文献速递腹部MR

3.0T 磁共振胰胆管成像采用 GRASE 序列:与 3D TSE 相比能否改善图像质量并缩短采集时间

Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: does it improve image quality and acquisition time as compared with 3D TSE?
PubMed 文献 · Eur Radiol · 2018-01-15

本研究纳入 54 例连续接受 MRCP 检查的患者,比较单次屏气梯度自旋回波(GRASE)序列与呼吸导航触发三维涡轮自旋回波(3D TSE)序列的采集时间和图像质量。结果显示 GRASE 的平均采集时间较 3D TSE 缩短 95%(GRASE 20 秒 vs 3D TSE 6 分 27 秒),胆总管与肝脏的对比噪声比显著更高(GRASE 25.4±13.9 vs 3D TSE 18.2±9.6,p<0.01),所有定性评分均显著优于 3D TSE。

要点

  • GRASE 序列平均采集时间 20 秒,较 3D TSE 的 6 分 27 秒缩短 95%。
  • GRASE 的胆总管与肝脏 CNR 为 25.4±13.9,显著高于 3D TSE 的 18.2±9.6(p<0.01)。
  • 两位放射科医生对 GRASE 的整体图像质量、模糊、运动伪影及胆总管显示评分均显著优于 3D TSE。

核心结论

  • 3.0T MRCP 采用单次屏气 GRASE 序列,与常规 3D TSE 的 3D MRCP 相比,显著提高了胆总管 CNR,并将采集时间缩短 95%。

研究设计与样本

  • 研究论文,纳入 54 例连续接受 MRCP 检查的患者,均行 GRASE 与 3D TSE 序列扫描,比较图像采集时间及胆总管与肝脏的 CNR,并由两位放射科医生以 4 分法对整体图像质量、模糊、运动伪影及胆总管显示进行评分,采用配对 t 检验比较变量。

关键影像表现/征象

  • GRASE 序列整体图像质量、模糊、运动伪影及胆总管显示各项定性评分均显著优于 3D TSE。
  • GRASE 的胆总管与肝脏 CNR 显著高于 3D TSE(GRASE 25.4±13.9 vs 3D TSE 18.2±9.6,p<0.01)。

诊断标准与关键数值

  • 图像质量、模糊、运动伪影及胆总管显示采用 4 分法由两位放射科医生评分。
  • CNR 比较对象为胆总管与肝脏,GRASE 25.4±13.9 vs 3D TSE 18.2±9.6,p<0.01。
  • 平均图像采集时间 GRASE 20 秒 vs 3D TSE 6 分 27 秒,GRASE 缩短 95%。

临床应用与阅片要点

  • 原文结论认为,与常规 3D TSE 的 3D MRCP 相比,3.0T MRCP 采用单次屏气 GRASE 序列可显著提高胆总管 CNR 并缩短采集时间。
  • 原文未据此给出具体的临床操作推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The current study evaluated the clinical usefulness of the gradient and spin-echo (GRASE) sequence with single breath-hold in 3.0 T magnetic resonance cholangiopancreatography (MRCP). We compared the acquisition time and image quality between GRASE and breath navigator-triggered 3D turbo spin echo (3D TSE).

METHODS: We examined 54 consecutive patients who underwent MRCP with GRASE and 3D TSE. We compared the image acquisition time and contrast-to-noise ratio (CNR) between the common bile duct (CBD) and liver. Overall image quality, blurring, motion artifacts and CBD visibility were scored on a 4-point scale by two radiologists. Paired t-tests were used to compare the variables.

RESULTS: The mean image acquisition time was 95 % shorter with the GRASE than with 3D TSE (GRASE: 20 s; 3D TSE: 6 min 27 s). The CNR of GRASE was significantly higher than that of 3D TSE (GRASE: 25.4 ± 13.9 vs. 3D TSE: 18.2 ± 9.6, p < 0.01). All qualitative scores for GRASE were significantly better than those for 3D TSE.

CONCLUSIONS: 3.0 T MRCP with GRASE sequence with single breath-hold significantly improved the CNR of CBD with a 95 % shorter acquisition time compared with conventional 3D MRCP with 3D TSE.

KEY POINTS: • MRCP acquisition time was 95% shorter with GRASE than with 3D TSE. • Overall image quality of GRASE was significantly better than 3D TSE. • Pancreaticobiliary tree visibility with GRASE was better than that with 3D TSE.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Yoshida M, Nakaura T, Inoue T, et al. Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: does it improve image quality and acquisition time as compared with 3D TSE? Eur Radiol. 2018. PMID: 29335869. doi:10.1007/s00330-017-5240-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。