磁化传递MR成像评估克罗恩病患者肠道纤维化程度
这项前瞻性研究以手术病理为标准,分析31例克罗恩病患者术前腹部磁化传递(MT)成像、增强成像和扩散加权成像,发现归一化MT率与纤维化评分强相关(r=0.769),区分中重度纤维化与无/轻度纤维化的AUC为0.919,优于ADC(0.747)和强化增益百分比(0.592)。验证组5例中MT诊断中重度纤维化的敏感度80%、特异度100%、AUC 0.9。
要点
- 归一化MT率与纤维化评分强相关(r=0.769,P=.000),与炎症评分不相关(r=-0.034,P=.740)。
- 区分中重度纤维化与无/轻度纤维化,MT的AUC为0.919,高于ADC的0.747和强化增益百分比的0.592。
- MT成像可能用于鉴别克罗恩病肠道纤维性与炎性狭窄。
核心结论
- MT成像在检测和区分伴或不伴炎症的肠道纤维化程度方面优于ADC和增强成像,可能用于鉴别克罗恩病患者的纤维性与炎性肠道狭窄。
研究设计与样本
- 前瞻性研究,31例连续克罗恩病患者术前接受腹部MT成像、增强成像和扩散加权成像,以手术组织病理学为参考标准进行逐区对照,并在5例新患者中验证MT成像性能。
关键影像表现/征象
- 归一化MT率在无纤维化、轻度、中度和重度纤维化肠壁间差异有统计学意义(F=49.002,P=.000)。
- 混合纤维化与炎症肠壁的归一化MT率显著高于仅存在炎症的肠壁(t=-8.52,P=.000)。
诊断标准与关键数值
- 归一化MT率区分中重度纤维化与无/轻度纤维化肠壁的AUC为0.919(P=.000)。
- ADC区分中重度纤维化与无/轻度纤维化肠壁的AUC为0.747(P=.001)。
- 强化增益百分比区分中重度纤维化与无/轻度纤维化肠壁的AUC为0.592(P=.209)。
- 验证组中MT成像诊断中重度纤维化的敏感度为80%(12/15)、特异度为100%(3/3)、AUC为0.9(P=.033)。
临床应用与阅片要点
- 阅片时可计算肠壁归一化至骨骼肌的MT率,用于评估纤维化程度并与炎症鉴别。
- MT成像在区分中重度纤维化方面表现优于ADC和强化增益百分比,后者AUC分别为0.747和0.592。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To evaluate the role of magnetization transfer (MT) magnetic resonance (MR) imaging for the characterization of intestinal fibrosis compared with contrast material-enhanced and diffusion-weighted MR imaging and its capability for differentiating fibrotic from inflammatory strictures in humans with Crohn disease (CD) by using surgical histopathologic analysis as the reference standard. Materials and Methods Institutional review board approval and informed consent were obtained for this prospective study. Abdominal MT imaging, contrast-enhanced imaging, and diffusion-weighted imaging of 31 consecutive patients with CD were analyzed before elective surgery. The bowel wall MT ratio normalized to skeletal muscle, the apparent diffusion coefficient (ADC), and the percentage of enhancement gain were calculated; region-by-region correlations with the surgical specimen were performed to determine the histologic degree of fibrosis and inflammation. The performance of MT imaging was validated in five new patients. One-way analysis of variance test, Spearman rank correlation, and receiver operating characteristic curve were used for statistical analysis. Results Normalized MT ratios strongly correlated with fibrosis scores (r = 0.769; P = .000) but did not correlate with inflammation scores (r = -0.034; P = .740). Significant differences (F = 49.002; P = .000) in normalized MT ratios were found among nonfibrotic, mildly, moderately, and severely fibrotic walls. The normalized MT ratios of mixed fibrotic and inflammatory bowel walls were significantly higher than those of bowel walls with only inflammation present (t = -8.52; P = .000). A high accuracy of normalized MT ratios was shown with an area under the receiver operating characteristic curve (AUC) of 0.919 (P = .000) for differentiating moderately to severely fibrotic bowel walls from nonfibrotic and mildly fibrotic bowel walls, followed by ADC (AUC, 0.747; P = .001) and the percentage of enhancement gain (AUC, 0.592; P = .209). The sensitivity, specificity, and AUC of MT imaging for diagnosing moderate to severe fibrosis in the validation data set were 80% (12 of 15), 100% (three of three), and 0.9 (P = .033), respectively. Conclusion MT imaging outperforms ADC and contrast-enhanced imaging in detecting and distinguishing varying degrees of bowel fibrosis with or without coexisting inflammation. MT imaging could potentially be used as a method to differentiate fibrotic from inflammatory intestinal strictures in patients with CD. © RSNA, 2018 Online supplemental material is available for this article.
引用
- Li XH, Mao R, Huang SY, et al. Characterization of Degree of Intestinal Fibrosis in Patients with Crohn Disease by Using Magnetization Transfer MR Imaging. Radiology. 2018. PMID: 29357272. doi:10.1148/radiol.2017171221
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。