利用双层光谱探测器CT衍生的虚拟单能图像评估静脉期腹部动脉
本研究纳入50例接受腹部动脉期和静脉期双层光谱探测器CT扫描的患者,以动脉期常规重建为参考标准,比较静脉期40 keV虚拟单能图像与常规重建对腹部动脉的评估价值。结果显示40 keV虚拟单能图像在动脉期和静脉期均显著提高衰减值、信噪比和对比噪声比,但管腔直径显著小于常规重建,狭窄程度评估也显著更高,作者认为其适用于静脉期腹部动脉及狭窄评估,但管腔直径偏小的问题引发对参考标准选择的思考。
要点
- 静脉期40 keV虚拟单能图像可用于腹部动脉评估及狭窄程度判断。
- 40 keV虚拟单能图像管腔直径显著小于常规重建(包括参考标准)。
- 狭窄程度在40 keV虚拟单能图像上显著高于常规重建。
核心结论
- 双层光谱探测器CT静脉期低keV虚拟单能图像适用于腹部动脉评估及后续狭窄评估,但40 keV图像管腔直径持续显著小于相应常规重建(包括参考标准),可能源于管腔与管壁区分改善,并引发对血管光谱CT研究合适参考标准的疑问。
研究设计与样本
- 共纳入50例接受双层光谱探测器CT腹部动脉期和静脉期成像的患者,进行个体内比较;动脉期评估常规重建(CRART)及40 keV虚拟单能图像(MonoEART),静脉期评估常规重建(CRVEN)及70 keV和40 keV虚拟单能图像(MonoEVEN);以动脉期成像作为内部参考标准。
诊断标准与关键数值
- 存在动脉狭窄的10例患者按北美症状性颈动脉内膜切除试验(NASCET)标准评估狭窄程度;40 keV虚拟单能图像在动脉期和静脉期的狭窄程度均显著高于常规重建(p≥0.02);40 keV虚拟单能图像在动脉期和静脉期的管腔直径均显著小于CRART(p<0.001),两种虚拟单能重建之间无显著差异(p≥0.92)。
局限性
- 40 keV虚拟单能图像管腔直径持续显著小于相应常规重建(包括参考标准),可能源于管腔与管壁区分改善。
- 研究结果引发对血管光谱CT成像研究应采用何种合适参考标准的疑问。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the utilization of virtual mono-energetic images (MonoE) at low kiloelectron volt (keV) levels derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans using arterial phase imaging as an internal reference standard.
MATERIALS AND METHODS: A total of 50 patients who received arterial and venous phase imaging of the abdomen on a SDCT system were included in this study. Absolute attenuation, noise, signal- and contrast to noise ratios (SNR; CNR) as well as arterial diameters in defined landmarks were assessed. In arterial phase, conventional reconstructions (CRART) as well as MonoEART at 40keV and in venous phase, conventional reconstructions (CRVEN) as well as MonoEVEN at 70 and 40keV were investigated and intra-individual comparisons were performed. If an artery stenosis (10 patients) was present, the degree of stenosis was assessed according to the system of the North American Symptomatic Carotid Endarterectomy Trial (NASCET).
RESULTS: MonoE 40keV yielded significantly higher attenuation values (in arterial as well as in venous phase) compared to CRART (p<0.001) while noise levels were substantially low. This resulted in markedly superior SNR and CNR in large vessel compared to CRART. Luminal diameters were significantly smaller in MonoE 40keV in both contrast phases compared to CRART (p<0.001), whereas no significant differences were found between both MonoE reconstructions (p≥0.92). The degree of vessel stenosis was significantly higher in MonoE 40keV of both contrast phases compared to CRART (p≥0.02).
CONCLUSION: MonoE at low keV of venous contrast phase scans derived from a novel SDCT are suitable for the assessment of arteries in the abdomen and subsequent stenosis assessment. However, MonoE at 40keV constantly showed significant smaller luminal diameters than the corresponding conventional reconstructions (including the reference standard). This is possibly due to an improved differentiation of the vessel lumen from the wall and raises the question, which imaging technique should be used as an appropriate reference standard for vascular SDCT imaging studies.
引用
- Hickethier T, Byrtus J, Hauger M, et al. Utilization of virtual mono-energetic images (MonoE) derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans. Eur J Radiol. 2017. PMID: 29362148. doi:10.1016/j.ejrad.2017.12.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。