脾脏点剪切波弹性成像:在门静脉高压患者中的作用
本研究纳入54例食管胃十二指肠镜检查无或低级别食管胃静脉曲张的肝硬化患者,评估脾脏点剪切波弹性成像的可行性及可重复性,并分析脾硬度、肝硬度等无创参数与食管胃静脉曲张存在的相关性。肝硬度预测食管胃静脉曲张的AUROC最高(0.913),脾硬度最低(0.675),脾硬度在预测低级别食管胃静脉曲张方面并不优于肝硬度。
要点
- 脾硬度测量技术成功率77.78%(42/54),肝硬度为90.74%(49/54)。
- 肝硬度预测食管胃静脉曲张的AUROC为0.913,高于脾硬度的0.675。
- 脾硬度在预测低级别食管胃静脉曲张方面不优于肝硬度,不能作为筛查内镜的有用工具。
核心结论
- 脾硬度测量可行且观察者间一致性高,但其预测低级别食管胃静脉曲张的准确性最低(AUROC=0.675),不优于肝硬度(AUROC=0.913),不能作为肝硬化患者筛查食管胃十二指肠镜诊断过程中的有用工具。
研究设计与样本
- 研究纳入54例食管胃十二指肠镜检查无或低级别食管胃静脉曲张的肝硬化患者,同期行腹部超声、肝血管多普勒超声及肝和脾的点剪切波弹性成像;在42例患者中评估肝硬度、脾硬度、血小板计数和脾长径预测食管胃静脉曲张存在的准确性。
诊断标准与关键数值
- 肝硬度预测食管胃静脉曲张的AUROC为0.913,脾硬度为0.675,血小板计数为0.731,脾长径为0.729;脾硬度测量的观察者间一致性高;肝硬度技术成功率为90.74%(49/54),脾硬度为77.78%(42/54)。
临床应用与阅片要点
- 作者认为脾硬度在预测低级别食管胃静脉曲张方面不优于肝硬度,不能作为肝硬化患者筛查食管胃十二指肠镜诊断过程中的有用工具。
局限性
- 脾硬度测量技术成功率为77.78%(42/54),低于肝硬度的90.74%(49/54)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The goals of the study described here were to evaluate the feasibility and reproducibility of measuring spleen stiffness (SS) using point shear wave elastography in a series of cirrhotic patients and to investigate whether SS, liver stiffness (LS) and other non-invasive parameters are correlated with the presence of esophagogastric varices (EVs). Fifty-four cirrhotic patients with low-grade EVs or without EVs at esophago-gastro-duodenoscopy were enrolled. They underwent abdominal ultrasound and Doppler ultrasound of hepatic vessels simultaneously with p-SWE of the liver and spleen. In 42 patients, the accuracy of LS and SS, as well as of platelet count and spleen longitudinal diameter, in predicting the presence of EVs was evaluated. The technical success was 90.74% for LS (49/54 patients) and 77.78% for SS (42/54 patients). Inter-observer agreement for SS measurement was high. Both LS and SS correlated with esophago-gastro-duodenoscopy: LS had the highest accuracy in predicting the presence of EVs (area under the receiver operating characteristic curve [AUROC] = 0.913); SS had the lowest accuracy (AUROC = 0.675); platelet count and spleen diameter had intermediate accuracy (AUROC = 0.731 and 0.729, respectively). SS did not have an advantage over LS in predicting low-grade EVs and cannot be proposed as a useful tool in the diagnostic process of cirrhotic patients who require screening esophago-gastro-duodenoscopy.
引用
- Lucchina N, Recaldini C, Macchi M, et al. Point Shear Wave Elastography of the Spleen: Its Role in Patients with Portal Hypertension. Ultrasound Med Biol. 2018. PMID: 29352618. doi:10.1016/j.ultrasmedbio.2017.11.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。