第三代双源CT可准确诊断所有尺寸支架内的冠状动脉再狭窄,辐射剂量低且图像质量保持

Third generation dual-source CT enables accurate diagnosis of coronary restenosis in all size stents with low radiation dose and preserved image quality.
PubMed 文献 · Eur Radiol · 2018-01-18

本研究前瞻性纳入疑似支架内再狭窄的症状性患者,在1个月内行冠状动脉CT血管成像(CCTA)与有创冠状动脉造影(ICA)对照,以支架内新生内膜增殖致直径狭窄≥50%定义再狭窄;69例患者140枚支架的分析显示,基于患者、病变和支架的诊断准确率分别为95.7%、94.1%和94.3%,小口径支架组(直径<3 mm)准确率88.5%略低于大口径支架组(直径≥3 mm)的98.7%(p=0.01),平均总辐射剂量1.3±0.72 mSv,高螺距采集患者为0.95±0.17 mSv。

要点

  • 第三代双源CT对大口径(≥3 mm)和小口径(<3 mm)支架内再狭窄均可准确诊断。
  • 小口径支架组诊断准确率88.5%,较大口径支架组98.7%略低(p=0.01)。
  • 平均总辐射剂量1.3±0.72 mSv,高螺距采集患者0.95±0.17 mSv,图像质量保持。

核心结论

  • 第三代双源CT能准确诊断大口径和小口径支架的冠状动脉支架内再狭窄,并可实现低辐射剂量且保持图像质量。

研究设计与样本

  • 前瞻性研究,最终纳入69例患者共140枚支架,疑似支架内再狭窄的症状性患者行CCTA与ICA,两者间隔1个月内完成对照。

诊断标准与关键数值

  • 支架内再狭窄定义为支架内新生内膜增殖导致直径狭窄≥50%;基于患者的诊断准确率95.7%,基于病变94.1%,基于支架94.3%;小口径支架组(直径<3 mm)诊断准确率88.5%,大口径支架组(直径≥3 mm)98.7%(p=0.01)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the diagnostic performance of low dose stent imaging in patients with large (≥ 3 mm) and small (< 3 mm) calibre stents by third-generation dual-source CT.

METHODS: Symptomatic patients suspected of having in-stent restenosis (ISR) were prospectively enrolled. Coronary computed tomography angiography (CCTA) and invasive coronary angiography (ICA) were performed within 1 month for correlation. Binary ISR was defined as an in-stent neointimal proliferation with diameter stenosis ≥ 50%. The radiation dose and image quality of CCTA were also assessed.

RESULTS: Sixty-nine patients with 140 stents were ultimately included for analysis. The mean total radiation dose of CCTA was 1.3 ± 0.72 mSv in all patients and 0.95 ± 0.17 mSv in patients with high pitch acquisition. The overall diagnostic accuracy of CCTA stent imaging of patient-based, lesion-based and stent-based analysis was 95.7%, 94.1% and 94.3%, respectively. Further, the diagnostic accuracy of CCTA in the small calibre stent group (diameter < 3 mm) was slightly lower than that of the large calibre stent group (diameter ≥ 3 mm) (88.5% versus 98.7%, p = 0.01).

CONCLUSIONS: Third-generation dual-source CT enables accurate diagnosis of coronary ISR of both large and small calibre stents. Low radiation dose could be achieved with preserved image quality.

KEY POINTS: • Third-generation DSCT enables accurate diagnosis of coronary ISR of all size stents. • Low radiation dose could be achieved with preserved image quality. • The diagnostic accuracy of CCTA of small calibre stents was 88.5%.