T1加权成像呈高信号区的子宫平滑肌肿瘤:平滑肌肉瘤与平滑肌瘤的鉴别
本研究回顾性分析509例患者共1137个直径超过3cm的子宫平滑肌肿瘤的MRI,评估瘤内T1高信号区(T1 HIA)在平滑肌肉瘤与平滑肌瘤间的差异。T1 HIA见于11/14(78.6%)平滑肌肉瘤和15/1118(1.3%)平滑肌瘤;平滑肌瘤的T1 HIA更均匀、边界更清晰、T2低信号环更常见、占据率更小、信号强度比更高。作者认为这些差异可能有助于鉴别平滑肌肉瘤与平滑肌瘤。
要点
- 子宫平滑肌肉瘤中T1高信号区出现率为78.6%(11/14),平滑肌瘤中仅1.3%(15/1118)。
- 平滑肌瘤的T1高信号区更均匀(53% vs 0%,p<0.01)、边界更清晰(60% vs 9%,p<0.05)。
- 平滑肌瘤T1高信号区内T2低信号环更常见(53% vs 9%,p<0.05),占据率更小、信号强度比更高。
核心结论
- 平滑肌瘤内的T1高信号区较平滑肌肉瘤更均匀、边界更清晰、占据率更小、信号强度更高,这些差异可能有助于鉴别平滑肌肉瘤与平滑肌瘤。
研究设计与样本
- 回顾性研究,509例患者共1137个直径超过3cm的子宫平滑肌肿瘤(14个平滑肌肉瘤、5个恶性潜能未定的平滑肌肿瘤、1118个平滑肌瘤),排除红色变性平滑肌瘤和脂肪平滑肌瘤;评估瘤内T1高信号区。
关键影像表现/征象
- T1高信号区见于11/14(78.6%)平滑肌肉瘤、0/5(0%)恶性潜能未定的平滑肌肿瘤和15/1118(1.3%)平滑肌瘤。
- 平滑肌瘤T1高信号区更均匀(53% vs 0%,p<0.01),平滑肌肉瘤为0%。
- 平滑肌瘤T1高信号区边界更清晰(60% vs 9%,p<0.05)。
- 平滑肌瘤T1高信号区内T2低信号环更常见(53% vs 9%,p<0.05)。
- 平滑肌瘤T1高信号区占据率更小(0.20±0.24 vs 0.42±0.27,p<0.05),信号强度比更高(1.83±0.36 vs 1.38±0.23,p<0.01)。
临床应用与阅片要点
- 作者认为瘤内T1高信号区的均匀性、边界、占据率及信号强度差异可能有助于鉴别平滑肌肉瘤与平滑肌瘤。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Hyperintense area on T1 weighted images (T1 HIA) have been reported as suggestive features of uterine leiomyosarcoma (LMS), but differentiating LMS from leiomyoma (LM) is often difficult. This study aimed to evaluate the differences between uterine LMS and LM demonstrating intratumoral T1 HIA.
METHODS: MRI was performed in 509 patients with 1137 uterine smooth muscle tumours [14 LMSs, 5 smooth muscle tumours of uncertain malignant potential , and 1118 LMs] which exceeded 3 cm in diameter. LM with red degeneration and lipoleiomyoma were excluded from the study. We retrospectively reviewed the images and assessed T1 HIA within tumours. Results T1 HIAs were observed in 11/14 (78.6%) LMSs, 0/5 (0%) smooth muscle tumours of uncertain malignant potential, and 15/1118 (1.3%) LMs. T1 HIAs were more homogenous (53 vs 0%, p < 0.01) and more well-demarcated (60 vs 9%, p < 0.05) in LMs than in LMSs. T2 hypointense rim within T1 HIA (53 vs 9%, p < 0.05) was more frequently observed in LMs than in LMSs. The occupying rate of T1 HIA (0.20 ± 0.24 vs 0.42 ± 0.27, p < 0.05) was smaller in LMs than in LMSs. The signal intensity ratio of T1 HIA (1.83 ± 0.36 vs 1.38 ± 0.23, p < 0.01) was greater in LMs than in LMSs.
CONCLUSION: T1 HIA within LM showed more homogeneity, better demarcation, smaller occupying rate, and higher signal intensity than T1 HIA within LMS. Advances in knowledge: The differences in T1 HIA within tumours may be useful for differentiating between LMS and LM.
引用
- Ando T, Kato H, Furui T, et al. Uterine smooth muscle tumours with hyperintense area on T1 weighted images: differentiation between leiomyosarcomas and leiomyomas. Br J Radiol. 2018. PMID: 29308922. doi:10.1259/bjr.20170767
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。