缺血性卒中患者颈动脉斑块硬度:超音速剪切波成像测量及其与血清同型半胱氨酸水平的相关性
对142例缺血性卒中患者(男76例、女66例,平均66岁)行超音速剪切波成像,测量129个颈动脉斑块的最大、最小和平均剪切波速度(SWV)。回声斑块SWV高于无声回斑块(均p<0.01),斑块硬度与同型半胱氨酸水平呈负相关(r=-0.205至-0.213),SWVmean联合同型半胱氨酸诊断症状性缺血性卒中的AUC为0.67,优于单用同型半胱氨酸的0.60。
要点
- 回声斑块SWVmean为4.29 m/s,无声回斑块为2.09 m/s,回声斑块硬度更高(p<0.01)。
- 斑块SWV与血清同型半胱氨酸水平呈负相关,r值为-0.199至-0.213。
- SWVmean联合同型半胱氨酸诊断症状性缺血性卒中的AUC为0.67,优于单用同型半胱氨酸的0.60。
核心结论
- 超音速剪切波成像可定量评估无声回和回声颈动脉斑块的硬度,斑块SWV与血清同型半胱氨酸水平相关,且与症状性缺血性卒中相关,提示SSI可能有助于理解易损斑块。
研究设计与样本
- 对142例缺血性卒中患者(男76例、女66例,平均年龄66岁,范围45-80岁)行超音速剪切波成像,测量129个颈动脉斑块的最大、最小和平均SWV;以神经系统症状作为易损斑块的替代标志物,行二元logistic回归并计算ROC曲线下面积。
关键影像表现/征象
- 回声斑块(n=51)SWVmin为3.91(3.24-4.17)m/s,无声回斑块(n=78)为1.51(1.04-1.94)m/s,均p<0.01。
- 回声斑块SWVmean为4.29(3.98-4.57)m/s,无声回斑块为2.09(1.69-2.41)m/s,均p<0.01。
- 回声斑块SWVmax为4.67(4.33-4.86)m/s,无声回斑块为2.62(2.32-3.31)m/s,均p<0.01。
诊断标准与关键数值
- Pearson相关分析显示斑块硬度与同型半胱氨酸水平呈负相关,SWVmin、SWVmean、SWVmax的r值分别为-0.205、-0.213、-0.199。
- 二元logistic回归显示性别(p=0.008)、低密度脂蛋白(p=0.015)、甘油三酯(p=0.011)、SWVmean(p=0.004)和高同型半胱氨酸血症(p=0.010)与症状性缺血性卒中显著相关。
- ROC曲线显示SWVmean联合血清同型半胱氨酸水平诊断症状性缺血性卒中的AUC为0.67,优于单用血清同型半胱氨酸的AUC 0.60。
临床应用与阅片要点
- 超音速剪切波成像可定量测量无声回和回声颈动脉斑块的SWV,用于评估斑块硬度。
- 斑块SWV与血清同型半胱氨酸水平呈负相关,并与症状性缺血性卒中相关,提示SSI可能有助于理解易损斑块。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To ascertain the feasibility of using shear wave velocity (SWV) in assessing the stiffness of carotid plaque by supersonic shear imaging (SSI) and explore preliminary clinical value for such evaluation.
MATERIALS AND METHODS: Supersonic shear imaging was performed in 142 patients with ischemic stroke, including 76 males and 66 females with mean age of 66 years (range, 45-80 years). The maximum, minimum, and mean values of SWV were measured for 129 carotid plaques. SWVs were compared between echolucent and echogenic plaques. Correlations between SWVs and serum homocysteine levels were investigated. Based on neurological symptom, the surrogate marker of vulnerable plaque (VP), binary logistic regression was performed and area under curve (AUC) of homocysteine only and homocysteine combing SWVmean was calculated respectively.
RESULTS: Echogenic plaques (n = 51) had higher SWVs than echolucent ones (n = 78) (SWVmin 3.91 [3.24-4.17] m/s vs. 1.51 [1.04-1.94] m/s; SWVmean, 4.29 [3.98-4.57] m/s vs. 2.09 [1.69-2.41] m/s; SWVmax, 4.67 [4.33-4.86] m/s vs. 2.62 [2.32-3.31] m/s all p values < 0.01). Pearson correlation analysis showed that stiffness of plaques was negatively correlated with homocysteine level. R values for SWVmin, SWVmean, and SWVmax were -0.205, -0.213, and -0.199, respectively. Binary logistic regression analysis showed that sex (p = 0.008), low-density lipoprotein (p = 0.015), triglycerides (p = 0.011), SWVmean (p = 0.004), and hyper-homocysteinemia (p = 0.010) were significantly associated with symptomatic ischemic stroke. Receiver operating characteristic curves revealed that SWVmean combing serum homocysteine level (AUC = 0.67) presented better diagnostic value than serum homocysteine only (AUC = 0.60) for symptomatic ischemic stroke.
CONCLUSION: Supersonic shear imaging could be used to quantitatively evaluate stiffness of both echolucent and echogenic carotid plaques. More importantly, SWVs of plaques were not only correlated to serum homocysteine level, but also associated with symptomatic ischemic stroke, suggesting that SSI might be useful for understanding more about VP.
引用
- Shang J, Wang W, Feng J, et al. Carotid Plaque Stiffness Measured with Supersonic Shear Imaging and Its Correlation with Serum Homocysteine Level in Ischemic Stroke Patients. Korean J Radiol. 2018. PMID: 29353995. doi:10.3348/kjr.2018.19.1.15
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。