体素内不相干运动MR成像鉴别鼻腔鼻窦良恶性病变:与传统扩散加权MR成像的比较
本研究纳入131例经组织学证实的实性鼻腔鼻窦病变患者(良性56例、恶性75例),评估体素内不相干运动(IVIM)鉴别良恶性病变的价值,并与传统DWI比较。恶性病变的平均ADC值和D值均显著低于良性病变(均P<.001),f值高于良性病变(P=.003);多参数模型较单参数模型可显著提高交叉验证曲线下面积(除D值外,校正P均<.05),D+f模型诊断性能优于ADC值(校正P<.001)。结论认为IVIM在鉴别鼻腔鼻窦良恶性病变方面似乎比传统DWI更有效。
要点
- 恶性鼻腔鼻窦病变的ADC值和D值均显著低于良性病变(均P<.001)。
- 恶性病变的平均f值高于良性病变(P=.003)。
- D+f多参数模型诊断性能优于ADC值(校正P<.001)。
核心结论
- 体素内不相干运动(IVIM)在鉴别鼻腔鼻窦良恶性病变方面似乎比传统DWI更有效。
研究设计与样本
- 本研究纳入131例经组织学证实的实性鼻腔鼻窦病变患者,其中良性56例、恶性75例。
- 所有患者均接受传统DWI和IVIM检查,测量IVIM衍生的扩散系数(D)、假扩散系数(D*)、灌注分数(f)值及传统DWI衍生的ADC值。
- 采用Student t检验比较两组参数,采用受试者工作特征曲线分析、logistic回归分析和10折交叉验证评估单参数和多参数模型的诊断性能。
诊断标准与关键数值
- 恶性鼻腔鼻窦病变的平均ADC值和D值均显著低于良性病变(均P<.001)。
- 恶性病变的平均f值高于良性病变(P=.003)。
- 多参数模型较单参数模型可显著提高鉴别鼻腔鼻窦病变的交叉验证曲线下面积(除D值外,校正P均<.05)。
- D+f模型的诊断性能优于ADC值(校正P<.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Intravoxel incoherent motion is a promising method for the differentiation of sinonasal lesions. This study aimed to evaluate the value of intravoxel incoherent motion in the differentiation of benign and malignant sinonasal lesions and to compare the diagnostic performance of intravoxel incoherent motion with that of conventional DWI.
MATERIALS AND METHODS: One hundred thirty-one patients with histologically proved solid sinonasal lesions (56 benign and 75 malignant) who underwent conventional DWI and intravoxel incoherent motion were recruited in this study. The diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) values derived from intravoxel incoherent motion and ADC values derived from conventional DWI were measured and compared between the 2 groups using the Student t test. Receiver operating characteristic curve analysis, logistic regression analysis, and 10-fold cross-validation were performed to evaluate the diagnostic performance of single-parametric and multiparametric models.
RESULTS: The mean ADC and D values were significantly lower in malignant sinonasal lesions than in benign sinonasal lesions (both P < .001). The mean f value was higher in malignant lesions than in benign lesions (P = .003). Multiparametric models can significantly improve the cross-validated areas under the curve for the differentiation of sinonasal lesions compared with single-parametric models (all corrected P < .05 except the D value). The model of D+f provided a better diagnostic performance than the ADC value (corrected P < .001).
CONCLUSIONS: Intravoxel incoherent motion appears to be a more effective MR imaging technique than conventional DWI in the differentiation of benign and malignant sinonasal lesions.
引用
- Xiao Z, Tang Z, Qiang J, et al. Intravoxel Incoherent Motion MR Imaging in the Differentiation of Benign and Malignant Sinonasal Lesions: Comparison with Conventional Diffusion-Weighted MR Imaging. AJNR Am J Neuroradiol. 2018. PMID: 29371251. doi:10.3174/ajnr.A5532
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。