文献速递胸部CT

期刊俱乐部:计算机辅助检测肺结节在CT上应用计算机化肺血管抑制功能

JOURNAL CLUB: Computer-Aided Detection of Lung Nodules on CT With a Computerized Pulmonary Vessel Suppressed Function.
PubMed 文献 · AJR Am J Roentgenol · 2018-01-16

本研究评估放射科医生在肺血管图像抑制联合计算机辅助检测(VIS/CADe)系统辅助下,于胸部CT检测可操作结节的表现。12名放射科医生对324例(含95例癌症和83例良性结节)进行无辅助与有辅助的对比阅读,结果显示VIS/CADe显著提高肺癌和可操作结节的检测LROC-AUC、癌症检出率并降低特异度,同时阅片时间显著减少26%。

要点

  • VIS/CADe辅助使肺癌检测LROC-AUC从0.633升至0.773(p<0.01)。
  • VIS/CADe辅助使癌症检出率从64.45%升至80.0%(p<0.01),特异度从89.9%降至84.4%(p<0.01)。
  • VIS/CADe辅助使放射科医生阅片时间显著减少26%。

核心结论

  • VIS/CADe系统显著提高放射科医生对癌症和可操作结节的检测,但特异度有所降低;阅片速度提高约四分之一;该技术有潜力辅助检测额外可操作结节。

研究设计与样本

  • 比较研究,12名放射科医生参与,使用324例(含95例癌症和83例良性结节),无结节病例与有结节病例比例为2:1;采用定位ROC(LROC)方法分析。

诊断标准与关键数值

  • VIS/CADe独立测试检测恶性结节敏感度89.5%,检测所有不小于5 mm结节敏感度82.0%,每例CT假阳性率0.58;读者研究中,无辅助 vs 有辅助VIS/CADe:肺癌检测LROC-AUC 0.633 vs 0.773(p<0.01),所有临床可操作结节检测LROC-AUC 0.584 vs 0.692(p<0.01),癌症检出率64.45% vs 80.0%(p<0.01),特异度89.9% vs 84.4%(p<0.01)。

临床应用与阅片要点

  • 作者认为VIS/CADe技术有潜力辅助放射科医生在胸部CT上检测额外可操作结节。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study is to evaluate radiologists' performance in detecting actionable nodules on chest CT when aided by a pulmonary vessel image-suppressed function and a computer-aided detection (CADe) system.

MATERIALS AND METHODS: A novel computerized pulmonary vessel image-suppressed function with a built-in CADe (VIS/CADe) system was developed to assist radiologists in interpreting thoracic CT images. Twelve radiologists participated in a comparative study without and with the VIS/CADe using 324 cases (involving 95 cancers and 83 benign nodules). The ratio of nodule-free cases to cases with nodules was 2:1 in the study. Localization ROC (LROC) methods were used for analysis.

RESULTS: In a stand-alone test, the VIS/CADe system detected 89.5% and 82.0% of malignant nodules and all nodules no smaller than 5 mm, respectively. The false-positive rate per CT study was 0.58. For the reader study, the mean area under the LROC curve (LROCAUC) for the detection of lung cancer significantly increased from 0.633 when unaided by VIS/CADe to 0.773 when aided by VIS/CADe (p < 0.01). For the detection of all clinically actionable nodules, the mean LROC-AUC significantly increased from 0.584 when unaided by VIS/CADe to 0.692 when detection was aided by VIS/CADe (p < 0.01). Radiologists detected 80.0% of cancers with VIS/CADe versus 64.45% of cancers unaided (p < 0.01); specificity decreased from 89.9% to 84.4% (p < 0.01). Radiologist interpretation time significantly decreased by 26%.

CONCLUSION: The VIS/CADe system significantly increased radiologists' detection of cancers and actionable nodules with somewhat lower specificity. With use of the VIS/CADe system, radiologists increased their interpretation speed by a factor of approximately one-fourth. Our study suggests that the technique has the potential to assist radiologists in the detection of additional actionable nodules on thoracic CT.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。