冠状动脉疾病报告与数据系统(CAD-RADS):标准化冠状动脉CT血管成像报告相关的预后与临床意义
在CONFIRM国际多中心注册中,5039例无已知冠心病患者接受冠状动脉CTA并按CAD-RADS评分分层。CAD-RADS 0至5的5年无事件生存率从95.2%降至69.3%,评分越高事件风险越高,CAD-RADS对死亡或心肌梗死的预测AUC为0.7052,不劣于Duke CAD指数和传统CAD分类。无严重CAD患者中ICA使用频繁,许多为无症状或未用抗心绞痛药物。
要点
- CAD-RADS评分越高,5年无事件生存率越低(0分95.2%至5分69.3%),事件风险升高。
- CAD-RADS预测死亡或心肌梗死的AUC为0.7052,不劣于Duke指数(0.7073)和传统分类(0.7095)。
- 无严重CAD患者中ICA使用频繁:CAD-RADS 0-2为13%,3为66%,≥4A为84%。
核心结论
- CAD-RADS能有效识别不良事件风险患者,将其纳入冠状动脉CTA报告可能为促进CTA后循证诊疗提供新机会。
研究设计与样本
- CONFIRM国际多中心注册中,5039例无已知冠心病患者接受冠状动脉CTA并按CAD-RADS评分分层,采用Kaplan-Meier和多变量Cox模型估计全因死亡或心肌梗死,用ROC曲线比较CAD-RADS与Duke CAD指数及传统CAD分类。
诊断标准与关键数值
- CAD-RADS评分将CAD狭窄严重程度分为0(0%)、1(1%-24%)、2(25%-49%)、3(50%-69%)、4A(1-2支血管70%-99%)、4B(3支血管70%-99%或左主干≥50%)、5(100%)。
- CAD-RADS 0至5的5年累积无事件生存率从95.2%至69.3%(p<0.0001)。
- 较高评分与事件风险升高相关(HR 2.46至6.09;p<0.0001)。
- CAD-RADS预测死亡或心肌梗死的ROC曲线下面积为0.7052,不劣于Duke指数(0.7073;p=0.893)和传统CAD分类(0.7095;p=0.783)。
临床应用与阅片要点
- ICA转诊率:CAD-RADS 0-2为13%,CAD-RADS 3为66%,CAD-RADS ≥4A为84%。
- CAD-RADS 3患者中,58%的导管插入术发生在随访前30天内。
- 在有药物数据的患者亚组中,接受30天ICA的CAD-RADS 3患者中57%在基线时无症状或未接受抗心绞痛治疗,仅32%有 angina 并接受药物治疗。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study sought to assess clinical outcomes associated with the novel Coronary Artery Disease-Reporting and Data System (CAD-RADS) scores used to standardize coronary computed tomography angiography (CTA) reporting and their potential utility in guiding post-coronary CTA care.
BACKGROUND: Clinical decision support is a major focus of health care policies aimed at improving guideline-directed care. Recently, CAD-RADS was developed to standardize coronary CTA reporting and includes clinical recommendations to facilitate patient management after coronary CTA.
METHODS: In the multinational CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter) registry, 5,039 patients without known coronary artery disease (CAD) underwent coronary CTA and were stratified by CAD-RADS scores, which rank CAD stenosis severity as 0 (0%), 1 (1% to 24%), 2 (25% to 49%), 3 (50% to 69%), 4A (70% to 99% in 1 to 2 vessels), 4B (70% to 99% in 3 vessels or ≥50% left main), or 5 (100%). Kaplan-Meier and multivariable Cox models were used to estimate all-cause mortality or myocardial infarction (MI). Receiver-operating characteristic (ROC) curves were used to compare CAD-RADS to the Duke CAD Index and traditional CAD classification. Referrals to invasive coronary angiography (ICA) after coronary CTA were also assessed.
RESULTS: Cumulative 5-year event-free survival ranged from 95.2% to 69.3% for CAD-RADS 0 to 5 (p < 0.0001). Higher scores were associated with elevations in event risk (hazard ratio: 2.46 to 6.09; p < 0.0001). The ROC curve for prediction of death or MI was 0.7052 for CAD-RADS, which was noninferior to the Duke Index (0.7073; p = 0.893) and traditional CAD classification (0.7095; p = 0.783). ICA rates were 13% for CAD-RADS 0 to 2, 66% for CAD-RADS 3, and 84% for CAD-RADS ≥4A. For CAD-RADS 3, 58% of all catheterizations occurred within the first 30 days of follow-up. In a patient subset with available medication data, 57% of CAD-RADS 3 patients who received 30-day ICA were either asymptomatic or not receiving antianginal therapy at baseline, whereas only 32% had angina and were receiving medical therapy.
CONCLUSIONS: CAD-RADS effectively identified patients at risk for adverse events. Frequent ICA use was observed among patients without severe CAD, many of whom were asymptomatic or not taking antianginal drugs. Incorporating CAD-RADS into coronary CTA reports may provide a novel opportunity to promote evidence-based care post-coronary CTA.
引用
- Xie JX, Cury RC, Leipsic J, et al. The Coronary Artery Disease-Reporting and Data System (CAD-RADS): Prognostic and Clinical Implications Associated With Standardized Coronary Computed Tomography Angiography Reporting. JACC Cardiovasc Imaging. 2018. PMID: 29301713. doi:10.1016/j.jcmg.2017.08.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。