文献速递胸部外周血管介入CTDSA

双输入CT灌注在肺结核大咯血患者支气管-肺动脉瘘检测中的诊断价值

Diagnostic Value of Dual-input Computed Tomography Perfusion on Detecting Bronchial-Pulmonary Artery Fistula in Tuberculosis Patients with Massive Hemoptysis.
PubMed 文献 · Acad Radiol · 2018-01-19

前瞻性纳入2015年1月至12月20例肺结核大咯血患者,以数字减影血管造影为金标准,评估双输入CT灌注参数诊断支气管-肺动脉瘘的效能。与正常血流肺段(n=304)相比,瘘肺段(n=164)肺血流值及灌注指数降低、支气管动脉值升高。灌注指数和支气管动脉ROC曲线下面积均>0.9(P<.001),最佳截断点敏感度和特异度0.79至0.95,灌注指数诊断准确率0.91。

要点

  • 双输入CT灌注可检测肺结核大咯血患者的支气管-肺动脉瘘。
  • 瘘肺段灌注指数降低、支气管动脉值升高,与正常肺段不同。
  • 灌注指数诊断效能最佳,ROC曲线下面积>0.9、准确率0.91。

核心结论

  • 双输入CT灌注对肺结核大咯血患者的支气管-肺动脉瘘具有诊断价值,可作为替代诊断方法。

研究设计与样本

  • 前瞻性研究,纳入2015年1月至2015年12月20例肺结核大咯血患者,以数字减影血管造影为金标准,评估双输入CT灌注参数的诊断效能。

关键影像表现/征象

  • 与正常血流肺段(n=304)相比,支气管-肺动脉瘘肺段(n=164)的肺血流值降低。
  • 与正常血流肺段(n=304)相比,支气管-肺动脉瘘肺段(n=164)的灌注指数值降低。
  • 与正常血流肺段(n=304)相比,支气管-肺动脉瘘肺段(n=164)的支气管动脉值升高。
  • 上述差异经多因素逻辑回归进一步确认。

诊断标准与关键数值

  • 灌注指数和支气管动脉的ROC曲线下面积均>0.9(P<.001)。
  • 最佳截断点下敏感度和特异度为0.79至0.95。
  • 灌注指数诊断效能最佳,总体诊断准确率为0.91。

临床应用与阅片要点

  • 双输入CT灌注参数可辅助识别肺结核大咯血患者的支气管-肺动脉瘘。
  • 灌注指数降低和支气管动脉值升高提示支气管-肺动脉瘘可能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: This prospective study aimed to evaluate the diagnostic performance of dual-input computed tomography perfusion technique (DI-CTP) in identifying the bronchial-pulmonary artery fistula in patients tuberculosis with massive hemoptysis.

MATERIAL AND METHODS: Twenty patients with tuberculosis with massive hemoptysis were enrolled from January 2015 to December 2015. The association between DI-CTP parameters and the diagnostic outcomes of digital subtraction angiography was assessed. Diagnostic efficacy of DI-CTP was evaluated by receiver operating curve (ROC) analyses using the diagnostic outcomes of digital subtraction angiography, which is the gold standard for identifying bronchial-pulmonary artery fistula.

RESULTS: Compared to lung segments with normal blood flow (n = 304), those with bronchial-pulmonary artery fistula (n = 164) had a reduced pulmonary flow value, perfusion index (PI) value, and an elevated bronchial artery (BF) value in the DI-CTP scan, which was further confirmed by multivariate logistic regression. ROC analysis showed that PI and bronchial artery has an excellent diagnostic performance (both area under the ROC curve > 0.9, P < .001) and high sensitivity and specificity (from 0.79 to 0.95 at the optimal cutoff). PI has the best diagnostic performance, with an overall diagnostic accuracy of 0.91.

CONCLUSIONS: DI-CTP scan possesses the diagnostic value for detecting bronchial-pulmonary artery fistula in patients with tuberculosis with massive hemoptysis, providing an alternative diagnostic method.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Qu H, Wang M, Wang Z, et al. Diagnostic Value of Dual-input Computed Tomography Perfusion on Detecting Bronchial-Pulmonary Artery Fistula in Tuberculosis Patients with Massive Hemoptysis. Acad Radiol. 2018. PMID: 29371122. doi:10.1016/j.acra.2017.12.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。