文献速递胸部CT

应用能谱CT评估肺部局灶性磨玻璃影的血供状态

Assessing the Blood Supply Status of the Focal Ground-Glass Opacity in Lungs Using Spectral Computed Tomography.
PubMed 文献 · Korean J Radiol · 2018-01-02

回顾性纳入48例肺腺癌患者共53个磨玻璃影,于治疗前行动脉期双能能谱CT扫描并做物质分解分析。结果示磨玻璃影的碘浓度与水含量均高于同侧及对侧正常肺组织(均P<0.001);纯磨玻璃影与混合磨玻璃影的标准化碘浓度及水含量差异有统计学意义,浸润前病变与微浸润腺癌组和浸润性腺癌组的水含量差异有统计学意义(P<0.001)。作者认为碘浓度可定量反映磨玻璃影的血供状态。

要点

  • 动脉期能谱CT物质分解可定量测量磨玻璃影的碘浓度,作为其血供状态的指标。
  • 磨玻璃影碘浓度与水含量均高于同侧及对侧正常肺组织(均P<0.001)。
  • 纯磨玻璃影与混合磨玻璃影的标准化碘浓度(P=0.049)及水含量(P<0.001)存在统计学差异。

核心结论

  • 利用双能能谱CT及物质分解分析可定量测量磨玻璃影的碘浓度,该指标可作为磨玻璃影血供状态的指标。

研究设计与样本

  • 回顾性研究,纳入48例肺腺癌患者共53个磨玻璃影,均于治疗前接受对比增强双能能谱CT扫描。
  • 在动脉期测量磨玻璃影、同侧及对侧正常肺组织的碘浓度与水含量并分析其差异。
  • 比较纯磨玻璃影与混合磨玻璃影之间、浸润前病变与微浸润腺癌组和浸润性腺癌组之间的碘浓度、标准化碘浓度及水含量。

诊断标准与关键数值

  • 纯磨玻璃影动脉期碘浓度20.9±6.2 mg/mL、水含量345.1±87.1 mg/mL,均高于对侧正常肺组织(碘浓度15.0±4.9 mg/mL、水含量156.4±36.8 mg/mL)及同侧正常肺组织(碘浓度15.1±6.2 mg/mL、水含量156.3±38.8 mg/mL),均P<0.001。
  • 混合磨玻璃影动脉期碘浓度23.8±8.3 mg/mL、水含量606.8±124.5 mg/mL,均高于对侧正常肺组织(碘浓度16.2±5.7 mg/mL、水含量169.4±41.0 mg/mL)及同侧正常肺组织(碘浓度15.9±6.0 mg/mL、水含量174.7±39.2 mg/mL),均P<0.001。
  • 按动脉值标准化后,纯磨玻璃影标准化碘浓度0.1、水含量345.1±87.1 mg/mL,混合磨玻璃影标准化碘浓度0.2、水含量606.8±124.5 mg/mL,两者标准化碘浓度差异P=0.049、水含量差异P<0.001,而碘浓度差异无统计学意义(P=0.161)。
  • 浸润前病变与微浸润腺癌组水含量345.4±96.1 mg/mL,浸润性腺癌组水含量550.1±158.2 mg/mL,两组差异有统计学意义(P<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To exploit material decomposition analysis in dual-energy spectral computed tomography (CT) to assess the blood supply status of the ground-glass opacity (GGO) in lungs.

MATERIALS AND METHODS: This retrospective study included 48 patients with lung adenocarcinoma, who underwent a contrast-enhanced dual-energy spectral CT scan before treatment (53 GGOs in total). The iodine concentration (IC) and water content (WC) of the GGO, the contralateral and ipsilateral normal lung tissues were measured in the arterial phase (AP) and their differences were analyzed. IC, normalized IC (NIC), and WC values were compared between the pure ground-glass opacity (pGGO) and the mixed ground-glass opacity (mGGO), and between the group of preinvasive lesions and the minimally invasive adenocarcinoma (MIA) and invasive adenocarcinoma (IA) groups.

RESULTS: The values of pGGO (IC = 20.9 ± 6.2 mg/mL and WC = 345.1 ± 87.1 mg/mL) and mGGO (IC = 23.8 ± 8.3 mg/mL and WC = 606.8 ± 124.5 mg/mL) in the AP were significantly higher than those of the contralateral normal lung tissues (IC = 15.0 ± 4.9 mg/mL and WC = 156.4 ± 36.8 mg/mL; IC = 16.2 ± 5.7 mg/mL and WC = 169.4 ± 41.0 mg/mL) and ipsilateral normal lung tissues (IC = 15.1 ± 6.2 mg/mL and WC = 156.3 ± 38.8 mg/mL; IC = 15.9 ± 6.0 mg/mL and WC = 174.7 ± 39.2 mg/mL; all p < 0.001). After normalizing the data according to the values of the artery, pGGO (NIC = 0.1 and WC = 345.1 ± 87.1 mg/mL) and mGGO (NIC = 0.2 and WC = 606.8 ± 124.5 mg/mL) were statistically different (p = 0.049 and p < 0.001, respectively), but not for the IC value (p = 0.161). The WC values of the group with preinvasive lesions and MIA (345.4 ± 96.1 mg/mL) and IA (550.1 ± 158.2 mg/mL) were statistically different (p < 0.001).

CONCLUSION: Using dual-energy spectral CT and material decomposition analysis, the IC in GGO can be quantitatively measured which can be an indicator of the blood supply status in the GGO.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Liu G, Li M, Li G, et al. Assessing the Blood Supply Status of the Focal Ground-Glass Opacity in Lungs Using Spectral Computed Tomography. Korean J Radiol. 2018. PMID: 29354009. doi:10.3348/kjr.2018.19.1.130

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。