扩散加权MRI用于肝泡型棘球蚴病寄生虫初始存活性评估:与正电子发射断层显像的比较
该回顾性研究纳入8例临床确诊肝泡型棘球蚴病患者共14个病灶,比较DWI与18F-FDG PET/CT评估寄生虫存活性的能力。DWI上病灶周围高信号与PET/CT上FDG摄取增高对应,ADC与SUVmax呈显著负相关(r=-0.67,p<0.001)。DWI似可用于常规初始诊断中视觉判断病灶存活性。
要点
- DWI上病灶周围高信号与PET/CT上FDG摄取增高在分布上对应,提示寄生虫存活。
- 直径3-15 cm病灶表现为病灶周围高信号,直径<2 cm病灶表现为结节状高信号。
- ADC与SUVmax呈显著负相关(r=-0.67,p<0.001)。
核心结论
- DWI能够提供视觉检测肝泡型棘球蚴病病灶存活性的信息,可能有助于该病初始诊断中的常规应用。
研究设计与样本
- 回顾性分析8例临床确诊肝泡型棘球蚴病患者,采用PET/CT与DWI(b值0、800 s/mm²)生成ADC图,由两名放射科医生独立判断病灶活性,按病灶逐一比较两种技术,采用Pearson相关系数进行统计分析。
关键影像表现/征象
- 8个病灶(直径3-15 cm)在DWI上显示病灶周围高信号,在PET/CT上显示FDG摄取增高,主要位于病灶与正常肝实质交界处。
- 5个病灶(直径<2 cm)在DWI上显示结节状高信号,在PET/CT上同一分布区域显示「热点」。
- 1例接受口服药物治疗三年的患者,DWI上病灶周围高信号显著减低,PET/CT上显示无FDG摄取的肝缺损。
诊断标准与关键数值
- 活性判断标准:(+)为明显局灶性或病灶周围FDG摄取增高/高信号强度;(-)为无FDG摄取的肝缺损/无高信号强度。
- ADC与SUVmax呈显著负相关(r=-0.67,p<0.001)。
临床应用与阅片要点
- DWI上病灶周围或结节状高信号可视觉提示肝泡型棘球蚴病病灶存活,与PET/CT上FDG摄取增高区域对应。
- 作者认为DWI可能有助于肝泡型棘球蚴病初始诊断中的常规应用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: More than 70% of hepatic alveolar echinococcosis (HAE) are inoperable. Thus, long-term, or even life-long, pharmacological treatment with benzimidazoles is necessary. For effective treatment, it is of great importance to employ imaging techniques to detect and monitor the non-resectable parasitic viability. Therefore, this study aimed to evaluate diffusion-weighted imaging (DWI) in assessing the viability of HAE in comparison to 18-fluoro-deoxyglucose (18F-FDG) positron emission tomography, combined with computed tomography (PET/CT).
MATERIALS AND METHODS: Positron emission tomography, computed tomography and DWI (b-values: 0, 800 s/mm2) were retrospectively analysed in eight patients with clinically-verified HAE to, generate the apparent diffusion coefficient (ADC) map. The activity of HAE lesions in both techniques were determined independently by two radiologists according to the following standard: (+), marked focally or perilesionally increased FDG uptake/high signal intensity; (-), a hepatic defect without FDG uptake/no high signal intensity. Every lesion's maximum standardized uptake value (SUVmax) on the PET/CT images and mean ADC values on the parametric ADC maps were measured respectively. Results of PET/CT and DWI were compared on a per-lesion-basis. Pearson's correlation coefficient was assessed for statistical analysis.
RESULTS: A total of 14 HAE lesions were detected. Eight lesions (diameter 3-15 cm) showed perilesional hyper-signal intensity on DWI. This was visualised on PET/CT as increased FDG uptake. They mainly existed in the lesion's border with normal liver parenchyma. Five lesions (diameter < 2 cm) were detected as nodular hyperintensity on DWI and a 'hot spot' on PET/CT in the same distribution. One patient, who had received oral drug therapy for three years showed significantly decreased perilesional hyperintensity on the DWI and a hepatic defect without any FDG uptake on PET/CT. Pearson's correlation coefficient indicated a significant inverse correlation of the ADC and the SUVmax (r = -0.67, p < 0.001).
CONCLUSION: Diffusion-weighted imaging is capable of offering information on visually detecting the HAE lesions' viability and may be useful for routine application in the initial diagnosis of HAE.
引用
- Zheng J, Wang J, Zhao J, et al. Diffusion-Weighted MRI for the Initial Viability Evaluation of Parasites in Hepatic Alveolar Echinococcosis: Comparison with Positron Emission Tomography. Korean J Radiol. 2018. PMID: 29353998. doi:10.3348/kjr.2018.19.1.40
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。