文献速递心血管CT

基于定量冠状动脉CT血管成像的机器学习整合预测病变特异性缺血:一项多中心研究

Integrated prediction of lesion-specific ischaemia from quantitative coronary CT angiography using machine learning: a multicentre study.
PubMed 文献 · Eur Radiol · 2018-01-19

多中心研究纳入254例患者、484支血管,用半自动软件定量冠状动脉CTA斑块特征,并以机器学习整合预测有创FFR定义的病变特异性缺血。机器学习模型AUC为0.84,高于狭窄程度0.76、低密度非钙化斑块体积0.77、总斑块体积0.74和CAD验前概率0.63。

要点

  • 机器学习整合缺血风险评分预测病变特异性缺血的AUC为0.84,高于单项CTA定量指标。
  • 对比剂密度差(CDD)的信息增益最高(0.172),其次为低密度非钙化斑块体积(0.125)。
  • 低密度非钙化斑块定义为CT值<30 HU,其体积预测缺血的AUC为0.77。

核心结论

  • 机器学习整合缺血风险评分在预测有创FFR定义的病变特异性缺血方面,优于狭窄程度、斑块定量指标和CAD验前概率。

研究设计与样本

  • 多中心试验纳入254例患者,行冠状动脉CTA和有创冠状动脉造影,对484支血管行FFR测量。
  • CTA数据集用半自动软件定量狭窄、非钙化斑块体积、低密度非钙化斑块体积(<30 HU)、钙化斑块体积、总斑块体积、对比剂密度差(CDD,单位面积管腔衰减最大差值)和斑块长度。
  • 机器学习整合包括自动特征选择和模型构建,采用提升集成算法和十折分层交叉验证。

诊断标准与关键数值

  • 以有创FFR≤0.80定义病变特异性缺血;80例患者共100支血管存在缺血。
  • 机器学习模型预测缺血的AUC为0.84,高于狭窄程度AUC 0.76、低密度非钙化斑块体积AUC 0.77、总斑块体积AUC 0.74和CAD验前概率AUC 0.63,P<0.006。
  • 预测缺血的信息增益以CDD最高(0.172),其次为低密度非钙化斑块体积(0.125)、非钙化斑块体积(0.097)和总斑块体积(0.092)。

临床应用与阅片要点

  • 原文结论认为机器学习整合缺血风险评分改善了病变特异性缺血的预测,优于狭窄程度、斑块定量指标和CAD验前概率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: We aimed to investigate if lesion-specific ischaemia by invasive fractional flow reserve (FFR) can be predicted by an integrated machine learning (ML) ischaemia risk score from quantitative plaque measures from coronary computed tomography angiography (CTA).

METHODS: In a multicentre trial of 254 patients, CTA and invasive coronary angiography were performed, with FFR in 484 vessels. CTA data sets were analysed by semi-automated software to quantify stenosis and non-calcified (NCP), low-density NCP (LD-NCP, < 30 HU), calcified and total plaque volumes, contrast density difference (CDD, maximum difference in luminal attenuation per unit area) and plaque length. ML integration included automated feature selection and model building from quantitative CTA with a boosted ensemble algorithm, and tenfold stratified cross-validation.

RESULTS: Eighty patients had ischaemia by FFR (FFR ≤ 0.80) in 100 vessels. Information gain for predicting ischaemia was highest for CDD (0.172), followed by LD-NCP (0.125), NCP (0.097), and total plaque volumes (0.092). ML exhibited higher area-under-the-curve (0.84) than individual CTA measures, including stenosis (0.76), LD-NCP volume (0.77), total plaque volume (0.74) and pre-test likelihood of coronary artery disease (CAD) (0.63); p < 0.006.

CONCLUSIONS: Integrated ML ischaemia risk score improved the prediction of lesion-specific ischaemia by invasive FFR, over stenosis, plaque measures and pre-test likelihood of CAD.

KEY POINTS: • Integrated ischaemia risk score improved prediction of ischaemia over quantitative plaque measures • Integrated ischaemia risk score showed higher prediction of ischaemia than standard approach • Contrast density difference had the highest information gain to identify lesion-specific ischaemia.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Dey D, Gaur S, Ovrehus KA, et al. Integrated prediction of lesion-specific ischaemia from quantitative coronary CT angiography using machine learning: a multicentre study. Eur Radiol. 2018. PMID: 29352380. doi:10.1007/s00330-017-5223-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。