文献速递腹部介入技术与安全US

气泡诱导彩色多普勒反馈与组织碎化术所致肝组织结构成分破坏相关

Bubble-Induced Color Doppler Feedback Correlates with Histotripsy-Induced Destruction of Structural Components in Liver Tissue.
PubMed 文献 · Ultrasound Med Biol · 2018-01-09

本研究在离体牛肝组织中使用500 kHz、112阵元相控组织碎化阵列,以每点30–1000个脉冲扫描超过219个位置制造约6×6×7 mm病灶,并用L7-4探头采集气泡诱导彩色多普勒(BCD)信号。BCD的达峰回弹速度时间(tprv)与网状纤维染色III型胶原面积变化的Pearson相关系数为-0.94(p<0.001),提示BCD变化更可能源于组织结构成分的破坏。

要点

  • BCD的tprv指标与网状纤维染色III型胶原面积变化呈Pearson相关系数-0.94(p<0.001)。
  • BCD信号变化更可能反映组织结构成分的破坏,而非仅细胞存活数量变化。
  • 研究采用500 kHz、112阵元相控阵列,L7-4探头采集BCD信号,每点30–1000个脉冲。

核心结论

  • BCD的tprv指标与网状纤维染色III型胶原面积变化呈Pearson相关系数-0.94(p<0.001),提示BCD变化更可能因组织结构成分破坏所致。

研究设计与样本

  • 离体牛肝组织研究,使用500 kHz、112阵元相控组织碎化阵列以每点30–1000个脉冲扫描超过219个位置制造约6×6×7 mm病灶,128阵元L7-4成像探头采集BCD信号,以组织学分析(活细胞计数、网状纤维染色III型胶原面积、三色染色I型胶原面积)为参考。

关键影像表现/征象

  • BCD信号以达峰回弹速度时间(tprv)指标定量分析。
  • tprv与网状纤维染色III型胶原面积变化呈Pearson相关系数-0.94(p<0.001)。

诊断标准与关键数值

  • tprv与网状纤维染色III型胶原面积变化的Pearson相关系数为-0.94(p<0.001)。
  • tprv与其他组织学指标(活细胞计数、三色染色I型胶原面积)的相关性原文未报告具体数值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Bubble-induced color Doppler (BCD) is a histotripsy-therapy monitoring technique that uses Doppler ultrasound to track the motion of residual cavitation nuclei that persist after the collapse of the histotripsy bubble cloud. In this study, BCD is used to monitor tissue fractionation during histotripsy tissue therapy, and the BCD signal is correlated with the destruction of structural and non-structural components identified histologically to further understand how BCD monitors the extent of treatment. A 500-kHz, 112-element phased histotripsy array is used to generate approximately 6- × 6- × 7-mm lesions within ex vivo bovine liver tissue by scanning more than 219 locations with 30-1000 pulses per location. A 128-element L7-4 imaging probe is used to acquire BCD signals during all treatments. The BCD signal is then quantitatively analyzed using the time-to-peak rebound velocity (tprv) metric. Using the Pearson correlation coefficient, the tprv is compared with histologic analytics of lesions generated by various numbers of pulses using a significance level of 0.001. Histologic analytics in this study include viable cell count, reticulin-stained type III collagen area and trichrome-stained type I collagen area. It is found that the tprv metric has a statistically significant correlation with the change in reticulin-stained type III collagen area with a Pearson correlation coefficient of -0.94 (p <0.001), indicating that changes in BCD are more likely because of destruction of the structural components of tissue.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Macoskey JJ, Zhang X, Hall TL, et al. Bubble-Induced Color Doppler Feedback Correlates with Histotripsy-Induced Destruction of Structural Components in Liver Tissue. Ultrasound Med Biol. 2018. PMID: 29329687. doi:10.1016/j.ultrasmedbio.2017.11.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。