cancer.
PubMed 文献 · J Ultrasound Med · 2018-01-18

研究分析140枚常规超声可见的腋窝淋巴结,评估弹性成像诊断乳腺癌腋窝淋巴结转移的价值。常规超声敏感度76.92%、特异度87.10%、准确率81.43%;析取联合敏感度84.62%、特异度83.87%、准确率84.29%;合取联合特异度和阳性预测值均为100%但敏感度低。弹性成像可作为常规超声的辅助工具。

要点

  • 弹性成像与常规超声析取联合可将诊断敏感度从76.92%提高至84.62%。
  • 合取联合特异度和阳性预测值均达100%,但敏感度低。
  • 淋巴结内硬区比例≥50%定义为弹性成像阳性。

核心结论

  • 弹性成像与常规超声析取联合可提高腋窝淋巴结诊断敏感度。
  • 合取联合虽敏感度低,但可大幅提高阳性预测值。
  • 弹性成像可作为常规超声术前评估乳腺癌腋窝淋巴结的辅助工具。

研究设计与样本

  • 研究纳入140枚常规超声可见的腋窝淋巴结,全部行弹性成像检查。
  • 采用5项常规超声特征评估淋巴结:长径、纵横比、皮质厚度、淋巴门状态和血流模式。
  • 弹性成像通过视觉估计淋巴结内硬区比例,≥50%定义为阳性。
  • 以组织病理学诊断为参考标准,并采用析取和合取联合方式评估。

关键影像表现/征象

  • 常规超声评估腋窝淋巴结采用长径、纵横比、皮质厚度、淋巴门状态和血流模式5项特征。
  • 弹性成像通过视觉估计淋巴结内硬区所占比例进行判定。

诊断标准与关键数值

  • 常规超声诊断敏感度76.92%、特异度87.10%、准确率81.43%。
  • 析取联合诊断敏感度84.62%、特异度83.87%、准确率84.29%。
  • 合取联合特异度100%、阳性预测值100%,但敏感度低。
  • 弹性成像阳性定义为淋巴结内硬区比例≥50%。

临床应用与阅片要点

  • 弹性成像可与常规超声析取联合用于提高腋窝淋巴结诊断敏感度。
  • 合取联合可用于提高阳性预测值,但需注意其敏感度低。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed at exploring the role of ultrasound (US) elastography in the diagnosis of the axillary lymph node status in patients with breast cancer.

METHODS: We analyzed 140 visible axillary lymph nodes on conventional US imaging. All of them underwent elastography. Five conventional US features were adopted to assess axillary lymph nodes: longitudinal diameter, longitudinal-to-transverse diameter ratio, cortical thickness, status of the hilum, and vascular pattern. As for elastography, the proportion of the hard area within each lymph node was estimated visually. The lymph node was defined as positive on elastography when the proportion was 50% or greater. Meanwhile, disjunctive and conjunctive combinations of US and elastography were adopted to evaluate the lymph nodes. The histopathologic diagnosis was regarded as the reference standard.

RESULTS: The sensitivity, specificity, and accuracy were 76.92%, 87.10%, and 81.43%, respectively, for conventional US and 84.62%, 83.87%, and 84.29% for the disjunctive combination. The conjunctive combination had specificity of 100% and a positive predictive value of 100%, whereas the sensitivity was low.

CONCLUSIONS: Elastography can improve the sensitivity when disjunctively combined with conventional US for diagnosis of the axillary lymph node status. Despite the low sensitivity, the conjunctive combination of US and elastography can improve the positive predictive value on a large scale. Elastography is a useful adjuvant tool in addition to conventional US for the preoperative assessment of axillary lymph nodes in patients with breast cancer.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Chang W, Jia W, Shi J, et al. Role of Elastography in Axillary Examination of Patients With Breast Cancer. J Ultrasound Med. 2018. PMID: 29344976. doi:10.1002/jum.14538

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。