单光子发射计算机断层扫描表现及其与定量冠状动脉造影在左主干冠状动脉显著狭窄患者中的关系
回顾性分析55例经有创冠状动脉造影确诊左主干狭窄≥50%的患者,比较SPECT药物负荷心肌灌注显像与定量冠状动脉造影(QCA)结果。仅4例(7.3%)为孤立性左主干病变,仅3例(5.4%)SPECT呈典型左主干可逆性灌注缺损模式;SPECT表现异质、不特异,与QCA相关性差,可能与其他心外膜冠状动脉显著狭窄高发有关。
要点
- 左主干显著狭窄患者中仅5.4%SPECT呈典型左主干可逆性灌注缺损模式。
- SPECT表现异质且不特异, summed stress score不随左主干狭窄严重程度变化。
- 仅7.3%为孤立性左主干病变,多数合并其他心外膜冠状动脉显著狭窄。
核心结论
- 在左主干显著狭窄患者中,SPECT表现异质、不特异,与QCA数据相关性差,可能与其他心外膜冠状动脉显著狭窄高发有关。
研究设计与样本
- 回顾性研究,纳入55例(男39例,平均年龄68.1±10.9岁)经有创冠状动脉造影诊断左主干狭窄≥50%的患者,均在ICA后30天内行SPECT药物负荷显像,所有冠状动脉病变通过QCA定量,SPECT结果与QCA比较。
关键影像表现/征象
- 仅4例(7.3%)为孤立性左主干病变,其余均合并一支或多支其他心外膜冠状动脉显著狭窄(≥70%)。
- 仅3例(5.4%)SPECT呈典型左主干可逆性灌注缺损模式。
- 冠状动脉病变更严重的患者倾向于在更多区域出现更高的 summed difference score 值,但具体模式未明确定义。
- SPECT的 summed stress score 不随左主干狭窄严重程度而变化。
诊断标准与关键数值
- 左主干显著狭窄定义为有创冠状动脉造影示狭窄≥50%。
- 其他心外膜冠状动脉显著狭窄定义为狭窄≥70%。
- 左前降支供血区狭窄严重程度与负荷灌注百分数呈显著负线性相关(r=-0.455,p<0.001),左回旋支供血区无此相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Unrecognized left main coronary artery disease (LMCD) is often fatal; however, accuracy of non-invasive tests for diagnosing LMCD is still unsatisfactory. This study was performed to elucidate single-photon emission computed tomography (SPECT) detection of LMCD using quantitative coronary angiography (QCA) data.
MATERIALS AND METHODS: Fifty-five patients (39 men; mean age, 68.1 ± 10.9 years) diagnosed with significant left main (LM) stenosis (≥ 50%) by invasive coronary angiography (ICA) were retrospectively reviewed. All study patients underwent SPECT with pharmacologic stress within 30 days of ICA. All coronary lesions were quantified via QCA, and SPECT findings were compared with QCA results.
RESULTS: Only four patients (7.3%) had isolated LMCD; all others had combined significant stenosis (≥ 70%) of one or more other epicardial coronary arteries. Patients with more severe coronary artery disease tended to have higher values for summed difference scores in a greater number of regions, but the specific pattern was not clearly defined. Summed stress score of SPECT did not differ according to LM stenosis severity. Only three patients (5.4%) had a typical LM pattern of reversible perfusion defect on SPECT. A significant negative linear correlation between stenosis severity and stress perfusion percent was found in the left anterior descending artery region (r = -0.455, p < 0.001) but not in the left circumflex artery.
CONCLUSION: Single-photon emission computed tomography findings were heterogeneous, not specific and poorly correlated to QCA data in patients with significant LMCD. This may be due to highly prevalent significant stenosis of other epicardial coronary arteries.
引用
- Kim HL, Oh SW, Lee H, et al. Findings of Single-Photon Emission Computed Tomography and Its Relation with Quantitative Coronary Angiography in Patients with Significant Stenosis of the Left Main Coronary Artery. Korean J Radiol. 2018. PMID: 29354006. doi:10.3348/kjr.2018.19.1.101